Manuel d'utilisation / d'entretien du produit Stratos MS2x20 Series du fabricant Metrologic
Aller à la page of 92
METROLOGIC INSTRUMENTS, INC. MS2 x 20 Stratos ® Series Configuration Addendum Mettler Toledo Diva Scale.
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS I MPORTANT N OTES - B EFORE Y OU S TART ................................................................. 1 Important Bar Codes Scale Save Data Bar C ode .................................................................... 2 Scale Type Ba r Code .
iii T ABLE OF C ONTENTS Single Cable Scanner Protocols for P.O.S. Compatibility MSS Gl obal .......................................................................................... 27 ISS45 ...........................................................
iv T ABLE OF C ONTENTS Auxiliary Port Stratos SCHOOL ™ ............................................................................... 61 Quick Start for a Secondar y Metrologic Scan ner ................................. 62 EAS Bar Codes EAS Device Types .
1 I MPORTANT N OTES - B EFORE Y OU S TART It is important to read carefully the notes marked with a symbol on the pages contained in this manual. Not all conf igur ation codes are designed to be us ed for both a single and dual cable s canner/scale system.
2 I MPORTANT N OTES - B EFORE Y OU S TART Important Bar Codes Scale Save Data Bar Code. The Scale Save Data bar code must be scanned l ast to “save” the changes in the scale’s memory. The scale will then reset and beg in normal operation. This is required only for scale configurat ion items – not for calibration.
3 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds ) For Kilogram weight units see pag e 4.
4 S CALE /L OAD C ELL C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Kilograms ) For Pound weight units see page 3.
5 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
6 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Pole Display Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
7 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
8 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
9 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Scale Internal Beeper The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
10 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Zero Cursor The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
11 S CALE C ONFIGURATION B AR C ODES Single or Dual Cable Scale Configuration Bar Codes Quantitative Separator The following bar codes can be used to confi gure a Single or Dual Cable MS2 xx 0. If the MS2 xx 0 is currently in a Dual Cable configuration, temporaril y disconnect the Scale to Host cable prior to configurin g the scale.
12 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
13 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
14 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
15 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
16 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
17 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 24.
18 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment.
19 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment.
20 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
21 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
22 S CALE C ONFIGURATION B AR C ODES Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment.
23 S CALE C ONFIGURATION B AR C ODES Single Cable Scale Configuration Bar Codes Set Scale for Single Cable Communication If the MS2 xx 0 is currently in a Dual Cable configuration, disconn ect and remove the Scale to Host cable prior to configurin g the scale.
24 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode The following bar codes can be used to place , as well as configure, the scanner in Dual Cable mode. The MS2xx0 does not need to be in scale service mode to use the following bar codes.
25 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes Various Dual Cable Scanner Mode The following bar codes can be used to confi gure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
26 S CANNER C ONFIGURATION B AR C ODES Dual Cable Scanner Configuration Bar Codes IBM 3 rd Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to confi gure a Dual Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
27 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility MSS Global The following bar codes can be used to confi gure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
28 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility ISS45 The following bar codes can be used to confi gure a Single Cable MS2 xx 0.
29 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility OPOS The following bar codes can be used to confi gure a Single Cable MS2 xx 0.
30 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Retailix/NCR The following bar codes can be used to confi gure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
31 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Retailix/OPOS The following bar codes can be used to confi gure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
32 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IT Retail The following bar codes can be used to confi gure a Single Cable MS2 xx 0.
33 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM Self Checkout System The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
34 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility Various RS232 Single Cable Codes The following bar codes can be used to confi gure a Single Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
35 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM 3 rd Generation 46xx The following bar codes can be used to confi gure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
36 S CANNER C ONFIGURATION B AR C ODES Single Cable Protocols for POS Compatibility IBM OEM Full Speed USB The following bar codes can be used to confi gure a Single Cable MS2 xx 0. The following codes do not require that the MS2 xx 0 to be in scale service mode.
37 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2 xx 0 to be in scale service mode. Scanner 4B Handheld ³ 31643 0 Full Speed USB interface to 4B00h handheld usage.
38 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2 xx 0 to be in scale service mode. Scanner/Scale 4A/6E Table Top ³ 31644 0 Full Speed USB interface to the 4A00h/6E00h table top scanner/scale usage.
39 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2 xx 0 to be in scale service mode. Enable Special Function ACK Answer ³ 14171 4 Answer simple special functions with ACK.
40 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Prefix/Suffix The following codes do not require that the MS2 xx 0 to be in scale service mode. Use Protocol Prefix/Suffix ³ 14171 5 Add protocol prefixes and suffixes to the bar code.
41 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3x-30 Acknowledge Responses The following codes do not require that the MS2 xx 0 to be in scale service mode. No 3x-30 Answer ³ 14171 0 This bar code will inhibit all ‘simple acknowledge’ (3x- 30) answers to POS or OPOS commands.
42 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2 xx 0 to be in scale service mode. Spec Func Ans 3x30 ³ 14191 4 Answer Special Function commands i n the 3x-30 format as opposed to the Ack / Nak which is the norm.
43 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func 30-30 Status ³ 14221 5 Returns Special Function commands in the 30-30 status as opposed to the 33-30 statu s.
44 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Command Reject Answer ³ 14211 7 This bar code will ignore sending a command reject answer to the POS mode.
45 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Spec Func Answer ³ 14211 6 This bar code will ignore sendin g a special function response answer in POS mode.
46 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting BCC in POS communications The following codes do not require that the MS2 xx 0 to be in scale service mode. Skip BCC in messages ³ 14141 0 This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions.
47 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting 3 Scale Status Bytes The following codes do not require that the MS2 xx 0 to be in scale service mode.
48 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Scale Options The following codes do not require that the MS2 xx 0 to be in scale service mode. 5-Digit Weight ³ 14101 0 Sets the English Mode weight to 5-digits, as in xx.yyy pounds.
49 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting Remote Display The following codes do not require that the MS2 xx 0 to be in scale service mode.
50 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2 xx 0 to be in scale service mode. Activate StratosSTATS ³ 99701 7 This bar code sets: a. StratosSTATS bar code data formatting active.
51 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode.
52 S CANNER C ONFIGURATION B AR C ODES Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode.
53 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Beep on Weight Sent The following codes do not require that the MS2 xx 0 to be in scale service mode. Beep on Weight ³ 14191 7 Request scanner beep when a successful weight is sent.
54 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes ³ 12581 0 This bar code places tighter restrictions on in-store codes.
55 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode ³ 14221 7 This bar code sets the scale to the highest priority to allow for frequent scale - POS commands.
56 S CANNER C ONFIGURATION B AR C ODES Additional POS Related Functions Scanner Razz on Not-On-File The following codes do not require that the MS2xx0 to be in scale program mode. Razz on Not-On-File ³ 14211 5 This bar code changes the audible to a razz signal when a Not-On-File command is received.
57 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
58 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
59 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
60 S CANNER C ONFIGURATION B AR C ODES Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative.
61 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Stratos SCHOOL ™ The following codes do not require that the MS2 xx 0 to be in scale service mode. Auxiliary History Report ³ 99701 1 The Auxiliary p ort may be used to download or clear data to Stratos SCHOOL ™.
62 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner The following codes do not require that the MS2 xx 0 to be in scale service mode.
63 S CANNER C ONFIGURATION B AR C ODES Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequ ence cont inued from previ ous page.
64 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. * No EAS Device ³ 33720 0 No EAS device is connected.
65 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 2 ³ 33722 0 EAS Device Type 3 ³ .
66 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 4 ³ 33724 0.
67 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. * EAS = 0 seconds ³ 84600 0 * Factory Default Setting .
68 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 2 seconds ³8 4 6 0 0 2 0 0 EAS = 3 seconds ³8 4.
69 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 4 seconds ³8 4 6 0 0 4 0 0 EAS = 5 seconds ³8 4.
70 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 7 seconds ³8 4 6 0 0 7 0 0 EAS = 10 seconds ³8 .
71 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 15 seconds ³8 4 6 0 1 5 0 0 EAS = 20 seconds ³8.
72 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. * EAS Digital Aux Port ³ 14610 0 The EAS signals use the RTS and CT S line of the Auxiliary RS232 In connector.
73 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Aux Port ³ 14611 1 This bar code allows the EAS RS232 si gnal to use the Tx Out and Rx In lines of the scanner to Aux RS232 In connector.
74 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Connection The following codes do not require that the MS2xx0 to be in scale program mode. EAS RS232 on Host Port ³ 14611 2 This bar code allows the EAS RS232 si gnal to use the Tx Out and Rx In lines of the scanner to Host RS232 In connector.
75 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Continuous Mode The following codes do not require that the MS2xx0 to be in scale program mode. EAS Continuous Mode ³ 14611 5 When in continuous mode an d the scanner is enabled, the EAS will always be online to deactivate an EAS tag.
76 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Blink Scan LED on Deactivation ³ 14611 3 The scanner will blink the sca n LED upon receipt of an EAS deactivate acknowledge signal.
77 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Fast Beep on Deactivation ³ 14611 4 Fast beep the scanner’s beeper recei pt of an EAS deactivate acknowledge sign al.
78 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Volume Switch = Manual ³ 14611 6 The volume switch is used for manual EAS deactivation switch. * Volume Switch = Normal ³ 14610 6 Volume switch is used for normal vol ume function.
79 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode.
80 S CANNER C ONFIGURATION B AR C ODES EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode.
81 S CANNER T EST B AR C ODES Supplemental Tests Display Software Numbers The following codes do not require that the MS2 xx 0 to be in scale service mode. These codes are for test purposes only. The following code will displa y software #’s on the 2-digit diagnostic displa y.
82.
N OTES.
N OTES.
.
.
May 2008 Printed in the USA 00 - 02272 C.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Metrologic Stratos MS2x20 Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Metrologic Stratos MS2x20 Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Metrologic Stratos MS2x20 Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Metrologic Stratos MS2x20 Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Metrologic Stratos MS2x20 Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Metrologic Stratos MS2x20 Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Metrologic Stratos MS2x20 Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Metrologic Stratos MS2x20 Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.