Installation Instructions and Homeowner ʼ s Manual 10007317 1 1/05 Rev . 4 INST ALLER: DO NOT DISCARD THIS MANUAL - LEA VE FOR HOMEOWNER Builder Rear V ent Direct V ent Models: 33LDVR, 36LDVR, 39LDVR, 43LDVR DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 LDVR Series Direct Vent Gas Fireplace 10007317 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Specialty Home Products fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 LDVR Series Direct Vent Gas Fireplace 10007317 This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code.
4 LDVR Series Direct Vent Gas Fireplace 10007317 Fireplace Dimensions F V - Rough Opening Width Rough Opening Height Rough Opening Depth S S U T R E I H J D A Q B K L G M O Gas Line Access Gas Line Access Low V oltage Electrical Access Electrical Access C Centerline of 7" Collar M N P Low V oltage Access Fig.
5 LDVR Series Direct Vent Gas Fireplace 10007317 T op of Unit to Ceiling ............................. 36” (914mm) Appliance T op ....................................................... 0” (0 mm) Bottom ............................................
6 LDVR Series Direct Vent Gas Fireplace 10007317 Max. Min. Inp ut Input Mod el Fuel Gas Control BTU/h BTU/h 33LD VRRN Nat Millivolt 16, 00 0 11,200 33LDVRR P Pro p Millivolt 16,000 1 2,000 33LDVREN Na.
7 LDVR Series Direct Vent Gas Fireplace 10007317 Installation 1. Thread the wiring through the holes on the end panels of the fireplace. T ake care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.
8 LDVR Series Direct Vent Gas Fireplace 10007317 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFP A No.
9 LDVR Series Direct Vent Gas Fireplace 10007317 Y our fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components specifi- cally approved and labelled for this fireplace may be used.
10 LDVR Series Direct Vent Gas Fireplace 10007317 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I .
1 1 LDVR Series Direct Vent Gas Fireplace 10007317 Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors.
12 LDVR Series Direct Vent Gas Fireplace 10007317 The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall.
13 LDVR Series Direct Vent Gas Fireplace 10007317 DVR584-600 Rear vent no elbows 2/99 djt 20" (508mm) T op View Straight V enting FP836 Rear V ent-T op View 1 1/21/98 20" (508mm) Max. REAR VENT -TOP VIEW 20" (508mm) Max. T op View Rear V ent Corner Installation Fig.
14 LDVR Series Direct Vent Gas Fireplace 10007317 CFM133 DVR Series T ypical corner install 2/26/01 sta Zero Clearance Sleev e Firestop CFM133 Fig. 17 Firestop and zero clearance sleeve in place. FP1005 Side View V ent T ermination 1/25/00 djt Finished W all V ent T ermi- nation FP1005 Fig.
15 LDVR Series Direct Vent Gas Fireplace 10007317 •IMPORT ANT• Minimum clearance between vent pipes and combustible materials is one (1”) inch (25 mm) on bottom, sides and top. T wist Lock V ent Starter Kit 7TDVSK, plus T ransition Elbow 7TDVRT90 must be used in V ertical Sidewall installations.
16 LDVR Series Direct Vent Gas Fireplace 10007317 V ertical Sidewall Installation STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size.
17 LDVR Series Direct Vent Gas Fireplace 10007317 STEP 6 Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars or the termination one inch away from the end. Guide the vent terminationʼs 4” and 7” collars into their respective vent pipes.
18 LDVR Series Direct Vent Gas Fireplace 10007317 Do not back fill around snorkel. A clearance of at least 4” (102mm) must be maintained between the snorkel and the soil. BG401 Snorkel 2/10/99 djt Foundation Recess Snorkel W all Screws Recess Brackets W atertight Seal Around Pipe Sheet Metal Screws BG401 Fig.
19 LDVR Series Direct Vent Gas Fireplace 10007317 V ertical Through-the-Roof Installation CFM100 Firestop-V ertical 09/20/00 1 1" 1 1" Joist Joist Firestop Spacer Nails (4) Upper Floor Attic Insulation Shield Ceiling Instal- lation CFM100 Fig.
20 LDVR Series Direct Vent Gas Fireplace 10007317 FP1022 T ypical Straight Up Installation 1/26/00 djt 40ʼ (12m) Storm Collar Roof Flash- ing V ent T ermination Roof 2ʼ Min. Roof Support Attic Insulation Shield Attic Insulation Joists Joists FP1022 Fig.
21 LDVR Series Direct Vent Gas Fireplace 10007317 V enting Components 584G V enting Components Firestop spacer 2/25/99 djt 584H V enting components attic insulation shield 2/25/99 djt 584I vent compon.
22 LDVR Series Direct Vent Gas Fireplace 10007317 Only glass approved by CFM Specialty Home Products should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 39) The lower access door is hinged along the bottom edge and is folded down to allow access.
23 LDVR Series Direct Vent Gas Fireplace 10007317 1. Remove the top louvre assembly . 2. Open the bottom louvre. 3. Remove the window frame assembly . 4. Remove log box from inside firebox. 5. Unpack the logs from packaging and remove each log from its wrapping material.
24 LDVR Series Direct Vent Gas Fireplace 10007317 LG383 36LDVR logs 1/05 Rear (B135) Front Left (B136) Front Center (B138) Front Right (B137) LG383 Fig. 42 Correct log placement for 36LDVR. 39LDVR 1. Place rear lob (BC14) on rear bracket (ensure log is centered and seated properly to the log support).
25 LDVR Series Direct Vent Gas Fireplace 10007317 RN/RP & EN/EP Models For units equipped with “HI/LO” valves the flame adjustment is accomplished by rotating the “HI/LO” adjustment knob located near the center of the gas control valve. (Figs.
26 LDVR Series Direct Vent Gas Fireplace 10007317 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace.
27 LDVR Series Direct Vent Gas Fireplace 10007317 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
28 LDVR Series Direct Vent Gas Fireplace 10007317 T roubleshooting - Honeywell Millivolt V alve Remove Window Frame Assembly Before Service Work ST ART CHECK Gas Supply On ▼ ▼ ▼ ▼ ▼ Pilot Lights With Piezo Ignitor • Lockout Has Engaged. W ait 60 Seconds And T ry Again.
29 LDVR Series Direct Vent Gas Fireplace 10007317 T roubleshooting the Gas Control System SIT 822 V alve with Synetek Electronic Control Operating Diagram Normal Operation ON/OFF Switch Closed? Safe S.
30 LDVR Series Direct Vent Gas Fireplace 10007317 The conversion of this appliance from one gas to another must be carried out by an authorized service provider . 1. Disconnect power to the unit and shut off the gas sup - ply . 2. Remove window frame assembly .
31 LDVR Series Direct Vent Gas Fireplace 10007317 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
32 LDVR Series Direct Vent Gas Fireplace 10007317 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
33 LDVR Series Direct Vent Gas Fireplace 10007317 LDVR (continued) Ref. Description 33LDVR 36LDVR 39LDVR 43LDVR 1. Log Set (complete) 10007567 10007318 10008214 10008314 1a. Log Front Left A43 B136 BC15 BD16 1b. Log Front Right -- B137 BC16 BD17 1c. Log Front Center -- B138 B138 B138 1d.
34 LDVR Series Direct Vent Gas Fireplace 10007317 LDVR (continued) Ref. Description 33LDVR 36LDVR 39LDVR 43LDVR 37. Relief Plate Assy (Burner Base) 10004192 10004192 10004192 10004192 38. Remote Switch Kit (Not shown) 53875 53875 53875 53875 39. Ignition Control from Synetek (EN) 10007939 10007939 10007939 10007939 40.
35 LDVR Series Direct Vent Gas Fireplace 10007317 FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air . The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
36 LDVR Series Direct Vent Gas Fireplace 10007317 Ceramic refractory panels are available in kit form for the LDV series appliances Appliance Model Kit Name 33LDVR 33LDVRCR 36LDVR 36LDVCR 39LDVR 39LDV.
37 LDVR Series Direct Vent Gas Fireplace 10007317 Optional T rim Kits Louvre Accent T rim Appliance Model Main Louvre Kit Additional Louvre Polished Brass 33LDVR 33DVLMP 33DVLAP 36LDVR 36DVLMP 36DVLAP.
38 LDVR Series Direct Vent Gas Fireplace 10007317.
39 LDVR Series Direct Vent Gas Fireplace 10007317 BASIC W ARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic .
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 33LDVRRN 62.6 81 82 59 33LDVRRP 62.6 82 83 59 33LDVREN 72.7 81 82 59 33LDVREP 72.7 82 83 59 36LDVRRN 57.5 81 82 58 36LDVRRP 57.5 82 83 58 36LDVREN 63.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Majestic Appliances 43LDVR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Majestic Appliances 43LDVR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Majestic Appliances 43LDVR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Majestic Appliances 43LDVR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Majestic Appliances 43LDVR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Majestic Appliances 43LDVR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Majestic Appliances 43LDVR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Majestic Appliances 43LDVR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.