Manuel d'utilisation / d'entretien du produit GVF40N du fabricant Napoleon
Aller à la page of 24
1 W415-0319 / D / 08.03.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@nap oleon.
2 W415-0319 / D / 08.03.05 Hood Louvre Bracket Hinge Screen Louvre Installation & Removal Heat Shield S tand Off Removal Logo Placement 16-17 O PTIONS Patented Catalytic Glass Door Blower Installa.
3 W415-0319 / D / 08.03.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0319 / D / 08.03.05 This fireplace may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not pr ohibited by local codes . This fireplace is only for use with the type of gas indi- cated on the r ating plate .
5 W415-0319 / D / 08.03.05 This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are provided for adequate combustion and ventila tion air .
6 W415-0319 / D / 08.03.05 50 If in this example a solid door separates Room 1 from Room 2, the volume of Room 2 could not be used. In this case the maximum BTU/h would be: Maximum BTU/h: 800 x 1000 =.
7 W415-0319 / D / 08.03.05 FIGURES 4 a-d PENINSULA OPEN-END SEE-THRU 4-SIDED.
8 W415-0319 / D / 08.03.05 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
9 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
10 W415-0319 / D / 08.03.05 FIGURE 14 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
11 W415-0319 / D / 08.03.05 Install the base panels as illustrated in steps 1-4 on page 9. Both side panels sit under the bracket tab . Holding the side panel in position, bend down the tab to secure.
12 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
13 W415-0319 / D / 08.03.05 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
14 W415-0319 / D / 08.03.05 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.
15 W415-0319 / D / 08.03.05 L36 LOUVRE INST ALLA TION FIGURE 32 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
16 W415-0319 / D / 08.03.05 Notes: Ornamental insets can not be used in conjunction with the catalytic door When using a catalytic door , glassed doors must be used on all other side or end openings. This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
17 W415-0319 / D / 08.03.05 Remove the thermodisc bracket from the top of the firebox. Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.
18 W415-0319 / D / 08.03.05 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fireplace.
19 W415-0319 / D / 08.03.05 THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED SERVICE PERSON! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
20 W415-0319 / D / 08.03.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
21 W415-0319 / D / 08.03.05.
22 W415-0319 / D / 08.03.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
23 W415-0319 / D / 08.03.05 White / grey film forms on the glass of the optional cata- lytic door . Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner .
24 W415-0319 / D / 08.03.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon GVF40N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon GVF40N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon GVF40N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon GVF40N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon GVF40N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon GVF40N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon GVF40N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon GVF40N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.