Manuel d'utilisation / d'entretien du produit PCI Internal Voice/FAX/Data/Speakerphone Modem du fabricant MaxTech
Aller à la page of 21
Part #MAN152 Rev. 1.0 V.90-CL High Performance V .90/V .34+/V .42bis 56K BPS PCI Internal V oice/F AX/Data/ Speakerphone Modem User's Manual Contents Section One - Introduction .......................... 1 Section T wo - Installation ............
The information contained in this manual has been validated at the time of this manual's production. The manufacturer reserves the right to make any changes and improvements in the product de- scribed in this manual at any time and without notice.
1 Section One - Introduction The MaxTech XPVS56P/C PCI Plug and Play Data, Fax, Voice Speakerphone Modem connects your com- puter to all popular high speed modems available today. The modem utilizes V.90 (56Kbps) technology to provide increased download speeds using regular telephone lines.
2 2.3 Hardware Installation Installation of this modem requires opening and manipulating your PC. Exercise caution at all times when working with AC powered and static-sensitive equip- ment.
3 2 . 4 Hardware Configuration The version of Windows 9x you have will determine which set of dialog boxes is presented to you when installing the modem in Windows 9x. Proceed to one of the following sections, depending on your Windows 9x's diaglog box: • Section 2.
4 2.4.1.2 Windows 98 When Windows 98 starts for the first time after card installation, it detects the adapter and displays the Add New Hardware Wizard.
5 software. Consult the software manual for information on using these and other parameters/features. 115,200 bps; 8 data bits; no parity; 1 stop bit; RTS/CTS flow control set to “on;” initializat.
6 2.8 Where To Go From Here You should familiarize yourself with the functions available from the included software by reading its manual. You will be accessing most, if not all, of the modem's functions from this software. You may also use any other commercially available communication soft- ware with the modem.
7 3.3 Basic AT Commands In the following listings, all default settings are printed in bold text. Command Function A Manually answer incoming call A/ Repeat last command executed. Do not precede A/ with AT or follow with ENTER AT Appears at the beginning of every command line B_ B0 CCITT mode B 1 Bell mode B2 V.
8 I 5 Modem chip hardware configuration I 6 Country code I 7 Board manufacturer firmware version I 8 Modem firmware version I 1 0 Modem board configuration L_ L0 Low speaker volume L1 Low speaker volu.
9 X1 Same as X0 plus all CONNECT responses/ blind dialing X2 Same as X1 plus dial tone detection X3 Same as X1 plus busy signal detection/ blind dialing X 4 All responses and dial tone and busy signal.
10 &Q_ &Q 0 Modem in asynchronous mode &S_ & S0 Force DSR Signal High (ON) &S1 DSR is off in command mode, on in on-line mode &T _ &T 0 Ends test in progress &T 1 Perform Local Analog Loopback Test &U_ &U 0 Enable Trellis Coding @ V.
11 % E 1 V.22bis auto-retrain enabled %E 2 Enable line signal quality monitor and fallback/fallforward % G_ % G0 Enable Auto Fall Forward/Back %G1 Disable Auto Fall Forward/Back -C _ -C 0 Calling tone disabled -C1 1300hz calling tone -C2 V.8 and 1300hz calling tones enabled 3.
12 Default is 5 N_ N 0 Normal data-link only N 1 Normal data-link only N 2 MNP data link only N 3 V.42/MNP/Normal data link N 4 V.42 data link only O Initiate reliable link during a normal link Q_ Q0 .
13 +FTH=n Transmit HDLC data +FTM=n Transmit data +FTS=n Stop transmission and pause 3.7 ISO 101 Voice Mode Commands +FCLASS=8 Voice modem select +FLO Flow control select +VBT=n Buffwe threshold setti.
14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255/rings 0 S1 Ring counter 0-255/rings 0 S2 Escape code character 0-127/ASCII 4 3 S3 Carriage return character 0.
15 CONNECT 33600 6 6 CONNECT 37333 3 4 CONNECT 38400 2 8 CONNECT 41333 3 5 CONNECT 42666 3 6 CONNECT 44000 3 7 CONNECT 45333 3 8 CONNECT 46666 3 9 CONNECT 48000 4 2 CONNECT 49333 4 3 CONNECT 50666 5 3.
16 Modem does not dial. 1 . Make sure the modem is connected to a working phone line. Replace the modem with a working phone to ensure that the phone line is working. Modem dials but does not connect. 1 . Make sure the IRQ setting is identical on both the modem AND the software.
17 Modem experiences bursts of errors or suddenly disconnects while communicating with a remote modem. 1 . Make sure Call Waiting is turned off. 2 . Make sure the phone line does not exhibit excess noise.
18 the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
19 Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an accept- able method of connection.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei MaxTech PCI Internal Voice/FAX/Data/Speakerphone Modem ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.