FR
Panasonic logo
Notice d'utilisation officielle

Panasonic Remote Controller (CZ-RE2C2)

50 pages·1.6 MB·Télécommande·PDF·ENNLJA
Panasonic Remote Controller (CZ-RE2C2)
Table des matières 7 sections 1. Important Safety Instructions · Warning ・ Do not wipe the remote controller with · 2. Names and Operations · Operation Section · … AfficherMasquer
Page 2 of the Panasonic Remote Controller (CZ-RE2C2) user manual
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Panasonic Remote Controller (CZ-RE2C2) user manual
Page 3 of the Panasonic Remote Controller (CZ-RE2C2) user manual — Warning ・ Do not wipe the remote controller with
Page 3 · cliquer pour agrandir
Page 3

1. Important Safety Instructions

Before using the system, be sure to read these “Important Safety Instructions”. After reading this manual, save it in a convenient place.

Warning ・ Do not wipe the remote controller with

benzine, thinner, or chemical cloth. Note: ・ This device complies with Part 15 of the FCC

*Installation Precautions ・Do not install by yourself. Installation should always be performed by your dealer or a professional service provider. Electric shock or fire may result if an inexperienced person performs any installation or wiring procedures incorrectly. ・Use only specified air conditioners.

Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ・ This equipment has been tested and found to

Always use only air conditions specified by the dealer. *Moving and Repair Precautions ・Do not repair. Never repair the system by yourself. ・Contact your dealer before moving the system.

comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfer- ence by one or more of the following measures: ・ Reorient or relocate the receiving antenna. ・ Increase the separation between the

Contact your dealer or a professional service provider about moving and reinstalling the system. Electric shock or fire may result if an inexperienced person performs any installation procedures incorrectly. *Precautions for Use ・Do not touch switches with wet hands.

Electric shock and damage to the system can result. ・Protect the remote controller from water.

Damage to the system can result. ・Stop the system and turn the power off if you

sense unusual smells or other irregularities. Continuing operation when the system is out of order can result in electric shock, fire,and damage to the system. Contact your dealer. ・Do not turn the air conditioner on and off from

equipment and receiver. ・ Connect the equipment into an outlet on a

circuit different from that to which the receiver is connected. ・ Consult the dealer or an experienced

the power mains switch. Use the ON/OFF operation button. ・Do not stick anything into the air outlet of the

radio/TV technician for help. ・ FCC Caution: To assure continued compliance,

air conditioner. Doing so is dangerous because the fan is rotating at high speed. ・Do not let children play with the air conditioner. ・Do not cool or heat the room too much if

follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

babies or invalids are present.

Page 4 of the Panasonic Remote Controller (CZ-RE2C2) user manual — Operation Section
Page 4 · cliquer pour agrandir
Page 4

2. Names and Operations

Operation Section

1. (Start/Stop) button Pushing this button starts, and pushing again stops the unit.
6. (Outing function) button
2. (Temperature setting) buttons Changing the temperature setting.
Panasonic Remote Controller (CZ-RE2C2) — Operation Section diagram (page 4)
Fig. 1 · Operation Section
3. (Mode Select) button Pushing this button to select an operation mode. (AUTO → HEAT → DRY → COOL → FAN ).
Panasonic Remote Controller (CZ-RE2C2) — Operation Section diagram (page 4)
Fig. 2 · Operation Section
4. (Fan speed) button Changing the fan speed. ( / / / )
5. (Swing/Air direction) button *1 Use this button to set the auto swing or air direction to a specific angle.
Panasonic Remote Controller (CZ-RE2C2) — Operation Section diagram (page 4)
Fig. 3 · Operation Section

*1 Do not move the flap (vertical airflow adjustment board) with your hand. ・The flap is automatically directed down when the unit is stopped. ・The flap is directed up during the HEAT standby. The flap starts swinging after the HEAT standby is cancelled, although the AUTO flap indication on the remote control unit is displayed during the HEAT standby.

( Outing Function)

Page 5 of the Panasonic Remote Controller (CZ-RE2C2) user manual — Display Section
Page 5 · cliquer pour agrandir
Page 5

Display Section

1. (Fan mode select) indication The selected fan mode is displayed.
10. (Centralized control) indication Appears when operated in centralized control. If the remote control operation is not permitted to the remote unit, when the (Start/Stop) button, (Mode select) button, (Fan speed) button, (Swing/Air direction) button or (Temperature setting) buttons are pressed, flashes and rejects the change.
2. (Flap position) indication Indicates the flap position.
3. (Swing) indication Appears while the flap swings.
4. (Outing) indication ( Outing Function) Appears when the outing function is set.
11. (Disabled feature) indication Displayed if the selected feature was disabled during installation.
5. Operation Mode indication Displays the selected operation mode. (AUTO /HEAT /DRY /COOL / FAN ).
12. (Heating standby mode) indication appears when the fan of the indoor unit is stopped or in low fan speed.
6. Upper and lower limit indication of the outing function : Indicates the upper limit of the temperature : Indicates the lower limit of the temperature
13. (Caution) indication Appears when the protective device is activated or when an abnormality occurs.
14. Alarm indication This displays alarm messages when an error occurs.
7. Temperature indication Indicates the set temperature.
15. (Oil) indication Appears when the engine oil needs to be changed. (Appears when the gas heat pump air conditioner is used.)
8. °F / °C (Temperature unit)indication
9. (Remote control sensor) indication Appears when the remote control sensor is used.

/ / /

Page 6 of the Panasonic Remote Controller (CZ-RE2C2) user manual — General Performance of the Outing Function
Page 6 · cliquer pour agrandir
Page 6

3. Outing Function

Outing function is a function that prevents the room temperature from increasing too much (or decreasing too much) when no one is in the room. An air conditioner works automatically if this function is set effective.

General Performance of the Outing Function

Panasonic Remote Controller (CZ-RE2C2) — General Performance of the Outing Function diagram (page 6)
Fig. 4 · General Performance of the Outing Function

① The air conditioner starts operation when the room temperature increases up to –1°C of the upper limit. ② The air conditioner stops operation when the room temperature decreases up to –2°C of the upper limit.

① The air conditioner starts operation when the room temperature decreases up to +1°C of the lower limit. ② The air conditioner stops operation when the room temperature increases up to +2°C of the lower limit.

[Precautions] ・The outing control only starts/stops the air conditioner. It does not change the operation mode/ temperature setting. Therefore, the operation mode/temperature needs to be set beforehand so that the outing function turns on the air conditioner with your desired operation mode/ temperature setting. ・If the room temperature rapidly changes, the room temperature may get over the upper or lower limit when the outing function is activated. ・The outing function is invalid during FAN/AUTO operation mode. ・The air conditioner’s stop order (stated in ② ⁄ above) is valid only when the outing function is operated.

If operated using other remote control units (or a centralized control device such as a system control), the outing function will not stop air conditioner operation.

Page 7 of the Panasonic Remote Controller (CZ-RE2C2) user manual — 3. Outing Function
Page 7 · cliquer pour agrandir
Page 7
3. Outing Function (Continued)
  • Setting the Outing Function

1.Press and hold for more than 4 seconds to display the upper limit temperature setting screen., and the upper limit temperature start flashing. (The default value of the upper limit temperature is 38 °C.)

2.Press / to select the upper limit temperature, and press to fix the value. The lower limit temperature setting screen is displayed.

Panasonic Remote Controller (CZ-RE2C2) — 3. Outing Function diagram (page 7)
Fig. 5 · 3. Outing Function

3.Press / to select the lower limit temperature, and press to fix the value. The outing function setting is completed. (The default value of the lower limit temperature is 10 °C.) *The unit returns to the normal mode if is pressed or there is no operation made for 3 minutes during the setting. In this case, all the settings in progress will be lost.

  • Canceling the outing function

Press and hold for more than 4 seconds while the outing function is set.

  • Outing function indication
Panasonic Remote Controller (CZ-RE2C2) — 3. Outing Function diagram (page 7)
Fig. 6 · 3. Outing Function
Outing function indicationStatus OffThe outing function is not set. FlashingThe outing function is now being set, or under operation. LightingAlthough the outing function is set, not under operation.

Poser une question sur : Panasonic Remote Controller (CZ-RE2C2)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Panasonic Remote Controller (CZ-RE2C2)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Panasonic Remote Controller (CZ-RE2C2) manuel PDF

50 pages·1.6 MB·Télécommande·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%