Manuel d'utilisation / d'entretien du produit BGD48N du fabricant Napoleon Fireplaces
Aller à la page of 28
W415-0326 / C / 1 1.23.07 1 W415-0326 / C / 1 1.23.07 $10.00.
W415-0326 / C / 1 1.23.07 2 Framing Minimum Mantel and Enclosure Clearances Nailing T ab Installation 19-20 FINISHING Log Placement Charcoal Embers V ermiculite Glowing Embers Logo Placement Louvre In.
W415-0326 / C / 1 1.23.07 3 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.
W415-0326 / C / 1 1.23.07 4 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
W415-0326 / C / 1 1.23.07 5 FIGURE 1 INST ALLA TION O VER VIEW FIGURE 2.
W415-0326 / C / 1 1.23.07 6 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components.Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to.
W415-0326 / C / 1 1.23.07 7 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 3.
W415-0326 / C / 1 1.23.07 8 FIGURE 5 SPECIAL VENT INST ALLA TIONS NO TE: When ter minating v er ticall y , the restrictor plate W500- 0205 must be installed. R efer to R estricting Vertical V ents. PERISCOPE TERMINA TION TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS FIGURES 4 a-b Use only GD401 periscope kit to locate the air termination above grade.
W415-0326 / C / 1 1.23.07 9 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertica.
W415-0326 / C / 1 1.23.07 10 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFF- SETS IN FEET (H T ) FIGURE .
W415-0326 / C / 1 1.23.07 11 V 1 HORIZONT AL TERMINA TION See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
W415-0326 / C / 1 1.23.07 12 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03 (one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.
W415-0326 / C / 1 1.23.07 13 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2.
W415-0326 / C / 1 1.23.07 14 FIGURE 16 14 7 /16" W x 16 1 /4" H. See fi gure16. This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required.
W415-0326 / C / 1 1.23.07 15 FIGURE 25 4. Insert the liners through the fi restop maintaining the required clearance to combustibles. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not supplied).
W415-0326 / C / 1 1.23.07 16 FIGURE 31 RESTRICTOR PLA TE TOP OF THE FIREBOX FLUE COLLAR The vent system must be supported approximately every 3 feet for both vertical and horizontal runs.
W415-0326 / C / 1 1.23.07 17 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi re- place when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
W415-0326 / C / 1 1.23.07 18 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Cur- tains, above the fi replace, must not be positioned lower than the 2" distance required for the 2" combustible mantel.
W415-0326 / C / 1 1.23.07 19 NAILING TA B FIGURE 39 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
W415-0326 / C / 1 1.23.07 20 B A Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers.
W415-0326 / C / 1 1.23.07 21 FIGURE 50 FIGURE 45 INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in accord- ance with local codes.
W415-0326 / C / 1 1.23.07 22 When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.
W415-0326 / C / 1 1.23.07 23 Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.
W415-0326 / C / 1 1.23.07 24 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE ** 4 W010-0796 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0797 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008.
W415-0326 / C / 1 1.23.07 25.
W415-0326 / C / 1 1.23.07 26 TR OUBLE SHOO TING GUIDE Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed.
W415-0326 / C / 1 1.23.07 27 SYMPT OM PROBLEM TEST SOLUTION Flames are consist- ently too large or too small. Carboning oc- curs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
W415-0326 / C / 1 1.23.07 28 NO TES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces BGD48N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces BGD48N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces BGD48N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces BGD48N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces BGD48N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces BGD48N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces BGD48N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces BGD48N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.