Manuel d'utilisation / d'entretien du produit PS L02A du fabricant Oregon Scientific
Aller à la page of 28
EN Full Weather Stat ion with Radio Cont rolled Clock and Project ion ( Model #:PS L02A) User Manual PS-L02A English Cover r8 op 2/13/04, 10:45 AM 1 Black.
EN 1 T ABLE OF CONTENTS About this guide ........................................................ 2 Product overview ....................................................... 3 Getting started .......................................................... 8 Batteries .
EN 2 ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full W eather Station with Radio Controlled Clock and Projection (PS L02A).
EN 3 PRODUCT OVERVIEW TOP VIEW DESCRIPTIONS 1. Snooze/Light and Projection Button 2. Light sensor 3. Projection lens 1 2 3 PS-L02A English r8 op 2/13/04, 12:28 PM 3 Black.
EN 4 LCD DISPLA Y DESCRIPTIONS 1. Low batteries icon 2. Clock 3. Barometer 4. W eather forecast 5. Moon phase 6. Calendar 7. T emperature and humidity 8.
EN 5 BACK VIEW BUTTON DESCRIPTIONS 1. Focus – focus projector 2. Select – switch modes / change settings 3. Rotation – rotate projector 4. Up – increase setting / activate auto-synch 5. Down – decrease setting / deactivate auto-synch 6. Alarm –activate / deactivate alarm 7.
EN 6 BOTTOM VIEW DESCRIPTIONS 1. Battery compartment 2. Light sensitivity knob 3. Reset button 4. Backlight switch 5. DC power input jack NO TE AC power adapter not shown.
EN 7 REMOTE UNIT DESCRIPTIONS 1. T emperature / T rend display 2. Low battery icon 3. Humidity / T rend / Comfort Level display 4. ° F / ° C switches 5.
EN 8 GETTING ST ARTED BA TTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries.
EN 9 SWITCH BETWEEN MODES Press SELECT . The select mode will flash. The display will stop flashing if no key is pressed within 5 seconds. CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options.
EN 10 • Position the unit so that it faces the main (indoor) unit. Minimize obstructions such as doors, walls, and furniture. Y ou may need to experiment with various locations to get the best reception. CLOCK This product can automatically synchronize the date and time with the US Atomic Clock.
EN 11 TO DISABLE OR ENABLE AUTO- SYNCHRONIZA TION In Clock mode, press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. To enable auto-reception, press UP for 2 seconds.
EN 12 SNOOZE Press the SNOOZE/LIGHT button the top of the unit to temporarily disable the alarm for 8 minutes. The alarm icon will blink while Snooze is activated. TO TURN THE ALARM OFF OR ON Press any button to stop the alarm. To turn the alarm off completely (deactivate it for the next day), press ALARM .
EN 13 BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast ( → pg.14) and a trend line showing the direction of barometric change. Barometric changes are measured by the main (indoor) unit.
EN 14 SET UNIT AND AL TITUDE Y ou can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take more accurate barometric measurements. 1. Press SELECT 2 times until the Barometer Area flashes. 2. Press and hold SELECT for 2 seconds.
EN 15 Outdoor measurements are collected by the remote unit. T emperature is give at the top; humidity is below . VIEW MIN / MAX / CURRENT MEASUREMENTS Press SELECT 3 times until the T emperature and Humidity Areas flash. Press UP or DOWN to scan the readings.
EN 16 NO TE Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failures between the indoor and outdoor units. This is normal and does not affect the general performance of the product.
EN 17 TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately . SET UNIT While in T emperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between ° F and ° C.
EN 18 2. Move it to the “AUTO” position to enable continuous backlight controlled by light intensity . When activated, the backlight will be on whenever the unit perceives that the room is dark. 3. The Light Sensitivity knob is located in the battery compartment.
EN 19 ROT A TE IMAGE The ROT A TION switch is located on the back of the unit. Rotate to adjust. FOCUS IMAGE The FOCUS switch is located on the back of the unit. Rotate to adjust. CONTINUOUS PROJECTION The AC power adapter must be plugged in to use this feature ( → pg.
EN 20 SAFETY AND CARE Clean the unit with a slightly damp cloth and mild detergent. Avoid dropping the unit or placing it in a location where the AC power adapter will be stepped on. W ARNINGS This product is designed to give you years of service if handled properly .
EN 21 TROUBLESHOOTING Problem Symptom Remedy Remote unit Cannot locate remote unit Check batteries ( → pg.8) Check location ( → pg.9) Cannot change channel Check sensors. Only one sensor is working ( → pg.15 ) Clock Cannot auto- synchronize Make sure auto- synchronization is enabled ( → pg.
EN 22 SPECIFICA TIONS Main unit dimensions L x W x H 7.1 x 1.77 x 7.3 inches (181 x 45 x 185.3 mm) W eight 2.02 lbs / 914 grams with battery Remote unit dimensions L x W x H 3 x 1.4 x 3.1 inches (75 x 35 x 78.3mm) W eight 0.3 lbs / 136 grams with battery Problem Symptom Remedy 3.
EN 23 T emperature Unit ° F or ° C Range Main unit: 23 ˚F to 122 ˚F (-5 ˚C to 50 ˚C) Remote Unit: -4 ˚F to 140 ˚F (-20 ˚C to 60 ˚C ) Resolution 0.2 ° F (0.1 ° C) Comfort 68 ° F to 77 ° F (20 ° C to 25 ° C) (see also, Relative humidity) Memory Minimum / maximum Tr end +/- 0.
EN 24 Remote unit RF frequency 433 MHz Range 98 feet (30 meters) with no obstructions T ransmission approximately every 40 seconds Channel No. 1, 2, or 3 Unit ° F or ° C Radio-controlled clock Synch.
EN 25 ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about other Oregon Scientific TM products such as digital cameras, projection clocks, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach us.
EN 26 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be det.
EN 27 CAUTION — The content of this manual is subject to change without further notice. — Due to printing limitation, the displays shown in this manual may differ from the actual display. — The contents of this manual may not be reproduced without the permission of the manufacturer.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Oregon Scientific PS L02A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Oregon Scientific PS L02A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Oregon Scientific PS L02A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Oregon Scientific PS L02A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Oregon Scientific PS L02A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Oregon Scientific PS L02A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Oregon Scientific PS L02A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Oregon Scientific PS L02A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.