K aleido-K2 High Resolution Vir tual Monit or W all Pr oc essor Guide to Installation and Operation M406-9900-402 Copyright 2006 Miranda T echnologies Inc. Specifications may be subject to change. Printed in Canada November 2006 K aleido-K2 Mirand a T echnologies inc.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 Safety Compliance Information Safety Compliance This equipment complies w ith: - CSA C22.2 No. 60950-1-03 / Safet y of Information Techno logy Equipment, Including El e ctrical Business Equipment.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 Contents 1 Kaleido-K2 High Resolution Virtual Monitor Wall Processor .................................................................... 1 1.1 Intr oduction ..............................................
GUIDE TO INSTALLATION AND OPERATION Kaleido K2.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 1 1 Kaleido-K2 Ultra High Resoluti on Virtual Monitor Wall Processor 1.1 Introduction The Kaleido-K2 Ultra High Resolution V irtual Monito r Wall Proc essor is designed as the ultimate solution to s ignal monitoring requirement s.
GUIDE TO INSTALLATION AND OPERATION 2 | Kaleido K2 Figure 1.2.1 Kale ido-K2 functional block dia gram REF Input.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 3 2 Overview 2.1 Front Panel The front panel of the Kaleido-K2 has three operationa l elements: - ON/OFF pushbutton - System status indicator L E D - CPU reset button. These items are actually located on the front edge of t he controller card.
GUIDE TO INSTALLATION AND OPERATION 4 | Kaleido K2 3 Mechanical Installation 3.1 Unpacking Make sure the following items have be e n shipped with y our Kaleido.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 5 Figure 3.2.2 Movin g the connecto r Once the DE-9 connector is installed in the prop er opening a nd the unit reassembled, do the following: - Remove the 4 rubber feet on the underside of the unit. - Place the Kaleido-RCP into the mounting bracket and secure it using the supplied screws (figure 3.
GUIDE TO INSTALLATION AND OPERATION 6 | Kaleido K2 4 Frame and Electri cal Installation Kaleido is a self-contained unit consisting of a frame, redundant po wer supplies, a controller card, and va rio us input and output cards. 4.1 Frame The frame is 4 RU high.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 7 4.2.2 Operation Connect each power supply to a power source usi ng the supplied power cords. In normal operation, both supplies should be switched ON (power switch on the power supply unit set to | ).
GUIDE TO INSTALLATION AND OPERATION 8 | Kaleido K2 4.3.1 Connector panel installation Remove the blank panel (a blank pan el is used to occ upy the rear panel space behin d empty slots) or existing connector panel. Release the captive screws at the to p and bottom, and pull the panel straight out of the frame.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 9 The location of the connectors differs between input a nd output cards, so placi ng the wrong type of card in a slot is simply not possible.
GUIDE TO INSTALLATION AND OPERATION 10 | Kaleido K2 The rear connector pan el (11) associated with the Controller module has the foll owing connectors: Ethernet: RJ-45 connecto r Ethernet interface for connection to LAN/WAN networks usin g TCP -IP. RS-422/485: DE-9S connector For connecting the Kaleido-RCP or other remot e cont rol devices.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 11 Green indicates that the unit is properly power ed and that one or both power su pplie s are on. Red indicates a stand-by mode: the unit is plug ged in but the Controller is not switched o n.
GUIDE TO INSTALLATION AND OPERATION 12 | Kaleido K2 4.4.2 GPI Module The GPI module provides interfaces and processin g to support 66 contact closure tally inputs and 36 contact closure alarm outputs. Four DC-37S con necto rs are in stalled on the MWR-GPI rear connector panel (10 ).
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 13 GPI inputs characteristics: Signal: 64 short-to-ground inputs Connecto r: DC-37S GPI outputs characteristics: Signal: 66 opto-isolated co ntact closures Connecto r: DC-37S Characte ristics: Max differential voltage: 12 VDC Max s ink current: 70 mA Isolation voltage: 2500 VRMS Figure 4.
GUIDE TO INSTALLATION AND OPERATION 14 | Kaleido K2 4.4.3 Analog Audio Input Module (MWI-S A) This module provides inpu t s for 16 chan nels of analog stereo audio. Two DS UB 50 connectors are avail abl e on the MWR-SA rear connection panel (8). Figure 4.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 15 4.4.4 Digital Audio Input Module (MWI-AES ) This module provides inputs for 16 channels of AES/EBU digi tal audio. A single DSUB 50 connector is available on the MWR-AES rear conne ction pa nel (9 ).
GUIDE TO INSTALLATION AND OPERATION 16 | Kaleido K2 Figure 4.4.5.1 MWI-CVBS rear connector panel 4.4.6 Y/C Analog Video I nput Module (MWI-YC) This module provides inpu t s for 4 ch annels of Y/C (S -video) analog video. The inputs are mini-DIN 4-pin connectors, internally terminated and available on the MWR-YC rear connection module (5).
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 17 Figure 4.4.7.3 MWA-BOC cable adapter 4.4.8 Digital Video SD-SDI Input Module (M WI-SDI ) This module provides inpu t s for four cha nnels of serial digital video. The inputs are on BNC connectors and are available on the MWR-4B rear connecti on module (2).
GUIDE TO INSTALLATION AND OPERATION 18 | Kaleido K2 Figure 4.4.8.2 DE-1 5P connector pinout 4.4.10 HD-SDI Video Input Module (MWI-HD) This module provides three standard - and high-definition digital video inputs.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 19 Figure 4.4.11.2 Audio mo nitoring connector pinout MON OUT: Provision for Monitoring output in SDI or Composite. Two slots are provided in the frame fo r the installation of output modules, increasing the flexibility of output management.
GUIDE TO INSTALLATION AND OPERATION 20 | Kaleido K2 Figure 4.5.1 Cascadin g two Kaleido-K2s Figure 4.5.1.1 Controlling multiple Kale ido-K2s through an ethe rnet network.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 21 4.5.2 Controlling multiple Kaleido-K 2s using RS-42 2 with a Kaleido-RCP Using the RS-422 comm unication port also allows up to 99 daisy-chained Kalei do -K2 frames to be controlled using only one Kaleido-RCP.
GUIDE TO INSTALLATION AND OPERATION 22 | Kaleido K2 5 Operation The function of Kaleido-K2 is to gather information from multiple sources and merge it into a single inform ation stream for presentation on a monitor. This process is managed un der softwa re control.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 23 6 Maintenance 6.1 Cleaning the air filter Occasionally, the air filter has to be removed and properly cleaned i n order to maintain proper ventilation. To remove and clean the air filter, follow these directions: 1.
GUIDE TO INSTALLATION AND OPERATION 24 | Kaleido K2 5. Remove the 4 screws that hold the fan onto the bracket, t hen remove the fan. 6. Install the new fan using the 4 retaining screws. 7. Plug in the fan power connector. Reinsta ll the fan bracket and the con nector panels.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 25 7 Specifications INPUT COMPOSITE VIDEO INPUT (MWI-CVB S) SIGNAL (4): NTSC (SMPTE 170M), PAL, PAL-M, PAL-NITU 624-4, SECAM RETURN LOSS: > 35 dB up to 5.
GUIDE TO INSTALLATION AND OPERATION 26 | Kaleido K2 SCALES: EBU DIGITAL PPM (IEC-6026 8-18), NORDIC (IEC-60268-10 TYPE I), BBC/UK PPM(IEC-60268-10 TYPE IIA), EBU PPM (IEC-60268-10 TYPE IIB) PROGRESSIV.
GUIDE TO INSTALLATION AND OPERATION Kaleido K2 | 27 OUTPUT PROGRESSIVE RGBHV OUTPUT 1 (MWO-HR) SIGNAL: Analog RGBHV RESOLUTION: From 800 x 600 to 1600 X 1200 NI H FREQUENCY: 31 kHz to 96 kHz REFRESH RATE: 50/59.94 Hz CABLE LENGH: 5m (low), 20m (medium) and 50m (hig h) cables built-in equalize r (Belden 1694) LEVEL: Selectable 0.
GUIDE TO INSTALLATION AND OPERATION 28 | Kaleido K2 REMOTE PORT (MWA-CPU) DESCRIPTION: Remote control panel communication port SIGNAL: RS-422 (SMPTE 207M, EBU-3245), RS-485 with 12V supply on pin 5 CONNECTOR: DE-9S (female) ETHERNET PORT(MWA-CPU) SIGNAL: 10/100 BASE-T (IEEE 802.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Miranda Camera Co M406-9900-402 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Miranda Camera Co M406-9900-402 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Miranda Camera Co M406-9900-402, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Miranda Camera Co M406-9900-402 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Miranda Camera Co M406-9900-402, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Miranda Camera Co M406-9900-402.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Miranda Camera Co M406-9900-402. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Miranda Camera Co M406-9900-402 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.