Manuel d'utilisation / d'entretien du produit MID-7654 du fabricant National Instruments
Aller à la page of 36
National Instruments™, NI™, and ni.com™ are t rademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or tra de names of their respectiv e companies. 322691B-01 Copyright © 2000, 2001 National Instr uments Corp.
MID-7654/7652 Servo Power Motor Drive User Gu ide 2 ni.com Modifying the Power Entry Module .................. ........... .............. ........... ..30 Replacing a Fuse.......... ........... .............. ........... .............. ............ ..
© National Instruments Corporatio n 3 MID-7654/7652 Servo Power Motor Drive User Guide The MID-7654/7652 simplif ies your field wiring through separate encoder , limit switch, and motor power remov able scre w terminal connector blocks for each axis.
MID-7654/7652 Servo Power Motor Drive User Gu ide 4 ni.com qualified to do so and disconnect all field po wer prior to removing cov ers or shields. • Do not operate damaged equip ment. The safety protection features built into this device can become impaired if the device becomes damaged in any way .
© National Instruments Corporatio n 5 MID-7654/7652 Servo Power Motor Drive User Guide Front Panel Switches Figure 1 shows the front panel for y our MID-7654/7652.
MID-7654/7652 Servo Power Motor Drive User Gu ide 6 ni.com The EN ABLE switch en ables or inhibits the servo amplifiers. If the EN ABLE switch is in the inhibit position (O FF), the amplifier output stages are inhibited and the yello w LED s for all ax es illuminate.
© National Instruments Corporatio n 7 MID-7654/7652 Servo Power Motor Drive User Guide Amplifier Fault Output LEDs The top row of the LED status array indicates the status of the amplifiers. A red LED indicates an overcurrent condition, a short circuit condition, an over temperature condi tion, or a problem with the motor bus voltage on that axis.
MID-7654/7652 Servo Power Motor Drive User Gu ide 8 ni.com Front Panel DIP Switch Settings The MID-7654/7652 front panel has a detachable me tal plate that, when removed, provides access to one 4-position DIP switch bank and either four (MID-7654) or two (MID-7652) 9-position DIP switch bank s.
© National Instruments Corporatio n 9 MID-7654/7652 Servo Power Motor Drive User Guide Inhibit Input Polarity Setting U s eD I Ps w i t c h1o nt h e4 - p o s i t i o nD I Ps w i t c hb a n kt og l o b a l l ys e tt h e polarity for the inhibit inpu t for all axes.
MID-7654/7652 Servo Power Motor Drive User Guid e 10 ni.com Limit Status LED Polarity Setting U s eD I Ps w i t c h3o nt h e4 - p o s i t i o nD I Ps w i t c hb a n kt og l o b a l l ys e tt h e polarity for the Limit Status LED. Refer to Figures 1 and 3 for the location of this switch .
© National Instruments Corporatio n 11 MID-7654/7652 Servo Power Motor Drive User Guide Figure 4 illustrates the com mand voltage input to current output relationship for periods of tim e less than 2.7 seconds. Figure 4. Input V oltage to Output Current Relationship for Periods of Time Less Than 2.
MID-7654/7652 Servo Power Motor Drive User Guid e 12 ni.com The amplif ier peak and continuous current limits ha ve been factory set for 5 A continuous current output and 10 A peak current ou tput. V erify that these settings are appropriate for your applicatio n before powering your motors.
© National Instruments Corporatio n 13 MID-7654/7652 Servo Power Motor Drive User Guide If you are connecting multiple m otors to your MID-7654/7652, verify that the total power dissipated by the motors at an y given time is less than the total po wer the dri ve can provide.
MID-7654/7652 Servo Power Motor Drive User Guid e 14 ni.com Use the last DIP switch on each of the 9-position DIP switch bank s to set the motor inductance lev el for each axis. Refer to Figures 1 and 3 for the location of the of the motor inductance lev el switch.
© National Instruments Corporatio n 15 MID-7654/7652 Servo Power Motor Drive User Guide Back Panel Connector Wiring Figure 6 shows the MID -7654/7652 back panel connectors wi thout their rear guards.
MID-7654/7652 Servo Power Motor Drive User Guid e 16 ni.com Caution Be sure to turn of f the EN ABLE and A C POWER switches for your MID-7654/7652 and host com puter and disconnect the unit from the power outlet before making connections to your mo tion controller .
© National Instruments Corporatio n 17 MID-7654/7652 Servo Power Motor Drive User Guide T erminal Block Wiring This section describes how to wire the terminal blocks on your MID-7654/7652. Ser vo Motor Power T erminal Blocks For motor power wiring, each MID-7654/7652 axis has a separate 5-position removable screw terminal block.
MID-7654/7652 Servo Power Motor Drive User Guid e 18 ni.com Depending on your motor, you may need to rev erse the connectio ns shown in Figure 7, as there is no industry standard for di rection of mov ement relativ e to the positive and ne gativ e mo tor inputs.
© National Instruments Corporatio n 19 MID-7654/7652 Servo Power Motor Drive User Guide Rear Guard The rear guard consists of the protecti on cover, protection plates, and bottom mounting plate as shown in Fi gure 9.
MID-7654/7652 Servo Power Motor Drive User Guid e 20 ni.com The rear guard installed on the MID-7654/7 652 is shown i n Figure 10. Figure 10. Rear Guard Installed on the MID-7654/7652 Warning The serv o motor connectors on this driv e are ener gized when the unit is po wered on.
© National Instruments Corporatio n 21 MID-7654/7652 Servo Power Motor Drive User Guide Figure 11. Protection Cover and Protection Plates: Used Axes 1 & 2, Unused Axes 3 & 4. Note The protection plates for any unused axes should remain installed in the closed position at all times, as shown on axes 3 and 4 in Figure 11.
MID-7654/7652 Servo Power Motor Drive User Guid e 22 ni.com 7. Ensure that the rear guard is held securely in place before reconnecting your MID-76 54/7652 to a p o wer outlet. Encoder T erminal Blocks For quadrature incremental encoder signals, each MID-7654/7652 axis has a separate 8-position removable screw terminal block.
© National Instruments Corporatio n 23 MID-7654/7652 Servo Power Motor Drive User Guide Note If you require other encoder power v oltages, reference an external po wer supply to the Digital Ground sign al on the 8-pin encoder terminal bl ock. The MID-7654/7652 supports di f f erential inputs for Phase A, Phase B, and Index signals.
MID-7654/7652 Servo Power Motor Drive User Guid e 24 ni.com Figure 15. Shielded T wisted Pairs Note Using an unshielded cabl e may produce noise, wh ich can corrupt the encoder signals and cause lost counts, reduced accuracy , or other erroneous encoder and controller operation.
© National Instruments Corporatio n 25 MID-7654/7652 Servo Power Motor Drive User Guide Breakpoint and T rigger T erminal Blocks Both the breakpoint an d trigger connectors use a 6-p in removable terminal block. The trigger terminal block provides access to the trigger input lines, shutdo w n input line, and digital ground.
MID-7654/7652 Servo Power Motor Drive User Guid e 26 ni.com Figure 19. Analog Input T erminal Block Pin Assignment Figure 20. Analog Output T erminal Block Pin Assignment Step and Direction T erminal .
© National Instruments Corporatio n 27 MID-7654/7652 Servo Power Motor Drive User Guide Cable Installation for CE Compliance Take the following additional steps to ensure CE Compliance: 1. Enclose the terminal block w ires in a 360-degree shielded cable.
MID-7654/7652 Servo Power Motor Drive User Guid e 28 ni.com b . Lay the cables so that the braided shield makes full contact with the foam of the strain-relief bar . The braided shield must only make contact with the strain-relief bar , and no other part of the de vice.
© National Instruments Corporatio n 29 MID-7654/7652 Servo Power Motor Drive User Guide Figure 23. MID-7654/7652 with the Strain-Relief Bar Installed Panel Mount Kit Installation The panel mount kit allows you to m ount the MID-7654/7652 insid e a cabinet or enclosure.
MID-7654/7652 Servo Power Motor Drive User Guid e 30 ni.com Figure 24. MID-7654/7652 with the Pan el Mount Kit Installed Note The strain-relief bar and panel mount kit cannot be installed at the same time, because they will not simultaneously f it under the sides of the bottom mounting plate.
© National Instruments Corporatio n 31 MID-7654/7652 Servo Power Motor Drive User Guide 4. Push the fuse holder back into the power entry module with the same orientation you observed in step 2. 5. Close the hinged cover . Changing the Line V oltage Follow these steps to change the line vol tage on your MID-7654/7652: 1.
MID-7654/7652 Servo Power Motor Drive User Guid e 32 ni.com Continuous current limit ................ .........0.85 – 5 A (default 0.85 A) DC-bus motor voltage ................... .........48 VDC PWM frequency ............... .......................
© National Instruments Corporatio n 33 MID-7654/7652 Servo Power Motor Drive User Guide Analog Inputs Noise filter (RC time constant) .............. 10 µ s Compatibility ............... .............. ............ Signal p ass-through Analog Outputs Compatibility .
MID-7654/7652 Servo Power Motor Drive User Guid e 34 ni.com AC power ......................... .......................Detachable AC power cord (IEC standard type) Motion I/O ................. .............. ...............68-pin female high density VHDCI type Environment Operating temperature .
© National Instruments Corporatio n 35 MID-7654/7652 Servo Power Motor Drive User Guide Safety Meets the requirements of the following standards for safety for electrical equipment for measurement, c.
T echnical Support Resources NI We b Support National Instruments W eb support is yo ur first sto p for help in solving installation, configuration, and application problems a nd questions.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté National Instruments MID-7654 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du National Instruments MID-7654 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation National Instruments MID-7654, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le National Instruments MID-7654 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le National Instruments MID-7654, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du National Instruments MID-7654.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le National Instruments MID-7654. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei National Instruments MID-7654 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.