M165912I.3 Owner’s Manual Instructions for I nstallation/Set- up, Operation, Servicing, & S torage Portable, Out door Use-Only, Gas oline G enerator 2,400 Watt C ontinuous (2,7 00 Watt Sur ge) C.
Hazard Signal Word Definitions 2.
Table of Contents 3 Hazard Signal Word Definitions ................................................................................................. 2 About Your Generator ...............................................................................
About Your Generator 4 Thank you for p urchasin g your NorthS tar portable generator! About Your Gene rator This engine-driven, portable generator is designed to provide up to 2700 Watts of electrical power (2400 watts continuous, 2700 watts surge). I t can suppl y power: 1.
About Your Generator (cont’d) 5 Proper preparation, operation, and maintenance will result in operator safety , as well as best performance and long life of the ge nerator. For detailed engine operation and maintenance information, always refer to the engine Owner’s Manual furnished with the generator.
Specifications 6 SPECIFICATIONS Item Number #165912 Maximum Output 2700 Watts ( W ) Continuous Output 2400 Watts ( W ) Generator Type Brushless Voltage 120 Volt (V) Phase Single phase Frequency 56.5 - 63.3 Hertz (Hz) Power Factor 1.0 p.f. Engine 5 Hp Honda GC160 AVXA Engine Speed 3390 - 3798 RPM Fuel Type Unleaded gasoline Fuel Capacity 2.
Safety Label Locations 7 PN 39260 BURN HAZARD Do not touch hot muffler. ©2005 NT+E 1-800-270-0810 WARNING Fig02663 Always make sure saf ety labels are in place and in good co ndition . If a safet y label is missing or not legibl e, order new labels o r unsaf e operation could r esult.
Machine Component Id en tification – 165912I.3 8 Figure 1 (Ref . 1-7) Ref. Description Ref. Description 1 Circuit Breaker 7 Choke Lever 2 120V 20A Duplex Rece ptacle 8 Ignition Switch Lever 3 Generator Head 9 Recoil 4 Oil Drain Plug 10 Gas Tank 5 Vibration Isolation Mo unt 11 Air Cleaner 6 Muffler Figure 2 (Ref .
Machine Component Identification – 165912I.3 (cont’d) 9 REFERENCE GUIDE Reference 1 – Circuit Breaker This portable single phase generator has 1, 20 amp (A) push to reset circuit breaker to protect against electrical overloads.
Power Load Planning & Management 10 WARNING NEVER exceed the rated wattage capacity of y our generator. OVERLOADING may cause SERIOUS DAMAGE to the g enerator and attached electrical devices, and may re sult in fire.
Power Load Planning & Management (cont’d) 11 Device Running Watts Device Running Watts Electric range (1 element) 1500 Refrigerator 600 (b) Electric skillet 1250 Slow cooker 200 Furnace fan (1/3.
Installation / Initial Set- Up 12 There are a number of important steps required to set up y our generator for initial u se. These steps are: Steps for Installation / Initial Set- Up 1. Unpacking & delivery inspection. 2. Planning the power load to stay within the generator’s r ated capacity.
Installation / Initial Set- Up (cont’d) 13 3. Set-up either as a BUILDING BA CK- UP or PORTABLE Po wer Source This generator is designed to provide up to 2700W of electrical power. It can supply electricity in two ways: 1. As a back-up, standby power source for a building.
Installation / Initial Set- Up (cont’d) 14 In addition to isolating your gene rator from the utilit y system, the transfer switch connects your generator to a limited set of circuits in your building that have been chosen as critical to operate during a power outage.
Installation / Initial Set- Up (cont’d) 15 Extension cords may be used to power de vices that are located at a distance from the generator. However, use only UL-listed, outdoor-rated, grounded extension cords of the proper size.
Installation / Initial Set- Up (cont’d) 16 4. Select a Suitable Sit e Before using the generator, y ou must select a suitable OUTDOOR location for installation and operation.
Installation / Initial Set- Up (cont’d) 17 Adequate cooling ventilation The generator needs adequate, unobstructed flow of air to allow for proper cooling of engine and generator head. WARNING : Heat build- up from inadequate v entilation can result in fire, po sing a serious risk to nea rby perso ns and structures.
Installation / Initial Set- Up (cont’d) 18 5. Grounding the gen erator Always ensure the generator is properly grounded to prevent electr ical shock.
Operation 19 Once you have set up your generator for use, it is time to start your g enerator. The following are the procedures necessary for safe, succe ssful operation of your generator. Operation Procedures 1. General Safety Rules for Operation 2. Preparing for Operation 3.
Operation (cont’d) 20 Malfunction du ring operation. I mm ediately turn off the gene rator if any of the following conditions arise during operation: o Excessive chang e in engine speed, slow or.
Operation (cont’d) 21 Static electricity and filling the gasoline tank: Static electric ity can initiate from unground ed gasoline tanks or containers, from flo wi ng gasoline, and from persons carr.
Operation (cont’d) 22 2. Preparing for Oper ation Position generator Position generator in accordance with the instructions given in “Installation & Initia l Set - up, Step 4: Select a Suita ble Site” of this manual.
Operation (cont’d) 23 WARN ING : Gasoline fire/ explosion haz ard Gasoline is hig hly flamm able and explosiv e. Heat, sparks, and flames can ignite gaso line vapors, which can becom e widespr ead during fu eling. A flash fire and /or explosio n could result and ca use serious in jury or death.
Operation (cont’d) 24 Keep nozzle in contact with portable conta iner while fil ling. Manua lly control the flow of g asoline ; do NOT use th e nozzle’s l ock -open device. A portable conta iner made of m etal or conduc tive plast ic is preferred because it dissipa tes charge to ground m ore readily.
Operation (cont’d) 25 3. Starting the Engine After you have completed the pre-start checklist procedures, you are ready to start the engine. To start the engine: 1) Disconnect all loads to the generator. 2) Adjust choke: a) To start a cold engine, pull the choke rod to the CLOSED position.
Operation (cont’d) 26 4. Checking Generato r Output Although the speed of the engine was carefully adjusted at the fac tory so that the generator produces the proper voltage and frequency, output voltage should be checked periodically to ensure the generator is working properly before connecting loads to the gener ator .
Operation (cont’d) 27 5. Connecting Loads You will want to be careful when connecting loads so as not to overload the g enerator, especially if you are powering devices with motors that require a higher starting power load.
Operation (cont’d) 28 7. Storage & Exercis e When you are finished using the generator, you must: o Disconnect all loads o Store the generator properly o Plan on exercising the engine regular ly unless the generator is prepared for long-term storage.
Operation (cont’d) 29 Prepare engine for long term storage if needed If you will not be able to exercise t he generator regularly, you must prepare the engine for long term storage to pre vent gum deposits from forming and causing malfunction of the engine.
Maintenance & Repair 30 Inspect and maintain your generator as specified below in order to keep it in saf e and optimal working order. Follow all safety rules and recommended maintenance steps.
Maintenance & Repair (cont’d) 31 Check GFCI (if equipped) Once a month, test the Ground F ault Circuit Interrupter (GFCI) to protect against electrical shock due to failure of the GFCI. (Onl y f or those models equipped with GFCI – See the “Specifications” section.
Troubleshooting 32 TROUBLESHOOTING Problem Possible Cau ses Possible Remed ies Engine will not start. a) Low oil level. b) Fouled spark plug. c) Out of fuel. d) Ignition switch lever in OFF position. a) F ill crankcase to proper oil level. b) Clea n or replace spark plug.
Summary of Important Safety Information for Operation 33 This section provides a summary of the various safety procedures and measures that have been presented throughout the manual. Keep this summary ha ndy and refer to it to refresh your memory about how to safely use y our generator.
Summary of Important Safety Information for Operation (cont’d) 34 licensed electrician i nstalls the generator with a connection t o your building’s electrical cir cuit for use as a standby power syste m, grounding will be co mplete through the buildi ng’s grounding system.
Summary of Important Safety Information for Operation (cont’d) 35 Safety – Durin g Use Safety equipment / contro ls . Always op erate the generator with all safety covers, guards, and barr iers in place and in good working order, and all co ntrols proper ly adjusted for safe operation.
Summary of Important Safety Information for Operation (cont’d) 36 Safety – After use Cool engine before storing. Let e ngine cool for at least f ive minutes before storin g.
Generator Exploded View 165912 - Rev I.3 37.
Generator Exploded View 165912 – Rev I.3 38 Diag # Part # Description Qty 1 305491 Honda 5 hp Engine 1 2 780422 Engine Adapter Plate 1 4 780423 Fan & bolts 1 5 31193 Drive End Bracket 1 7 780424.
Wiring Diagram 165912 - Rev I.3 39 Diag # Part # Description Qty 1 305555 Connector Wire Harness 1 2 306496 W ire Assembly ( W 43, G41, G42) 1 B46 306571 Black Terminated W ire 1 B52 305556 Black Term.
40 This page ha s intentionally been left b lank..
Limited Warranty 41 Dear Valued Customer: The NorthStar Product you j ust purchased is built with the finest material and crafts manship. Use this p roduct properly an d enjoy the benefits fro m its high p erformance. By p urchasing a NorthStar product, y o u show a desire f or quality and durability.
42 Assembled by Northern Tool & Equipment Company, Inc. Burnsville, MN 55306 NorthernTool.com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté North Star M165912I.3 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du North Star M165912I.3 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation North Star M165912I.3, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le North Star M165912I.3 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le North Star M165912I.3, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du North Star M165912I.3.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le North Star M165912I.3. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei North Star M165912I.3 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.