DPoE ™ Power System User Manual Copyright © 2007 PANDUIT Corp. All rights reserved. No part of this book shall be repr oduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording or otherwise, without written permission from PANDUIT .
DP O E™ Power System User Manual Part Number: PN380C ii SAFETY WARNING The DP O E™ Power Patch Panel Power System is for use in re stricted access locations o nly. It is suitable for mounting on concrete or other non-combustible surfaces. Always observe standard safety precautions durin g installation, operation and maintenance of this product.
DP O E™ Power System User Manual Part Number: PN380C iii The remedies provided herein are Buye r's sole and exclu sive remedies. PANDUIT Corp. shall not be liable for any direct, indirect, special, inci dental or consequential da mages, whether base d on contract, tort or other legal theory.
DP O E™ Power System User Manual Part Number: PN380C iv TABLE OF CONTENTS SAFETY WARNING ..................................................................................................................... ii FCC Compliance Statement ..........
DP O E™ Power System User Manual Part Number: PN380C v Table 4: Recommended AC Circuit Breaker and Wire Sizes ........................................................ 4 Table 5: Minimum Recommended DC AWG for 90°C Cabling for Unprotected Outputs .
DP O E™ Power System User Manual Part Number: PN380C OVERVIEW The DP O E™ Power Patch Panels a nd the DP O E™ Compact 8 Mids pan provide a reliable and cost- effective solution for Power over Ethernet (PoE) applications, complaint with the IEEE 802.
DP O E™ Power System User Manual Part Number: PN380C 2 INSTALLATION CAUTION: Observe all local and national electrical, environmenta l, and workplace codes.
DP O E™ Power System User Manual Part Number: PN380C 3 Table 2: DP O E™ Power Components Available from PANDUI T PANDUIT Part Number Description DPOEPWRB120Y Individual power supply - 120 watt pow.
DP O E™ Power System User Manual Part Number: PN380C Rec t i f i e r s 12 3 Feed 1 Feed 2 AC In N+1 DC Out Feed 3 Figure 2: Individual AC F eed Wiring Architecture Each individual AC feed should be prote cted using a circuit breaker as list ed in Table 4: Recommended AC Circuit Breaker and Wire Sizes .
DP O E™ Power System User Manual Part Number: PN380C CAUTION: ALWAYS FOLLOW NEC GUIDELINES AND YOUR LOCAL COMPANY PRACTICES WHEN SELECTING DC WIRING AND PROTECTION. Table 5: Minimum Recommended DC AWG for 90°C Cabling for Unprotecte d Outputs shows recommended wire sizes base d on ampacity.
DP O E™ Power System User Manual Part Number: PN380C Butt spl i ces con nect or s P o w e r c o n n ec to r housi ng wit h w i r e l eads 48VD C Suppl y Pow er Connect o r on r ear s i de of DP O E.
DP O E™ Power System User Manual Part Number: PN380C 7 Torque Settings The following table shows recomme nded torque settings for all me chanical and electrical con nections according to screw or nut size in inch pound s (in-lbs).
DP O E™ Power System User Manual Part Number: PN380C POWER PLANT MOUNTING AND WIRING WARNING: Ensure all AC and DC power sources are off and disconnected. 8 Mechanical Mounting The DP O E™ Power System chassis is i nstalled in a st andard EIA 19” rack.
DP O E™ Power System User Manual Part Number: PN380C AC Input Slip the cord bracket around each cord ( PANDUIT part # CORD-****), as sho wn in Figure 7: Cord Bracket .
DP O E™ Power System User Manual Part Number: PN380C The DP O E™ Power System Chassi s allows a bulk DC conne ction as shown in Figure 12: Chassis (Rear View) - DC Connections .
DP O E™ Power System User Manual Part Number: PN380C TEST AND TURN-ON Once all AC and DC connections have been se cured and checked, install each re ctifie r sequentially by sliding and latching it into the chassi s as illustrated in the section below.
DP O E™ Power System User Manual Part Number: PN380C 12 TROUBLESHOOTING The modular nature of this DP O E™ Power System m akes diagnostics and rep air easy. Make sure that all rectifiers are properly seat ed and latched into their respective slot s.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Panduit PN380C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Panduit PN380C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Panduit PN380C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Panduit PN380C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Panduit PN380C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Panduit PN380C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Panduit PN380C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Panduit PN380C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.