Manuel d'utilisation / d'entretien du produit KHLDV400 du fabricant Monessen Hearth
Aller à la page of 64
73D0024 3/10 Rev .
2 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 3 KHLD V Ser ies G as Fi replace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5.
4 73D0024 KHLD V Ser ies G as Fi replace Continued from page 3 15.
73D0024 5 KHLD V Ser ies G as Fi replace • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels.
6 73D0024 KHLD V Ser ies G as Fi replace D E J H O P - Min.
73D0024 7 KHLD V Ser ies G as Fi replace Read this homeowner manual thoroughly and follow all instructions carefully .
8 73D0024 KHLD V Ser ies G as Fi replace Plan for the installation of your appliance.
73D0024 9 KHLD V Ser ies G as Fi replace 72” (1829 mm) Minimum Ceiling 12” (305 mm) Max. Depth 2 1 / 2 ” Max Depth (64 mm) 10” (254 mm) Min.From Opening 16” (406 mm) Min. From Opening FP2128 mantel clearances 6” (152 mm) Min. Hearth 8” Min.
10 73D0024 KHLD V Ser ies G as Fi replace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor . Use four (4) screws to attach fireplace to framing.
73D0024 1 1 KHLD V Ser ies G as Fi replace Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation.
12 73D0024 KHLD V Ser ies G as Fi replace There are two basic typ.
73D0024 13 KHLD V Ser ies G as Fi replace V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
14 73D0024 KHLD V Ser ies G as Fi replace 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 2 4 6 8 10 12 14 16 18 20 eg: A FP2132 sidewall ven t graph V G G=6" (152mm) F F=6" (152mm) .
73D0024 15 KHLD V Ser ies G as Fi replace Locate vent opening on the wall.
16 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 17 KHLD V Ser ies G as Fi replace Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° T otal Angular V ariati.
18 73D0024 KHLD V Ser ies G as Fi replace If the fo un dat ion is re cess ed, us e rece ss brack ets (not supplied) for securing lower portion of the snorkel. Fasten brack- ets to wall first, then secure to s n o r k e l w i t h self drilling #8 x 1/2 sheet metal s c r e w s .
73D0024 19 KHLD V Ser ies G as Fi replace Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° T otal Angular V ariation = 270° 24" Min.
20 73D0024 KHLD V Ser ies G as Fi replace 2. Assemble the desired lengths of pipe and elbows nec- essary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked.
73D0024 21 KHLD V Ser ies G as Fi replace Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace.
22 73D0024 KHLD V Ser ies G as Fi replace A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance.
73D0024 23 KHLD V Ser ies G as Fi replace FP1979 Millivolt gas valv e 1.
24 73D0024 KHLD V Ser ies G as Fi replace ON OFF OPTIONAL REMOTE W ALL SWITCH PILOT HI LO ON OFF TH TP TH/TP ON OFF RS FP1980 Dv wiring diagram A remote wall switch and up to fifteen (15) feet of 18 Ga.
73D0024 25 KHLD V Ser ies G as Fi replace Junction Box Blower Rheostat T -Stat Sensor Right Blower Left Blower White Black Hi-T emp Black Black Hi-T emp Black Black FP2135 blower wiring diagram Blue Blue 7. Remove the access covers on the right and left side walls of the firebox toward the front by unfastening the screws.
26 73D0024 KHLD V Ser ies G as Fi replace FP2137 blower acc ess plates Clip Firebox.
73D0024 27 KHLD V Ser ies G as Fi replace This applianc e is equ ipped with a pilot whic h must be lit with built-in piezo ignito r while follo wing these instructions exactly . BEFORE OPERA TING smell all around the appliance area for gas.
28 73D0024 KHLD V Ser ies G as Fi replace Continued on next page Y ou may check for gas leaks with the following.
73D0024 29 KHLD V Ser ies G as Fi replace The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace.
30 73D0024 KHLD V Ser ies G as Fi replace 1. Check gas type.
73D0024 31 KHLD V Ser ies G as Fi replace 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit.
32 73D0024 KHLD V Ser ies G as Fi replace A/C Module Control Board RF Receiver ON/OFF Button Pilot Black / Thermopile Red / Thermopile Sensor Ignitor / Sparker Conversion NG/LP Plug-in Connector Contr.
73D0024 33 KHLD V Ser ies G as Fi replace To Junction Box I.
34 73D0024 KHLD V Ser ies G as Fi replace This appliance is equipped with an ignition device which automatically lights the pilot.
73D0024 35 KHLD V Ser ies G as Fi replace 1. Read the safety information above.
36 73D0024 KHLD V Ser ies G as Fi replace • Easy Access Function Operation and System Configura- tion • Operation Confirmation/.
73D0024 37 KHLD V Ser ies G as Fi replace .
38 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 39 KHLD V Ser ies G as Fi replace .
40 73D0024 KHLD V Ser ies G as Fi replace Figure 51 The remote transmitter privacy code is preset in facto- ry .
73D0024 41 KHLD V Ser ies G as Fi replace 1. Press the ON/up button to turn on the fireplace. The flame icon on the LCD displays High. 2.
42 73D0024 KHLD V Ser ies G as Fi replace is no manual flame height adjustment. The fan speed will also automatically adjust if turned on.
73D0024 43 KHLD V Ser ies G as Fi replace n 1. Low Battery Detection When low battery condition occurs, the transmitter will turn off the fireplace. A) Battery voltage is checked every one min- ute. When the battery voltage is low , the LCD displays a low battery icon which will exist in all modes.
44 73D0024 KHLD V Ser ies G as Fi replace n The transmitter comes with a mounting base which allows you to hang the transmitter on the wall.
73D0024 45 KHLD V Ser ies G as Fi replace 1. Remove the plate located in front of the glass at the bottom. 2. Remove rod provided for screen assembly located beneath the cover plate.
46 73D0024 KHLD V Ser ies G as Fi replace 1. Place rock wool on the front burner to provide glowing embers. For best results, pull the rock wool apart into dime size pieces and place on top of burner .
73D0024 47 KHLD V Ser ies G as Fi replace Burner Grate Assembly L G593 KHLDV grate LG593 Step 1 L G594 KHLDV rear log LG594 1. Place the rear log over the grate toward the back by positioning the holes over the large pins located at the right and left.
48 73D0024 KHLD V Ser ies G as Fi replace 4. Place the middle log over the two burners by setting the flat surface over the burner and matching the indenta- tion located underneath the branch over the protrusion loc ated at V -br anc h on the le ft fr on t log plac ed in ste p #3.
73D0024 49 KHLD V Ser ies G as Fi replace The flames from the burner should be visually check ed as soon as the heater is installed and periodically during normal operation.
50 73D0024 KHLD V Ser ies G as Fi replace The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person.
73D0024 51 KHLD V Ser ies G as Fi replace 1.
52 73D0024 KHLD V Ser ies G as Fi replace 4.
73D0024 53 KHLD V Ser ies G as Fi replace OPERA TION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON pos.
54 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 55 KHLD V Ser ies G as Fi replace .
56 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 57 KHLD V Ser ies G as Fi replace 730024 KHLDV SG par ts 12/08 1 .
58 73D0024 KHLD V Ser ies G as Fi replace .
73D0024 59 KHLD V Ser ies G as Fi replace 1. Log #1 1 73D0539 73D0200 2.
60 73D0024 KHLD V Ser ies G as Fi replace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts .
73D0024 61 KHLD V Ser ies G as Fi replace x For more information about, or instructions for , the venting components referenced above, please contact the component manufaturer: Selkirk Corporation: www .
62 73D0024 KHLD V Ser ies G as Fi replace This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
73D0024 63 KHLD V Ser ies G as Fi replace The fol.
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com KHLDV400NV 69.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Monessen Hearth KHLDV400 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Monessen Hearth KHLDV400 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Monessen Hearth KHLDV400, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Monessen Hearth KHLDV400 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Monessen Hearth KHLDV400, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Monessen Hearth KHLDV400.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Monessen Hearth KHLDV400. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Monessen Hearth KHLDV400 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.