Manuel d'utilisation / d'entretien du produit GD82PT du fabricant Napoleon Fireplaces
Aller à la page of 34
1 W415-0536 / C / 09.06.06 W415-0536 / C / 09.06.06.
2 W415-0536 / C / 09.06.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0536 / C / 09.06.06 PG2-6 INTRODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 6-10 vENTING V ent lengths.
4 W415-0536 / C / 09.06.06 ALL SPECIFICA TIONS AND DESIGNS ARE SUBjECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915.
5 W415-0536 / C / 09.06.06 .
6 W415-0536 / C / 09.06.06 24" 16" 8" Expansion / contraction nosies during heating up and cooling down cycles are normal and are to be expected.
7 W415-0536 / C / 09.06.06 ver tical rise in feet v T figure 4 when (H T ) < (v T ) (only one 90° elbow) See graph to determine the required vertical rise v T for the required horizontal run H T .
8 W415-0536 / C / 09.06.06 H 2 H 1 v 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . v 1 = v T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03 (tw o 90° e lb ows - 9 0°) = . 03( 18 0° - 90 °) = 2.
9 W415-0536 / C / 09.06.06 required ver tical rise in feet v T horizont al vent run Plus offset in feet H T when (H T ) < (v T ) figure 9 .
10 W415-0536 / C / 09.06.06 figure 12.
1 1 W415-0536 / C / 09.06.06 This application occurs when venting through a ro of. I nsta lla tion k its for various roof pitches are available from your Napoleon dealer . See Access ories to order the 1.
12 W415-0536 / C / 09.06.06 .
13 W415-0536 / C / 09.06.06 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼” clearance between the outer and inner vent pipes.
14 W415-0536 / C / 09.06.06 flue collar restrictor pla te top of tHe firebox .
15 W415-0536 / C / 09.06.06 WARNING F acing and/or finishing material must ne ver o verhang into the fireplace opening. Do not distor t or force the fr ame kit components. W hen using a rough finish materi - al (i.e.; stone), maintain a ¼” - ½” bor der from the framing components.
16 W415-0536 / C / 09.06.06 figure 32 MANTLE CLEARANCES 0 3 4 7 8 9 1 1 13 1 2 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the man- tle depth. Use the graph to help evaluate the clearance needed.
17 W415-0536 / C / 09.06.06 4. Pla ce log #4 with the charred branch facing inwa rd. Positio n the pin in log #4 into the hole on the right of log #2. 5 . P l a c e l o g # 5 s o the locating hole on the botttom of the log sits on the screw and spacer .
18 W415-0536 / C / 09.06.06 BLOWER MOUNTING PLA TE REMOVE 4 SCREWS BL O WER REPLA CEMENT The Napoleon P ARK A VENUE comes equipped with a heat circ ulatin g bl ower . The blo wer is pre- wired and is controll ed by the remote control supplied with the unit.
19 W415-0536 / C / 09.06.06 1. Carefully remove the glass door and all logs. (Refer to the installation manual) 2. Remove the two screws holding the front portion of the . Remove the pilot shield by removing the two screws as illustrated.
20 W415-0536 / C / 09.06.06 1. Attach screw and spacer as illustrated in Fig. 46 to the bottom of both sides of the front housing. 2. Attach the face plate bracket provided to the top edge of the front housing using 2 #8 - 1/2” truss head screws as illustrated in Fig.
21 W415-0536 / C / 09.06.06 REMO TE, RECEIvER AND v AL vE ACCESS 1a. Rectangular Front Removal .
22 W415-0536 / C / 09.06.06 running and the gas valve turned to the “ON” position.
23 W415-0536 / C / 09.06.06 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6.
24 W415-0536 / C / 09.06.06 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address.
25 W415-0536 / C / 09.06.06 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) figure 64.
26 W415-0536 / C / 09.06.06 A. T lit by hand while following these instructions exactly . B.
27 W415-0536 / C / 09.06.06 AIR SHUTTER OPENING lead to carboning.
28 W415-0536 / C / 09.06.06 This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther- mocouple supplied by Wolf Steel Ltd.
29 W415-0536 / C / 09.06.06 44 43 56 55 53 19 9 22 21 20 18 23 32 62 68 AUX ON 0:00 00 ON/OFF FEATURE SELECT 63 26 24 25 27 36 35 2 13 1 1 15 14 12 66 49 50 51 7 1 3 4 52 67 5 6.
30 W415-0536 / C / 09.06.06 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- .
31 W415-0536 / C / 09.06.06 Remote wall switch is in “OFF” main burner comes on when gas knob i s t u r n e d t o “ O N ” position. W all switch is mounted up- side down - reverse. Faulty valve. - replace. - replace.
32 W415-0536 / C / 09.06.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
33 W415-0536 / C / 09.06.06 NOTES.
34 W415-0536 / C / 09.06.06 NOTES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces GD82PT c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces GD82PT - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces GD82PT, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces GD82PT va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces GD82PT, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces GD82PT.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces GD82PT. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces GD82PT ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.