FieldPoint TM cFP-20 xx Quick Start Guide What Y ou Need to Get Set Up • cFP-20 xx LabVIEW RT controller • Mounting hardware (DIN rail, panel- mount, or rack-mount accessory) • I/O module(s) •.
2 cFP-20xx Quick Start Guide ni.com Mounting the Backplane on a DIN Rail A. Fasten the DIN rail clip(s) to the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the clip(s). B. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip.
Mounting the Backplane on a Panel A. Fasten the panel-mount plates to the back of the cFP-BP- x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the kit. B. Bolt or screw the panel-mount accessory to a panel.
Mounting the Backplane in a Standard 19-in. Rack A. Fasten the rack-mount bracket to the back of the cFP-BP- x using the captive screws on the bracket. B. Bolt the rack-mount accessory to a standard 19-in. rack. C. Connect the PE ground terminal on the cFP-BP- x to safety ground.
I I n n s s t t a a l l l l t t h h e e c c F F P P - - 2 2 0 0 x x x x C C o o n n t t r r o o l l l l e e r r o o n n t t h h e e B B a a c c k k p p l l a a n n e e A.
6 cFP-20xx Quick Start Guide ni.com I I n n s s t t a a l l l l I I / / O O M M o o d d u u l l e e s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e A. Align the captive screws on the I/O module with the holes on the backplane. B. Press firmly to seat the I/O module on the backplane.
I I n n s s t t a a l l l l C C o o n n n n e e c c t t o o r r B B l l o o c c k k s s o o n n t t h h e e B B a a c c k k p p l l a a n n e e In order to connect I/O modules to input signals or to external loads, you need to install a cFP-CB- x connector block or other connectivity accessory for each I/O module on the backplane.
C C o o n n n n e e c c t t t t h h e e c c F F P P - - 2 2 0 0 x x x x t t o o Y Y o o u u r r N N e e t t w w o o r r k k Connect the cFP-20 xx controller to an Ethernet network using the RJ-45 Ethernet port on the controller .
C. Use a separate power supply for each module that needs external power . D. Refer to the operating instructions for the power requirements of each I/O module. If a module requires external power , connect a power supply to the V and C inputs on the connector block for that module.
I I n n s s t t a a l l l l S S o o f f t t w w a a r r e e o o n n t t h h e e H H o o s s t t P P C C A. Install the software packages you plan to use, such as LabVIEW , LabVIEW RT , Lookout, Measurement Studio, or LabWindows/CVI, before you install the FieldPoint software.
11 cFP-20xx Quick Start Guide © National Instruments Corporation C. Click the + + sign next to I I A A S S e e r r v v e e r r w w i i t t h h O O P P C C in the left pane to expand the view .
G. Enter values on the Network Settings tab of the System Configuration dialog box, shown in the figure at right. If your network does not have a gateway server or DNS server , you should set those parameters to 0.0.0.0. • I I P P A A d d d d r r e e s s s s —The unique, computer-readable address of a device on your network.
I. Enter an IP address for the T ime Server on the Servers tab of the System Configuration dialog box, shown in the figure at right. The time server is a networked computer that runs the National Instruments T ime Service installed by FieldPoint Explorer .
14 cFP-20xx Quick Start Guide ni.com F F i i n n d d i i n n g g a a n n d d C C o o n n f f i i g g u u r r i i n n g g D D e e v v i i c c e e s s a a n n d d C C h h a a n n n n e e l l s s After you have configured the cFP-20 xx in FieldPoint Explorer , follow these steps to configure Compact FieldPoint devices and channels.
C. T o configure the hardware settings of a particular I/O module, right-click the device name and select E E d d i i t t t t h h i i s s d d e e v v i i c c e e . The Device Configuration dialog box appears, as shown in the figure above. For output modules, you can choose settings for Watchdog Configuration.
16 cFP-20xx Quick Start Guide ni.com D. Click C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n to access the Channel Configuration dialog box, shown in the figure at right. Make your selections in this dialog box as follows: 1.
17 cFP-20xx Quick Start Guide © National Instruments Corporation.
18 cFP-20xx Quick Start Guide ni.com S S a a v v i i n n g g H H a a r r d d w w a a r r e e C C o o n n f f i i g g u u r r a a t t i i o o n n a a s s P P o o w w e e r r - - U U p p S S t t a a t t.
ni.com Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté National Instruments CFP-20XX c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du National Instruments CFP-20XX - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation National Instruments CFP-20XX, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le National Instruments CFP-20XX va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le National Instruments CFP-20XX, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du National Instruments CFP-20XX.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le National Instruments CFP-20XX. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei National Instruments CFP-20XX ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.