Manuel d'utilisation / d'entretien du produit GDS60N du fabricant Napoleon
Aller à la page of 56
1 W415-0788 / B / 1 1.03.10 INST ALLER: LEA VE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RET AIN THIS MANUAL FOR FUTURE REFERENCE. INST ALLA TION AND OPERA TING INSTRUCTIONS 1.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky , USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www .
2 W415-0788 / B / 1 1.03.10 NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. T ABLE OF CONTENTS 1.0 INST ALLA TION OVERVIEW 3 2.0 INTRODUCTION 4 2.1 DIMENSIONS 5 2.2 GENERAL INSTRUCTIONS 5 2.3 GENERAL INFORMA TION 6 2.
3 W415-0788 / B / 1 1.03.10 1.0 INST ALLA TION O VER VIEW Castings, see “FRONT CAST REMOV AL” section. Door , see “GLASS DOOR INST ALLA TION AND REMOV AL” section. Glass, see “GLASS / DOOR REPLACEMENT” section. On/Off, see “SWITCH AND BRACKET INST ALLA TION” section.
4 W415-0788 / B / 1 1.03.10 2.0 INTR ODUCTION 3.2A ! W ARNING • THIS APPLIANCE IS HOT WHEN OPERA TED AND CAN CAUSE SEVERE BURNS IF CONT ACTED. • ANY CHANGES OR AL TERA TIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions.
5 W415-0788 / B / 1 1.03.10 2.1 DIMENSIONS 31 1 / 4 " 30 1 / 2 " 5 1 / 2 " 19 1 / 2 " 27" 17 7 / 8 " 4" DIA. 7" DIA. 24" 2.2 GENERAL INSTRUCTIONS THIS GAS APPLIANCE SHOULD BE INST ALLED AND SER VICED BY A QUALIFIED INST ALLER to conform with local codes.
6 W415-0788 / B / 1 1.03.10 4.1A The installation must conform with local codes or , in absence of local codes, the National Gas and Propane Installation Code CSA B149.1 in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFP A 54 in the United States.
7 W415-0788 / B / 1 1.03.10 When the appliance is installed at elevations above 4,500ft, and in the absence of speci fi c recommendations from the local authority having jurisdiction, the certi fi ed high altitude input rating shall be reduced at the rate of 4% for each ad- ditional 1,000ft.
8 W415-0788 / B / 1 1.03.10 2.5 SHIPPING BRACKET SHIPPING BRACKET REMOV AL A. Remove the four screws holding the shipping bracket to the bot- tom of the appliance. B. Lift the appliance off the skid and set on a fl at surface. C. Discard the screws, brackets and skid.
9 W415-0788 / B / 1 1.03.10 3.0 VENTING - MODEL GDS60 7.1 THIS APPLIANCE USES A 4” EXHAUST / 7” AIR INT AKE VENT PIPE SYSTEM. Refer to the section applicable to your installation. For safe and proper operation of the appliance follow the venting instruction exactly .
10 W415-0788 / B / 1 1.03.10 3.1 VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp, American Metal Amerivent or Metal-Fab venting components.
11 W415-0788 / B / 1 1.03.10 3.2 TYPICAL VENT INST ALLA TIONS 30 1/2" TOP VENT REAR VENT 16" MINIMUM 40 FEET MAXIMUM 34" MINIMUM 16" MINIMUM 40 FEET MAXIMUM 34" MINIMUM 24&quo.
12 W415-0788 / B / 1 1.03.10 20 FT MAX 12” MINIMUM TO GRADE 24” MINIMUM REGARDLESS OF HORIZONT AL VENT LENGTH MAX. HORIZONT AL RUN 34" MAXIMUM 29" MINIMUM 30 1/2" 59 1/2" MINIMUM PLUS RISE* 24" MAX 24" MINIMUM PLUS RISE* * See "VENTING" section.
13 W415-0788 / B / 1 1.03.10 Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” above grade. The maximum allowable vent length is 10’.
14 W415-0788 / B / 1 1.03.10 3.4 VENT TERMINAL CLEARANCES INST ALLA TIONS CANADA U.S.A. A 12” 12” Clearance above grade, veranda porch, deck or balcony . B 12” Δ 9” Δ Clearance to windows or doors that open. C 12” * 12” * Clearance to permanently closed windows.
15 W415-0788 / B / 1 1.03.10 3.5 VENTING APPLICA TION FLO W CHART 13.1 TOP EXIT Horizontal T ermination V ertical T ermination V ertical rise is equal to or greater than the horizontal run V ertical r.
16 W415-0788 / B / 1 1.03.10 3.6 DEFINITIONS 3.7 ELBOW VENT LENGTH V AL UES 14.1 For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or gre.
17 W415-0788 / B / 1 1.03.10 3.8 T OP EXIT HORIZONT AL TERMINA TION (H T ) > (V T ) Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T .
18 W415-0788 / B / 1 1.03.10 3.9 T OP EXIT HORIZONT AL TERMINA TION 16.1A Simple venting con fi guration (only one 90° elbow) (H T ) < (V T ) For vent con fi gurations requiring more than one 90.
19 W415-0788 / B / 1 1.03.10 3.10 REAR EXIT HORIZONT AL TERMINA TION For vent configurations requiring more than two 90° elbows, the following formulas apply: Formula 1: H T < V T Formula 2: H T + V T < 40 feet Example: V 1 = 9 FT V 2 = 6 FT V T = V 1 + V 2 = 9 + 6 = 15 FT H 1 = 3 FT H 2 = 2 FT H 3 = 1.
20 W415-0788 / B / 1 1.03.10 Simple venting configuration (only two 90° elbows) See graph to determine the required vertical rise V T for the required horizontal run H T .
21 W415-0788 / B / 1 1.03.10 3.11 T OP OR REAR EXIT VERTICAL TERMINA TION Simple venting configurations. See graph to determine the required vertical rise V T for the required horizontal run H T .
22 W415-0788 / B / 1 1.03.10 Simple venting configurations. See graph to determine the required vertical rise V T for the required horizontal run H T .
23 W415-0788 / B / 1 1.03.10 Example: V 1 = 1.5 FT V 2 = 5 FT V T = V 1 + V 2 = 1.5 + 1 + 5 = 6.5 FT H 1 = 1 FT H 2 = 1 FT H 3 = 10.75 FT H R = H 1 + H 2 + H 3 = 1 + 1 + 10.75 = 12.75 FT H O = .03 (four 90° elbows + one 45° elbow - 90°) = .03 (360° + 45° - 90°) = 6.
24 W415-0788 / B / 1 1.03.10 4.2 CHANGING A T OP VENT T O A REAR VENT In order to convert the venting con fi guration from a top exit to a rear exit, remove components as illustrated. When reinstalling in the alternate position: Check gaskets for tears, replace if necessary to ensure a proper seal.
25 W415-0788 / B / 1 1.03.10 5.0 INST ALLA TION ! W ARNING FOR SAFE AND PROPER OPERA TION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTL Y . ALL INNER EXHAUST AND OUTER INT AKE VENT PIPE JOI.
26 W415-0788 / B / 1 1.03.10 5.2 WALL AND CEILING PRO TECTION For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" rise per foot when venting. For safe and proper operation of the appliance, follow the venting instructions exactly .
27 W415-0788 / B / 1 1.03.10 5.2.2 VERTICAL INST ALLA TION This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor . See accessories to order speci fi c kits required.
28 W415-0788 / B / 1 1.03.10 5.2.3 HORIZONT AL AIR TERMINAL INST ALLA TION - MODEL GDS60 A. Stretch the inner fl ex pipe to the required length taking into account the additional length needed for the fi nished wall surface. Slip the vent pipe a minimum of 2” over the inner sleeve of the air terminal and secure with 3 #8 screws.
29 W415-0788 / B / 1 1.03.10 5.2.4 VERTICAL AIR TERMINAL INST ALLA TION - MODEL GDS60 A. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
30 W415-0788 / B / 1 1.03.10 5.3 APPLIANCE VENT CONNECTION - MODEL GDS60 A. Attach the adjustable pipe to the last section of rigid pipe. Secure with screws and seal. B. Install the inner fl ex pipe to the appliance. Secure with 3 screws and fl at washers.
31 W415-0788 / B / 1 1.03.10 5.5 GAS INST ALLA TION For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2 strand solid core millivolt wire from the gas appliance to the wall switch / millivolt thermostat.
32 W415-0788 / B / 1 1.03.10 5.7 B-VENT SPECIFICS - MODEL GS60 5.7.1 CHIMNEY INST ALLA TION 63.7 “A” VENT - SOLID FUEL WOOD BURNING CHIMNEY & VENT CONNECTOR (LINER NEEDED IF INSIDE DIAMETER IS.
33 W415-0788 / B / 1 1.03.10 5.7.2 INST ALLING "B" VENT Follow the instructions of the "B" vent manufacturer for chimney installation. A. Remove the access plate. Remove and discard the air intake cover plate located directly behind the access plate.
34 W415-0788 / B / 1 1.03.10 5.7.5 ADDING VENT SECTIONS A dd chimney sections, according to the manufacturers installation instructions. The chimney must extend at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof, building or obstacle within 10 feet horizontally .
35 W415-0788 / B / 1 1.03.10 5.7.6 INST ALLING FLASHING AND ST ORM COLLAR SECUREL Y A TT ACH VENT ADAPTER TO FLUE COLLAR 4” “B” VENT 7” OPTIONAL VENT PIPE 3 FT MIN 2 FT MIN 10 FT 88.1 Remove the nails from the shingles above and to the sides of the chimney .
36 W415-0788 / B / 1 1.03.10 6.0 FINISHING A. Lift the top casting off. B. Lift the cast front out of its retainers (located at either side on the top). C. Open the valve control cover . Pull the latch handles forward to release. The door may now be safely removed by swinging the bottom out and lifting it off.
37 W415-0788 / B / 1 1.03.10 1 4 2 3 5 Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Phazer tm logs glow when exposed to direct fl ame and provide a unique and realistic glowing effect. Use only certi fi ed phazer tm logs available from your Napoleon® dealer .
38 W415-0788 / B / 1 1.03.10 6 7 Position the notch located in log #6 against the grate post. Place the bottom of log #7 against the right outermost grate post and the top into the pocket provided on the center log (#6). Bend up the tab in the log support to cradle log #7.
39 W415-0788 / B / 1 1.03.10 6.6 SWIT CH AND BRACKET INST ALLA TION 1 3 CONNECT THE TWO WIRES TO THE SWITCH TERMINALS. 2 ACCESS COVER PLA TE.
40 W415-0788 / B / 1 1.03.10 7.0 OPTIONAL BL O WER INST ALLA TION A. Ensure that the access cover plate has been installed. For location, see "SWITCH AND BRACKET INST ALLA TION" section. B. Remove the on/off switch bracket and the cover plate below it.
41 W415-0788 / B / 1 1.03.10 8.0 WIRING DIA GRAM 69.5 ! W ARNING DO NOT WIRE 1 10 VOL TS TO THE V AL VE OR W ALL SWITCH. ON / OFF SWITCH ACS/IPI SWITCH (OPTIONAL) DC BACK-UP GROUND DFC VA LV E ORANGE GREEN GROUND EYELET ON / OFF IPI / CPI DISCONNECT THESE CONNECTORS T O THE ON/OFF SWITCH AND CONNECT T O OPTIONAL THERMOST A T .
42 W415-0788 / B / 1 1.03.10 9.0 OPERA TION MODEL GS60 ONL Y : SPILL SWITCH This is a thermally activated switch, attached to the back of the chimney adaptor , which senses the change in temperature and shuts down the gas valve in the event of a blocked or disconnected vent.
43 W415-0788 / B / 1 1.03.10 9.2 OPERA TING INSTRUCTIONS - FOR Y OUR SAFETY READ BEFORE OPERA TING 9.3 LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONS / INSTRUCTIONS D’ALLUMAGE 1. STOP! READ ALL INFORMA TION OF OPERA TING AND LIGHTING INSTRUCTIONS BEFORE PROCEEDING.
44 W415-0788 / B / 1 1.03.10 10.0 ADJUSTMENT 10.1 PILO T B URNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow .
45 W415-0788 / B / 1 1.03.10 11.0 MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. This appliance and its venting system should be inspected before use and at least annually by a quali fi ed service person.
46 W415-0788 / B / 1 1.03.10 12.0 REPLA CEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor . FOR W ARRANTY REPLACEMENT P ARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
47 W415-0788 / B / 1 1.03.10 GS60 COMPONENTS REF NO. P ART NO. DESCRIPTION 31 W010-0459 ADAPTOR C/W SPILL SWITCH 32 W660-0006 SPILL SWITCH 33 W080-0405 SPILL SWITCH BRACKET TERMINAL KITS REF NO.
48 W415-0788 / B / 1 1.03.10 ACCESSORIES REF NO. GDS60-1 GS60 DESCRIPTION 18* W573-0007 W573-0007 HIGH TEMPERA TURE SEALANT 52* W690-0001 W690-0001 MILLIVOL T THERMOST A T 53* F40 F40 ON/OFF REMOTE 54.
49 W415-0788 / B / 1 1.03.10 45 48 47 46 64 44 24 36 41 37 43 34 25 27 10 1 2 3 4 5 7 6 31 33 32 44 28 26 56 9 20 11 59 67 35 8 40 43 43 50 13 12 51 49.
50 W415-0788 / B / 1 1.03.10 13.0 TR OUBLE SHOO TING SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. Makes noise with no spark at pilot burner . Wiring. - V erify the wire for the sensor and the wire for the ignitor are connected to the correct terminals (not reversed) on the module.
51 W415-0788 / B / 1 1.03.10 SYMPTOM PROBLEM TEST SOLUTION Carbon is being deposited on glass, logs, rocks, media or combustion chamber surfaces. Air shutter has become blocked. - Ensure air shutter opening is free of lint or other obstructions. Flame is impinging on the glass, logs, rocks, media or combustion chamber .
52 W415-0788 / B / 1 1.03.10 42.7_3 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber surfaces. - Clean the glass, see “CARE OF GLASS” section - DO NOT CLEAN GLASS WHEN HOT .
53 W415-0788 / B / 1 1.03.10 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only . Registering your warranty is not necessary . Simply provide your proof of purchase along with the model and serial number to make a warranty claim.
54 W415-0788 / B / 1 1.03.10 15.0 SER VICE HIST OR Y 43.1.
55 W415-0788 / B / 1 1.03.10 16.0 NO TES 44.1.
56 W415-0788 / B / 1 1.03.10 44.1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon GDS60N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon GDS60N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon GDS60N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon GDS60N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon GDS60N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon GDS60N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon GDS60N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon GDS60N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.