Manuel d'utilisation / d'entretien du produit GT8P du fabricant Napoleon Fireplaces
Aller à la page of 22
1 W415-0619 / B / 03.03.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.
2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION W arranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING V enting Lengths and Air T erminal Locations Ve.
3 W415-0619 / B / 03.03.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® e following ma te rials and workmanship in your new NAPO LEON® gas firepla ce are waanted agains t defects for as long as you own the fireplace.
4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is impor.
5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner .
6 W415-0619 / B / 03.03.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning.
7 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - HORIZONT AL TERMINA TION MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) N/A 1 Rise per fo.
8 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - VERTICAL TERMINA TION 24” MIN. MINIMUM VERITICAL 4” MIN. FIGURE 3a 24” MIN. MINIMUM VERITICAL MAXIMUM HORIZONT AL 5 FT MAX.
9 W415-0619 / B / 03.03.08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL L OCA TION CLEARANCES N D E O FIGURE 4.
10 W415-0619 / B / 03.03.08 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high.
11 W415-0619 / B / 03.03.08 1. Stretch the 3” fl exible vent pipe to the required length taking into account the additional length needed for the fi nished wall surface.
12 W415-0619 / B / 03.03.08 HIGH TEMPERA TURE SEALANT 1 1 / 2 ” OVERLAP SCREWS 1. Install the 3” fl exible vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied).
13 W415-0619 / B / 03.03.08 Do NOT use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TEL Y to have the fi replace inspected for damage to the electrical circuit. IT IS NECESSAR Y T O HARD WIRE THIS FIREPLACE.
14 W415-0619 / B / 03.03.08 FRAMING FIGURES 21a,b&c NAILING T AB INST ALLA TION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 The has been designed to be installed mid-way up a wall.
15 W415-0619 / B / 03.03.08 2” MIN.* 12” MIN. TO COMBUSTIBLES (to ceiling or mantle) 1 1 / 2 ” MIN. * Any protruding finishing material installed in this space (ie. baseboards) must leave 2” of unobstructed clearance to allow for full rotation of the control door .
16 W415-0619 / B / 03.03.08 FIGURE 28 RECEIVING SLOTS DOOR STOP CHAIN FRAME/FRONT INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied.
17 W415-0619 / B / 03.03.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the fi replace. 2 . Remove the frame from the unit by removing the 2 black securing screws from the top, and the 2 silver hex head securing screws from the bottom.
18 W415-0619 / B / 03.03.08 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
19 W415-0619 / B / 03.03.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established.
20 W415-0619 / B / 03.03.08 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BUR.
21 W415-0619 / B / 03.03.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to spark for complete 7 seconds, burner shuts down.
22 W415-0619 / B / 03.03.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces GT8P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces GT8P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces GT8P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces GT8P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces GT8P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces GT8P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces GT8P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces GT8P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.