FR
Phase One logo
Notice d'utilisation officielle

Phase One H 10 M645

15 pages·1.4 MB·Appareil photo numérique·PDF·EN
Phase One H 10 M645
Table des matières 10 sections H 10 M645 · GETTING STA RT E D · 1 Introduction · 2 Special H 10 M645 features · … AfficherMasquer
Page 1 of the Phase One H 10 M645 user manual — H 10 M645
Page 1 · cliquer pour agrandir
Page 1

H 10 M645

GETTING STA RT E D

Phase One A/S Roskildevej 39 DK-2000 Frederiksberg Denmark Tel +45 36 46 01 11 Fax +45 36 46 02 22

Phase One U.S. 24 Woodbine Ave Northport, New York 11768 USA Tel +00 631-757-0400 Fax +00 631-757-2217

Page 2 of the Phase One H 10 M645 user manual — H 10 M645
Page 2 · cliquer pour agrandir
Page 2

The name Phase One is a trademark of Phase One A/S.

The names Apple Macintosh, Mamiya, Microsoft Windows and Adobe

Photoshop are all registered trademarks of their respective companies.

All specifications are subject to change without notice.

Phase One takes no responsibility for any loss or damage sustained while using

their products.

This manual ©2002, Phase One A/S Denmark. All rights reserved. No part of

this manual may be reproduced or copied in any way without prior written per-

mission of Phase One.

Printed in Denmark.

Part #80013001
Page 3 of the Phase One H 10 M645 user manual — H 10 M645
Page 3 · cliquer pour agrandir
Page 3
Page 3 of the Phase One H 10 M645 user manual — H 10 M645
Page 4 of the Phase One H 10 M645 user manual — 1 Introduction
Page 4 · cliquer pour agrandir
Page 4

1 Introduction

The H 10 for M645 is a single shot digital camera back for the innovative Mamiya 645 AFD camera. The Mamiya 645 utilises a hybrid TTL phase-difference-detection type auto- focus system. Further more the Mamiya 645AF provides auto exposure settings. The Mamiya 645AFD with a H 10 M645 back encourages all kinds of photographic uses from portraiture and wide-angle photography to high speed shooting to capturing fast action with telephoto lenses. This exiting combination is a result of a joint development project between Phase One and Mamiya-OP.

The functionality of the H 10 M645 is well integrated with the Mamiya 645AFD camera. The H 10 M645 camera back communicates with the Mamiya camera through a fast inter- nal electrical computer interface.

The H 10 M645 is based on the highly recognised Phase One camera back technology. The application software for the H 10 M645 is the same as for all other Phase One single shot products. The Capture One User Guide is a general manual for these products. This Manual “H 10 M645 - Getting Started” covers only specific H 10 M645 features and func- tionality.

Page 5 of the Phase One H 10 M645 user manual — 2 Special H 10 M645 features
Page 5 · cliquer pour agrandir
Page 5

2 Special H 10 M645 features

The Mamiya 645AFD can work in different auto exposure modes. This is fully supported by the H 10 M645, which com- municates the equivalent film speed of the digital back to the Mamiya 645AFD camera.

The default film speed of the H 10 M645 camera back is ISO 50. However this setting can be changed to 100, 200 or even 400 ISO, inside the Capture One application.

Phase One H 10 M645 — 2 Special H 10 M645 features diagram (page 5)
Fig. 1 · 2 Special H 10 M645 features

It is recommended to capture images using a film curve. That is done by selecting the film curve in the Capture One software. Click the camera icon in the icon bar, and select “Film Curve” or “Film Curve, Natural Black”.

When capturing with auto exposure modes, exposures be- tween 1/4000 sec. and 30 sec can be obtained. Please note that images captured with exposure times longer than 2 sec. can be degraded because of increased digital noise.

Auto exposure

Page 6 of the Phase One H 10 M645 user manual — 2 Special H 10 M645 features
Page 6 · cliquer pour agrandir
Page 6

When using the M645 with a H 10 M645 it is not possible to accidently double expose the image by capturing one image quickly after another. The H 10 communication with the M645 is disabling capture functionality in the camera when necessary.

At the end of an image exposure the image information in the CCD has to be moved from the CCD to the host com- puter. During this short period of time the CCD must be pro- tected from light exposure. The H 10 M645 ensures a safe emptying of the CCD by ignoring the shutter release from the Mamiya camera.

The CCD in H 10 M645 is positioned in landscape orienta- tion. Whenever an image is captured in portrait position by rotating the camera, an internal sensor detects this new po- sition and the image will appear as a correctly oriented im- age in the Capture One application.

Phase One H 10 M645 — 2 Special H 10 M645 features diagram (page 6)
Fig. 2 · 2 Special H 10 M645 features
Phase One H 10 M645 — 2 Special H 10 M645 features diagram (page 6)
Fig. 3 · 2 Special H 10 M645 features

Camera orientation: Images can be captured in all three positions - and will appear with the correct orientation in the Capture One software.

Double exposure protection · Image orientation detection

Page 7 of the Phase One H 10 M645 user manual — 2 Special H 10 M645 features
Page 7 · cliquer pour agrandir
Page 7

IR filter on the CCD

The IR filter (Phase One TG1 Infrared cut-off filter) is placed on top of the CCD.

The filter may not be removed for several reasons.

l The focusing of the H 10 camera back will be damaged

l It is only possible to remount the filter without dust in between the filter and the CCD if you have access to special clean room facilities.

l The Phase One Product Warranty is terminated.

Page 8 of the Phase One H 10 M645 user manual — 3 Getting ready for taking pictures
Page 8 · cliquer pour agrandir
Page 8

3 Getting ready for taking pictures

Mounting the viewfinder mask

The image area of the Mamiya 645AF is approximately 6 cm x 4.5 cm. The image area of the H 10 M645 is 2.4 cm x 3.6 cm. A H 10 M645 viewfinder mask is provided. This mask has to be mounted beneath the original focusing screen. The viewfinder mask is positioned in the bracket that holds the focusing screen. Please refer to the Mamiya 645 AFD In- structions “Changing the focus screen” before the focus screen is mounted.

Phase One H 10 M645 — 3 Getting ready for taking pictures diagram (page 8)
Fig. 4 · 3 Getting ready for taking pictures
Phase One H 10 M645 — 3 Getting ready for taking pictures diagram (page 8)
Fig. 5 · 3 Getting ready for taking pictures

The black mark on the mask must be orien- tated to the left front corner of the bracket.

Page 9 of the Phase One H 10 M645 user manual — 3 Getting ready for taking pictures
Page 9 · cliquer pour agrandir
Page 9

Mounting the H 10 M645 on the Mamiya 645AFD

The H 10 M645 is fully integrated with the camera house and acts as a true part of the whole camera system.

When no cassette is attached to the Mamiya 645 AF camera house the mirror is up and the shutter is open. This is the correct position, when no film cassette is attached.

When attaching the M645 to the camera house, the shutter will close and the mirror comes down.

It is important to ensure that the bottom part of the H 10 M645 camera back is pressed well into the locking mecha- nism before the upper locking mechanism is pressed to- gether. Failure to do this can in some circumstances bring the Mamiya camera house in an error state of continuos opening and closing the shutter. (The same procedure is rec- ommended for all film cassettes).

In case this error appears you simply have to remove the H 10 M645. Notice if the shutter is in the closed position, at- tach and remove the H 10 to make sure that the camera house gets in the correct starting position.

To avoid that the H 10 is released by mistake from the cam- era house, you can use the enclosed screwdriver to lock the H 10 M645 locking mechanism.

Step 1 Step 3 Step 2

Page 10 of the Phase One H 10 M645 user manual — NOT CORRECT
Page 10 · cliquer pour agrandir
Page 10

Using auto focus lenses:

Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 6

No cables are required be- tween the H 10 M645 and the Mamiya 645AFD when auto focus lenses are used.

Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 7

Flash sync cable must be connected to the Mamiya 645AFD camera house.

Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 8

CORRECT

Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 9
Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 10
Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 11

When using AF lenses the flash sync cable must NOT be connected to the camera back.

Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 12
Phase One H 10 M645 — CORRECT diagram (page 10)
Fig. 13

NOT CORRECT

Use of cables

Page 11 of the Phase One H 10 M645 user manual — CORRECT
Page 11 · cliquer pour agrandir
Page 11
Using manual focus lenses: The provided short flash sync cable shall be connected between the “C” plug on the H 10 M645 and the lens sync plug. The flash system sync cable shall be connected to the H 10 M645 “F” plug. Only exposure times between 1/250 sec. and 30 sec. are supported. When using a manual-focus lens in continuous light you must manually compensate for a small underexposure i.e. with the setting of the aperture: Exposure time Loss in exposure 1/60 sec 1/3 f-stop 1/125 sec 1/2 f-stop 1/250 sec 1 f-stop Operating the camera from the host computer: The supplied motor cable must be connected between the “M” connector on the H 10 M645 and the 8-pin connector on the Mamiya camera house. AF-lenses as well as manual focus lenses can be used. 9
Phase One H 10 M645 — CORRECT diagram (page 11)
Fig. 14
Page 12 of the Phase One H 10 M645 user manual — 4 Maintenance
Page 12 · cliquer pour agrandir
Page 12

4 Maintenance

Cleaning the IR filter

When the H 10 M645 camera back is not attached to a Mamiya camera, the camera back shall be protected with the protection plate. Still dust particles can stick to the IR fil- ter. This will degrade the image quality.

The cleaning procedure for cleaning the IR filter is described in the guidelines for the CCD cleaning kit that came with your camera back.

Cleaning between the CCD and the IR filter

Do not try to clean between the CCD and the IR filter!

The mounting of the IR filter is done at the factory in a high- class clean room. This process is a very specialised process that insures an extremely high quality of the glass surfaces of the CCD and the IR filter. The screws for locking the IR filter are sealed. If the seal is broken Phase One will not guarantee for any particles between the CCD and the IR filter.

Page 13 of the Phase One H 10 M645 user manual — 5 Current limitations
Page 13 · cliquer pour agrandir
Page 13

5 Current limitations

Continuous capture mode will work as single exposure mode. Keeping the release bottom down will only result in one exposure. The release button has to be depressed be- tween exposures.

Continuous capture mode

Page 14 of the Phase One H 10 M645 user manual — 6 Technical data
Page 14 · cliquer pour agrandir
Page 14

6 Technical data

l Single shot camera back for Mamiya 645AFD

l Electrical computer interface between H 10 M645 and Mamiya 645AFD

l Full support for Mamiya lenses (1/4000 - 30 sec.)

l Electronic protection against double exposure

l Orientation sensor for correct display of landscape and portrait images

Resolution3992 x 2656 pixels
Image modesRGB, Grey or CMYK

Pixel depth: 3 x 8 bit or 3 x 16 bit for RGB 8 bit or 16 bit for Grey 4 x 8 bit or 4 x 16 bit for CMYK

Image area24.6 mm x 36.9 mm (1” x 1.5”)
Computer connectionIEEE 1394
Power consumption7 watt
Compatible strobe systemsWhen using Auto-Focus

lenses, please refer to the Mamiya documentation.

Page 15 of the Phase One H 10 M645 user manual — 6 Technical data
Page 15 · cliquer pour agrandir
Page 15
Page 15 of the Phase One H 10 M645 user manual — 6 Technical data

Poser une question sur : Phase One H 10 M645

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Phase One H 10 M645

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Phase One H 10 M645 manuel PDF

15 pages·1.4 MB·Appareil photo numérique·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…