MODEL 34 MA Y BE INST ALLED IN A SOLID FUEL BURNING FI REPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND. WA R N I N G : If the information in this manual is not followed exactly , a fire or explosion may result causing property dama ge, personal injury or loss of life.
.
T ABLE OF CONTENTS MODEL 34 SECTION I: Safety Information ........................................................................................ 3 SECTION II: Fireplace Preparation/ Solid Fuel Burning Fireplace (FP) ........................... 6 Fireplace Clearances(FP) .
.
SECTION I SAFETY INFORMA TION W ARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERAT E, OR SERVICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEAT H FROM BURNS, FIRE, EXPLOSION, AND CARBON MON OXIDE POISONING.
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas suppl y. - Do not try to light any appliance. - Do not touch any electrical switch; do n ot use any phone in your building.
21. All heater screens must be kept closed when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening (s) of the burner (s) clean may result in sooting and property damage.” 23. Do not use this heater for burning trash or cooki ng.
SECTION II FIREPLACE PREP ARA TI ON The fireplace needs to be prepared before installing the heater. A. Turn off the gas supply to the fireplace. W ARNING: BEFORE INSTALLING IN A SOLID-FUEL B URNING FIREPLACE, THE CHIMNEY FL UE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, AS HES, AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER.
INST ALLA TION AND CLEARANCES To ensure a safe installation into a masonry or fact ory built fireplace, the following instructions must be carefully followed: (1) Sidewall Clearances: Clearance from the side of the fireplace opening to any adjacent co m bustible wall should not be less than: right side 7", left side 7".
CR3329 CERAMIC LOG SET PLACEMENT , FOR MODEL 34 (1-L) (2) (4) (3) WARNING: Failure to position the parts in accordance w ith these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
EMBER STOVE LOG SET PLACEM ENT FOR M ODEL 34 MODEL E.S.B: 1)Rear Log, 2)Middle Log, 3) Left Top Middle Log, 4)Right Top Middle Log 5)Left Front Log 6)Right Front Log 7)Glowing Embers in front of 5 & 6 logs. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (See Figure 2).
GAS PRESSURE CHECK Check the inlet pressure to the burner to ensu re that it is as shown in the ta ble below. NOTE: The pressure check point is located on the righ t side of the valve facing burner, for ITT, and the left side for SIT.
LIGHTING INSTRUCTIONS MILLIV O L T V AL VE (ITT) FOR YOUR SAFETY , READ BEFORE LIGHTING W ARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP ERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be li ghted by hand.
LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully close d.If equipped with the rmostat set to the lowest setting. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your servi ce technician or gas supplier. T O TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1. Open access panel door located at bottom front of the ap pliance.
THERMOST A T CONTROL OPERA TION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat or Remo te control.
LIGHTING INSTRUCTION MODULA TING V AL VE (SIT) MANUAL V AL VE (SIT) FOR YOUR SAFETY RE AD BEFORE LIGHTING W ARNING IF YOU DO NOT FOLLOW THESE INST RUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPER TY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 15. 2. Make sure manual shutoff valve is fully closed. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5.
11. Turn gas control knob counterclock wise to “ON” position. Continue to turn the gas control knob counterclockwise to your desired setting. 12. Close access panel door. 13. Turn on all electrical power to the appliance. CAUTION DO NOT TRY TO ADJUST HEATING LEV ELS BY USING THE MANUAL SHUTOFF VALVE.
THERMOST A T CONTROL OPERA TION 1. The thermostat control on this heater diffe rs from standard thermostats. Standard thermostats simply turn the burner on and of f. The thermostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner.
OPERA TING INSTRUCTIONS Before operating this appliance, proceed throug h the following checklist. 1. Read and understand these instructi ons before operating this appliance. 2. Check that there are no gas leaks. If you sm ell gas do not attempt to light this appliance.
REMOTE CONTROL OR WALL THERMOSTAT NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force. 6. Wait (5) five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in form ation on the reverse side of this label.
* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn control knob counterclockwise to “ON”. 12. If using unit without wall thermostat place Auto/Off/Ma nual switch into the manual position.
MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piez o, it can be manually lit with the us e of a paper match and a lighter rod. 2. Open access panel door located at bottom front of the appliance. 3. Place the match in the holder and light.
FLAME CHECK A periodic check of the flames shou ld be made. The pilot flame should always be present when the gas logs are in operation. See Figure 4. Rear Flames: The flames at the rear or at either .
WIRING DIAGRAM NOTE : “If any of the original wire as s upplied with the gas appliance must be replaced, it must be replaced with a wire of at least a 105 o C. temperature rating.” NOTE : Installation and repair should be done by a qualified service person.
W ARNING: ELECTRICAL GROUNDING INSTRUCTION: THIS HEATER IS EQUIPPED WITH A THREE-PRONG PLUG FOR YOUR PROTEC TION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERL Y GROUNDED THREE-PRONG RECEPTACLE. NOTE: #PESBRO84 Blower may be used with Model FP-42-ZC.
SECTION III INST ALLA TION MODEL 34 (FP) IN SOLID FUEL BURNING FIREPLACES (1) The Model FP-34 may be installe d in a masonry fireplace. The minimum fireplace dimension must be 24" high, 29-1/2" wide, and 12" deep. (2) For minimum dimensions for th e sidewall and m antel, see Figure 6.
B. Set the top (long) trim panel in place on top of unit. The panel should be f lat against the outside face of the fireplace, and standing vertically.
SECTION IV INST ALLA TION OF MODEL 34 (WS) OPTIONAL WOODEN SURR OUND (KIT#P AKDFP34) NOTE: See page 26, figure 6 for clearances. (1) When choosing the right location for your heater and surroun d (man.
STEP 7: Slide the unit into th e front opening of the surround so the top m etal trim panel and outer sides of the heater meet flush with the surround front. STEP 8: Remove cloth or blanket from underneath stove. STEP 9: Take the two metal “ell” brackets with the screws provided and anchor the back of the fireplace to the surround.
SECTION V MODEL 34 (ZC) ZERO CLEARANCE INST ALLA TION The installation must conform with local c odes ,or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54 . This appliance may be installed in an After-Market * Manufactured (Mobile) Home, where not prohibited by state or local codes.
3-1/4" 4-1/4" GAS LINE WARNING: Installation and repairs should be performed by a qualif ied service person. The appliance should be inspected before use and at least annually by a professional ser- vice person. More frequent cleaning may be re quired due to excessive lint from carpeting, bedding material, etc.
FIREPLACE CLEARANCES (ZC) The fireplace may be placed directly on a combustible floor, against a combustible wall at m arked clear- ances, or on a raised wooden platform. If the fireplace is to be installed on a raised wooden platform, the platform must be a continuous level surface.
FINISHING YOUR FIREPLACE (ZC) There is a wide variety of finishing material available for your fireplace from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. Non- combustib le mate rials used in this installation such as slate, tile, m arble, etc.
SECTION VI AFTER MARKET MOBILE HOME INST ALLA TION NOTE : See “Producing Adequate Ventilation” page 35 . THIS APPLIANCE MAY BE INSTALLE D IN AN AFTERMARKET*, PERMANENTLY LOCATED, MANUFACTURE D (MOBILE) HOME, WHERE NOT PROHIBIT ED BY LOCAL CODES. *After Market: Completion of sale, not for the purpose of resale from the manufacturer.
PRODUCING ADEQUA TE VENTILA TION This section is for residential o r manufactured (mobile) installa tion “This heater shall not be insta lled in a confined space or unusua lly tight construction u nless pro- visions are adequate combus tion and ventilation air.
1. Determine the volume of the space (length x width x height). Length x Width x Hei ght =_________cu.ft.(volume of space) EXAMPLE: 20 ft.(Length) x 16 ft.
VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUI LDING This fresh air would come from an adjoining unconf ined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces.
VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must pr ovide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors.
IMPOR T ANT S AFEGUARDS Although your gas logs are very realistic in appearan ce, it is not a real burning fireplace and must not be used for burning rejected material.
TROUBLESHOOTING W ARNING TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVI CING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAI R HEATER. CAUTION NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/ PILOT.
OBSERVED PROBLEM ODS/PILOT lights but flame goes out when control knob is released 4. Air in gas lines when installed 5. Depleted gas supply 6. ODS/Pilot is clogged 7. Gas regulator setting is not correct POSSIBLE PROBLEM 1. Control knob is not fully pressed in 2.
OBSERVED PROBLEM Burner does not light after ODS/ Pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit POSSIBLE CAUSE 1. Burner orifice is clogged 2.
W ARNING IF YOU SMELL GAS: * SHUT OFF GAS SUPPLY * DO NOT TRY TO LI GHT APPLIANCE * DO NOT TOUCH ANY E LECTR ICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDI NG * IMMEDIATELY CALL YOUR GA S SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS SUPPLI ER’S INSTRUCTIONS.
SER VICING Repair and replacement work should only be perf ormed by a qualified service technician. Always shut off the gas supply and make sure heater is cool before beginning any service operation. Check for gas leaks after servicing. REP AIR P AR TS A parts list with exploded view follows.
REPLACEMENT P AR TS ITT VALVE (Picture on page 46) KEY# PART DESCRIPTION PART NUMBER 1. Carling Switch PE RA911VB 2. Female Terminals PE 5X425 3. Piezo Igniter PE 124461 4. Piezo 14" Igniter Wire PE UL3573 5. Pilot (NAT.) Copreci PE 2150053 - NAT.
ON 1 2 3 4 6 7 8 9 20 13 17 16 19 12 5 11 14 15 18 10 21 THERMO GEN AUX P R E S S T O R E S E T OFF P IL O T O N ITT GENERAL CONTROLS PILOT ADJ 46.
REPLACEMENT P AR TS SIT MODULATING OR MANUAL VALVE (Picture on page 48) KEY# PART DESCRIPTION PART NUMBER 1. Pilot (NAT.) Copreci PE 2150053 - NAT. 1. Pilot (LP) Copreci PE 2150054 - LP 2. Thermocouple (Copreci) PE TPT100 / 90 3a. Pilot Tube 1/4" MF 147AL 3b.
10 PILOT O F F H I L O Sit 9 1 2 3A 16 18 3B 4 7 5 8 6 12 13 11 12 17 15 14 19 48.
REPLACEMENT P AR TS SIT MILLIVOLT VALVE Picture on Page 50 KEY# PART DESCRIPTION PART NUMBER 1. 820 MV. S.I.T. VALVE LP-PE 820636 NAT– PE 820637 2. GENERATOR (PILOT ASSEMBLY) 3. BURNER TUBE PO DTBURN 4. O.D.S PILOT (L.P.) O.P. ASSEMBLY PE 8404C O.D.
SIT MILLIV OL T 15 8 16 2 4 5 3 7 1 6 17 18 19 9 10 11 13 12 14 20 21 50.
REPLACEMENT P AR TS FOR EMBER ST OVE BASE (ESB) (PICTURE ON PAGE 47) A parts list with exploded view follows. Always include correct name, part number, and model number of the heater when ordering service parts. KEY# PART DESCRIPTION PART NUMBER SIT - MILLIVOLT 1.
52 10 6 11 13 8 7 16 16 5 1 14 2 3 4 6 17 15 12 REP AIR P AR TS A parts list with exploded view fo llows. Always include correct name, part number, and model num ber of the heater when ordering service parts. Please contact your local dealer or distributor when ordering .
NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté New Buck Corporation 34 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du New Buck Corporation 34 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation New Buck Corporation 34, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le New Buck Corporation 34 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le New Buck Corporation 34, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du New Buck Corporation 34.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le New Buck Corporation 34. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei New Buck Corporation 34 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.