Manuel d'utilisation / d'entretien du produit OS530L du fabricant Omega Engineering
Aller à la page of 78
OS5 31, OS5 32, OS53x-CF , OS5 33, OS5 34, OS530L, OS530HR OS523, OS524 OMEGASCOPE ® Handheld Inf r ar e d The r m om e t er Shown with Built-in Laser Sighting TM omega.
Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
Unpacking Instructions n4 Notes.
i Unpacking Instructions NOTE Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses): • OS530/OS520 Series Handheld Infrared The.
ii.
TABLE OF CONTENTS Page Unpacking Instructions i Chapter 1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1 Introduction 1-1 1.2 Parts of the Thermometer 1-4 1.2.1 Front of the Thermometer 1-4 1.2.2 Rear of the Thermometer 1-6 Chapter 2 Using the Handheld Infrared Thermometer .
iv Appendix A How Infrared Thermometry Works . . . . . . . . . . . . . A-1 Appendix B Emissivity Values . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Appendix C Determining an Unknown Emissivity . . . . . . . . . . . . C-1 Index . . . . . .
1-1 General Description 1 1.1 Introduction The OS530/OS520 series Handheld Infrared (IR) Thermometers provide non-contact temperature measurements up to 4500°F.
General Description 1 1-2 The thermometer is easy to use: • Units have standard “V” groove aiming sights. • Integral tripod mount permits hands-free operation, if necessary. • Temperature readings are switchable from °F to °C via the keypad.
1-3 General Description 1 Features OS530L OS530HR OS530L-CF OS533-CF OS534-CF Accuracy* ±1% rdg 3°F (1.7 °C) ±1% rdg ±1% rdg ±1% rdg Range -18 to 538°C -30 to 121°C -18 to 538°C -18 to 538°C.
General Description 1 1-4 Distance to Spot Size Ratio OS523-1 30:1 OS523-2 60:1 OS523-3 68:1 * * OS523 provides three field of views: Features OS523 ** OS524 Accuracy ±1%rdg ±1% rdg Range 0 to 2500.
1.2 Parts of the Thermometer 1.2.1 Front of the Thermometer Figure 1-1. OS530/OS520 Series Handheld Infrared Thermometer Front View The display is shown in more detail in Figure 1-2 and described in Table 1-2. There are no user-serviceable parts in the thermometer.
General Description 1 1-6 Figure 1-2. Display and Keypad View Table 1-2. Display Details Key Description ➀ Display Mode displays one of the following: TC (Thermocouple Input) E (Emissivity) HAL (Hig.
1-7 General Description 1 1.2.2 Rear of the Thermometer Figure 1-3 shows the various jacks that are used to connect a recorder or the ac adapter to the thermometer. The figure also shows the location of the tripod thread mount used for fixed point monitoring.
General Description 1 1-8 Notes.
2-1 Using the Handheld Infrared Thermometer 2 2.1 How to Power the Thermometer 2.1.1 Battery Operation Invert the thermometer and install 4 fresh AA size batteries as shown in Figure 2-1. Make sure the batteries’ polarities are correct, the batteries are not put in backwards, and are of the same type.
Using the Handheld Infrared Thermometer 2 2-2 2.2 Operating the Thermometer 1a. (Without the Laser Sighting) -Aim the thermometer at the target to be measured. Use the “V” groove (shown in Figure 1-1) on top of the thermometer to align the target to the thermometer’s field of view.
Figure 2-4. Field of View OS531, OS532, OS530L Figure 2-5 Field of View OS533, OS530HR 2-3 Using the Handheld Infrared Thermometer 2 SPOT DIA. * (IN) SPOT DIA. * (CM) ** Measurement distance is from the outside surface of the rubber boot. 4.8" 1.
Using the Handheld Infrared Thermometer 2 2-4 Figure 2-6 Field of View OS534, OS523-1 Figure 2-7 Field of View OS53x-CF .45" 11.5 3" SPOT DIA.* (MM) *SPOT DIAMETER MEASURED AT 90% ENERGY 7.6 SPOT DIA.* (IN) DISTANCE: SENSOR LENS TO OBJECT (in.
2-5 Using the Handheld Infrared Thermometer 2 Figure 2-8 Field of View OS523-2 Figure 2-9 Field of View OS523-3 2. 9 " 0. 9 "@ 0 1. 9 " 22mm @ 0 1.2" 1.0" 31 26 48 75 0. 9 " 0' 3' 16' 10' *SPOT DIAMETER MEASURED AT 9 0% ENERGY D:S = 60:1 5' 5.
Using the Handheld Infrared Thermometer 2 2-6 Figure 2-10 Field of View OS524 3. The target temperature and emissivity are displayed on the LCD. Determine the emissivity of the target (refer to Appendix B). Press the key to increment the target emissivity.
2.2.1 Measurement Techniques You can use the IR Thermometer to collect temperature data in any one of five different ways: • Spot Measurement — Measures the temperature of discrete objects such as motor bearings, engine exhaust manifolds, etc.: 1.
Using the Handheld Infrared Thermometer 2 2-8 Figure 2-11 Recorder Hookup • Moving Surface Scan - Measures the Temperature of Points on a Moving Surface: 1. Mount the thermometer on a camera tripod and aim at a fixed point on the moving surface. 2. Pull the trigger and press the key to lock the trigger.
2-9 Using the Handheld Infrared Thermometer 2 2.3 Real Time Mode (Active Operation) Definition: Real T ime Mode is the active operational mode of the thermometer . In this mode, the thermometer constantly measures and displays temperatur e. Figure 2-12.
Table 2-1. Functional Flow Chart when the Trigger is Pulled (Real Time Mode) DISPLAY MODE: Press to... Go to Go to Go to Go to Go to Go to or Go to Go to or Go to Go to Press to.
Figure 2-13. Visual Function Flow Chart LCK LAL ATC PRN HAL MODE MODE DISPLA Y DISPLA Y ☞ ☞ ☞ ☞ ☞ ☞ ☞ ☞ ☞ ☞ ☞ LCK LCK LCK LCK LCK LCK LCK LCK LCK LCK (Model OS533) LCK (Model OS531, OS532 OS530L, OS530HR) * While in these 5 modes: Use key to change temperature from °F to °C or vice versa.
2.3.1 Adjusting Emissivity Refer to Appendices B and C for information on emissivity. 1. Determine the emissivity of the target. 2. Aim at the target and pull the trigger. 3. If necessary, press the key to increment the target emissivity or press the key to decrement the target emissivity.
2.3.3 Calculating Temperature Values The thermometer calculates the MAX, MIN, dIF, and AVG temperatures based on the current temperature. To clear the “AVG ---” display, turn off the thermometer.
2.3.6 Thermocouple Input (OS532, OS533, OS534) The thermometer accepts thermocouple input. It displays thermocouple temperature and the target temperature (via infrared) simultaneously. This function provides an accurate method of determining an unknown emissivity.
2.3.7 Using the Alarm Functions The thermometer provides audible and visible alarm indications. • To set the high alarm value : 1. Pull the trigger. Then press and hold the key until the High Alarm Display Mode (HAL) appears. 2. Press the key to increment the high alarm value.
NOTE ° F LAL Using the Handheld Infrared Thermometer 2 2-16 • To set the low alarm value: (OS533, OS534, OS523, OS524): 1. Pull the trigger. Then press and hold the key until the Low Alarm Display Mode (LAL) appears. 2. Press the key to increment the low alarm value.
2.3.8 Using Ambient Target Temperature Compensation (OS533, OS534, OS523, OS524) Use the Ambient Target Temperature Compensation (AMB) Display Mode when high accuracy readings under both of these conditions are required: • The target has a low emissivity.
° F PRN NOTE ° F ATC NOTE Using the Handheld Infrared Thermometer 2 2-18 8. Press and hold the key until the Emissivity Display Mode (E) appears. 9. Change the emissivity to the proper value for the target being measured (refer to Section 2.3.1). 10.
Figure 2-14. Serial Printer Hookup 3. Pull the trigger and press the key to lock the trigger. The icon will appear on the display. 4. Press and hold the until the Print Data display Mode (PRN) appears. 5. Press the key to increment the printing interval.
° F PRN ° F PRN Using the Handheld Infrared Thermometer 2 2-20 7. After all data is taken, press the key again and the. icon disappears. 8. Press and hold the until the Emissivity display Mode (E) appears. 9. Press the key to unlock the trigger. 2.3.
How to Install IR_TEMPSOFT Please follow this installation procedure to install IR_TEMPSOFT: 1. Place the supplied CD disk into your CD-ROM drive. Make certain that you are not running any other applications at this time. Running other applications while trying to install IR_TEMPSOFT may cause installation errors.
Using the Handheld Infrared Thermometer 2 2-22 program please contact technical support at Omega Engineering Inc. Connecting the IR-System to the PC Make certain that your Infrared Thermometer is powered down before you attempt to make any connections to the personal computer.
2-23 Using the Handheld Infrared Thermometer 2 waiting for the thermometer to transmit data through your RS-232 port. 4. Begin transmitting data from the thermometer by pressing and holding the key on the thermometer until the Print Data Display Mode (PRN) appears.
Using the Handheld Infrared Thermometer 2 2-24 2.3.11 Storing the Temperature Data on Command (OS534, OS523, OS524) The thermometer can store up to 100 temperature data points on command. Each set of temperature data is broken down into the temperature value, emissivity, and high alarm setpoint for that temperature.
2-25 Using the Handheld Infrared Thermometer 2 2.3.12 Erasing the Temperature Data from Memory The user can erase all 100 temperature data points in memory at any time by using the following procedure: 1. Pull the trigger and press the key. The icon will appear.
2.4 Recall Mode (Passive Operation) Definition: Recall Mode is the passive operational mode of the thermometer . In this mode, you may r eview the most recently stor ed temperature data and parameters. Figure 2-16. General Operational Block Diagram In order to get into the Recall Mode of operation, press the key only.
Table 2-2. Functional Flow Chart (Recall Mode) DISPLAY MODE: Press to... Go to Go to Go to Go to Go to Go to or Go to Go to or Go to Go to Press to... Print stored data Display stored temperature Press or to.
2.4.1 Reviewing the Last Parameters The thermometer stores the last temperature measured in the real time mode (refer to Table 2-1). This temperature can be recalled by pressing the key. - Press the key to review the most recently stored temperature data and parameters.
° F PRN 2-29 Using the Handheld Infrared Thermometer 2 3. To download stored temperature data points from the thermometer, first make certain that it is not in printing mode. Make sure that the IR_TEMPSOFT is installed properly as explained in section 2.
2.6.3 Reviewing Previously Stored Temperature Data (OS534, OS523, OS524) You can review all 100 stored temperature values on the thermometer display using the following procedure: 1. Press and hold the key until you see the Memory Display Mode (MEM) appear.
3-1 Laser Sighting 3 3.1 W arnings and Cautions You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.
Laser Sighting 3 3-2 3.2 Description The Laser Sighting is built into the thermometer. It provides a visual indication of the field of view of the thermometer. Aiming at distant targets (up to 40 feet) becomes much easier by using the Laser Sighting. It is offered in two different models, laser dot, and laser dot/circle switchable.
3-3 Laser Sighting 3 3.3 Operating the Laser Sighting 1. Set the laser power switch to the ON position as shown in Figure 3-2. 2. Aim at the target and pull the trigger. 3. The laser beam and the red power indicator LED will turn on. Refer to Figure 3-1 and Figure 3-2.
The Laser Sighting turns on only when used with the thermometer. The module does not turn on by itself. The line of sight of the thermometer does not coincide with that of the Laser Sighting, as shown in Figure 3-4. The two lines of sight become less critical when measuring distant targets.
4-1 4.1 Sighting Scope The Sighting scope is an accessory for the thermometer. It provides a visual indication of the target being measured. Aiming at distant targets (up to 200 feet) becomes much easier by using the Sighting scope. 4.2 Installing and Operating the Sighting Scope 1.
Sighting Scope 4 4-2 Pair of Mounting Clamps Line of sight of the sighting scope Line of sight of the thermometer 1 1 1/16 (42.8 mm) Figure 4-1. Installing the Sighting Scope.
5-1 Maintenance 5 5.1 Replacing the Batteries When you change the batteries, all of the set parameters (i.e. emissivity, high alarm, low alarm, Target Ambient Temperature) will be reset to the default values. For your convenience, you may want to write down all of the set parameters BEFORE replacing the batteries.
5 Maintenance 5.2 Cleaning the Lens Although all lenses are quite durable, take care to prevent scratching when cleaning them. To clean the lens: 1. Blow off loose particles, using clean air. 2. Gently brush off remaining particles, using a camel hair brush.
T roubleshooting Guide 6 THERMOMETER Problem Solution The thermometer does 1a. Properly install fresh batteries. not turn on (No Display) 1b. If operating under ac power, check that the ac adapter is plugged in properly to the ac wall outlet and to the thermometer.
Troubleshooting Guide 6 6-2 Problem Solution The thermometer is Remove and reinstall the batteries or “locked up” (the disconnect and reconnect the ac display is “frozen”). adapter. The display is either 1. Clean the thermometer lens. erratic or stays at one Refer to Section 4.
6-3 Troubleshooting Guide 6 Problem Solution If you see an error code, either “ERR1”, “ERR2”, or “ERR3”, record the code and call our Customer Service Department. Provide Customer Service with the error code that is displayed in the upper left corner of the display.
Troubleshooting Guide 6 1. The line of sight and the center of the target are offset by design. (refer to Figure 3-4 and the explanation above it for how to compensate for this). Problem Solution The trigger is pulled two times in rapid sequence. Wait at least 2 seconds between two successive trigger pulls.
Specifications 7 (Specifications are for all models except where noted) THERMOMETER Measuring: OS530HR, -22°F to 250°F (-30°C to 121°C) Temperature OS531: 0°F to 750°F (–18°C to 400°C) Range.
Specifications 7 7-2 Average Temperature Accuracy Time Period (under continuous operation): 11 1 ⁄ 2 days Emissivity: 0.10 to 1.00 in 0.01 increments, set via keypad Calculated Temperature Maximum (.
7-3 Specifications 7 Analog Output Accuracy: ±2mV reference to temperature display Power: 4 A A size 1.5 volt batteries (lithium or alkaline) Battery Types Alkaline: general brand Lithium: Eveready E.
Specifications 7 7-4 LASER SIGHTING Wavelength (Color): 630-670 nanometers (red) Operating Distance: Laser Dot 2 to 40 ft. Laser Circle 2 to 15 ft. Max. Output Optical Power: <1mW at 75°F ambient temperature, Class II Laser Product European Classification: Class 2, EN60825-1 Maximum Operating Current: 25mA at 5.
Glossary of Key Strokes 8 8-1 Key(s) Key(s) Functions • Selects one of the following Display Modes: E , MAX, MIN, dIF, AVG, TC, HAL, LAL, AMB, PRN or MEM. • Locks/unlocks the trigger. • Enables/disables High Alarm. • Enables/disables Target Ambient Temperature Compensation.
Glossary of Key Strokes 8 8-2 Notes.
A-1 Appendix: How Infrared Thermometry Works A Thermal Radiation Heat is transferred from all objects via radiation in the form of electromagnetic waves or by conduction or convection. All objects having a temperature greater than absolute zero (-459°F, -273°C, 0 K) radiate energy.
Appendix: How Infrared Thermometry Works A A-2 Blackbody When thermal radiation falls on an object, part of the energy is transmitted through the object, part is reflected and part is absorbed. A blackbody is defined as an ideal object that absorbs all the radiation incident upon it.
A-3 Appendix: How Infrared Thermometry Works A Wien’s Displacement Law describes the exact mathematical relationship between the temperature of a blackbody and the wavelength of the maximum intensity radiation.
Appendix: How Infrared Thermometry Works A A-4 Optics Field of View Accurate measurement of temperature via infrared means depends strongly on the size of the object and the distance between the thermometer and the object.
B-1 Appendix: Emissivity V alues B Table B-1 provides guidelines for estimating the emissivity of various common materials. Actual emissivity, especially of metals, can vary greatly depending upon surface finish, oxidation, or the presence of contaminants.
Appendix: Emissivity Values B B-2 NONMET ALS Material Emissivity ( ε ) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.96 Asphalt, tar, pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-1 Appendix: Determining an Unknown Emissivity C In Appendix A, we showed how emissivity is an important parameter in calculating the temperature of an object via infrared means. In this section we discuss how to determine a specific emissivity value.
Appendix: Determining an Unknown Emissivity C C-2 Method 3 1. Use this method to measure objects at temperatures below 500°F (260°C). 2. Place a large piece of masking tape on the object (or at least a sample of the object material). Allow time for the masking tape to reach the object temperature.
C-3 Appendix - Determining an Unknown Emissivity C Method 4 1. Paint a sample of the object material with flat black lacquer paint. 2. Set the emissivity to 0.97 and measure and record the temperature of the painted portion of the sample material - Area ‘A’ in Figure C-1.
Appendix: Determining an Unknown Emissivity C C-4 Notes.
I-1 Index I A ac Adapter Input Jack ............. 1-6 Active Operation ...................... 2-8 Aiming Sight “V Groove” ....... 1-4 Alarms ........................... 2-14, 2-15 Alkaline Batteries ...... 2-1, 4-1, 6-3 Ambient Target Temperature Compensation .
Index I I-2 F Field of View: Diagrams ....................... 2-3, 2-4 Positions ................................ 2-2 Fixed Point Monitoring over Time Measurement ................ 2-7 G Gray Bodies (Objects) ............. A-2 H High Alarm Value, setting .
I-3 Index I M Main Display ............................ 1-4 Modes: Real Time .............................. 2-8 Recall ........................ 2-23, 2-25 Moving Surface Scan ............... 2-7 O Optics ........................................ A-4 P Parameters, reviewing .
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase on the base unit and 13 months from date of purchase on Laser Sight Module .
M2891/0903 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connect.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omega Engineering OS530L c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omega Engineering OS530L - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omega Engineering OS530L, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omega Engineering OS530L va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omega Engineering OS530L, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omega Engineering OS530L.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omega Engineering OS530L. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omega Engineering OS530L ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.