www.el ectro s team .co m rev. 1228 2009 User Manual & Installation Instruc tion s LG - 10 thru LG -30 IMPORTANT – READ AL L INSTRUCTIONS BEFORE OPERATI NG All st ea m b o il er s are buil t in acco r dance wi t h ASME miniatur e boiler code. NOTE: It is the responsibil it y o f the i n sta l ler to conf or m to any stat e or l oca l co des.
HIG H V OLTAGE AUTHO RIZE D PERS ONN EL ONLY ALTO VO LTAJE SOL A MENTE PERS ON AL AUT ORIZAD O DANGER P ELIGRO CAUTION U S E ELECTRICAL SUPPLY COND UCTORS RAT ED FOR A MINIMUM OF 90° C AMBIENT T EMPERATU RE AROUND UN I T NOT TO EXCEED 105° F TERM I NALS ARE SUITABLE FOR C OPPER WIRE O NL Y U.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 3 o f 33 TABLE OF CON TE NTS 1. ) INSTALLATION INSTRUCTIONS ... ..... ............................................................ 4 2.) OPERATION & SEQUENCE O F EVENTS ............
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 4 o f 33 1.) INSTALLATION INSTRUCTIONS LITTLE GIANT “LG - SERIES” The Electro - Steam Generato r desi g n consists ess ent i ally o f a hi gh pressure c h amber fille d wi th water t hat is h e ated by one o r m or e subm erged res istance type elect ric heat ing elements.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 5 o f 33 2.) OPERATION & SEQUENCE OF EVENTS IMPORTANT – READ INSTALLATION INSTRUCTIONS B EFORE OPERAT ING 1. T ur n o n wat er supply f ro m the sour ce to the Gen erato r . 2. OPEN a ll valves on the Ge nerator except f or the Manual Drain (#19) .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 6 o f 33 3.) CLEANING & MAINTENANCE The f o ll o w ing cleaning procedur es are HIGHLY RE COMM ENDE D in or der to keep your St eam Ge nerat or in the bes t o perating condi t i o n at all t imes.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 7 o f 33 3.2) CLEANING WATER LEVEL PR OBES (Continue d) 6. C lean pro bes to rem o v e rust and scaling. NOTE: To cl ean pro b es y ou m a y use wi r e whee l, wi re brush, st ea l wo o l , or Scot ch - Bri te.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 8 o f 33 3.4) REPLACING GLASS GAUGE & RUBBE R WASHERS O R GLASS PACKINGS The S ight G lass (#10) g ives t he operato r the abili t y t o eas i ly m o ni to r the actual water level inside the chamber.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 9 o f 33 3.4) REPLACING GLASS GAUGE & RUBBE R WASHERS O R GLASS PACKINGS (Continued) The Sight Gl ass (#10) gi ves the op erato r the abili t y t o eas ily m o ni to r the actual wat er l evel ins ide t he chamber.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 10 o f 33 3.5) CHAMBER CHEMICAL/ACID TREATME N T All E lectr i c Steam Generato r sh oul d be cleaned re gu l arly. Th e fo ll o w ing is t he l east am ount o f t imes reco mmended to clean out y our chamber: NORM AL WATER AREAS – Sho uld be done ONCE A YEAR .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 11 o f 33 3.5) CHAMBER CHEMICAL/ACID TREATME NT (Continue d) 4. C l o se Manu al Dr ain (#19) and St eam Out (#1 6) ; tur n generator o n un t i l Sight G lass (#10) shows that it i s 1/2 full, and t h en shut o ff .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 12 o f 33 3.6) PRESSURE CONTROL DA T A SH EET DEFINI TIONS: “CONTROL” PRESSURE CONTROL – This pressure cont ro l s ho u l d be t he o nly one contro lling t he operatin g pressure o f the gen erat or .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 13 o f 33 3.7) SETTING THE PRESSURE CONTROLS SETTING PRESSURE CONTROLS INSTUCTIONS: WARNING – T he pressure co nt ro l s m ust b e set while all circu i t s are live.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 14 o f 33 3.7) SETTING THE PRESSURE CONTROLS (Continue d) 5. At t his po int the cont acto r ( s) shou ld b e click ed o ff and y ou s ho ul d be able to cl ick them on and then off again by pre ss ing t he SAFETY RESET .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 15 o f 33 4.) CALCULATIONS AND DATA S H EETS 4.1) HEATER POWER & VOLT AG E RATINGS LG Model uni t s use 3 H eat er s t o m eet t h e requi re d (K W) POWER f r o m the custo mer’s specified INPUT VOLTAGE .
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 16 o f 33 4.3) AMPERAG E CALCULATIONS The INPUT VOLTAGE, PHASE, TOTAL PO WER RATING, and HEAT ER VOLTAGE RATING are used to cal culate t he am perage . NOTE: 380- 425V heat ers ar e not usually rat ed for 380 - 425V.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 17 o f 33 4.4) ACTUAL POWER RATING CAL CULATIONS Because t he HEATE R VOLTAGE RATINGS only co me in 4 different vol t ages, and there .
LOW PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 06-19-07 CHRISTOPHER FERRARA DECRIPTIONS: 06-19-07 06-19-07 06-19-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: - - LG 10-30 (PARTS LEGEND) LG (L) 321-010-030-000100 This drawing and all information therein are the property of Electro-Steam Generator Corp.
LOW PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 06-19-07 CHRISTOPHER FERRARA DECRIPTIONS: 06-19-07 06-19-07 06-19-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: .
HIGH PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 06-19-07 CHRISTOPHER FERRARA DECRIPTIONS: 06-19-07 06-19-07 06-19-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: - - LG 10-30 (PARTS LEGEND) LG (H) 321-010-030-000200 This drawing and all information therein are the property of Electro-Steam Generator Corp.
HIGH PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: SCALE: N/A SHEET: 1 OF 1 DRAWN BY: 06-19-07 CHRISTOPHER FERRARA DECRIPTIONS: 06-19-07 06-19-07 06-19-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHE.
22 of 33 CLEARANCE TO SERVICE WATER LEVEL PROBES CLEARANCE FOR HEATER SERVICE INSTALLATION DATA LG (L) This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed, in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.
INSTALLATION DATA LG (L)(MAFD) CLEARANCE FOR HEATER SERVICE CLEARANCE TO SERVICE WATER LEVEL PROBES This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed, in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.
CONTROL SAFETY SAFETY CONTROL CLEARANCE HOLES FOR ELECTRIC SERVICE 2.75" DEPTH This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed, in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.
HIGH PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 07-16-07 - DECRIPTIONS: 07-16-07 - 07-16-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: MOTORIZED AUTO-FLUSH &am.
LOW PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 09-12-07 CHRISTOPHER FERRARA DECRIPTIONS: 09-12-07 09-12-07 09-12-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: - - LG 10-30 LG (L) 121-010-030-111100 This drawing and all information therein are the property of Electro-Steam Generator Corp.
LOW PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 09-12-07 CHRISTOPHER FERRARA DECRIPTIONS: 09-12-07 09-12-07 09-12-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: .
HIGH PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: DRAWN BY: 09-12-07 CHRISTOPHER FERRARA DECRIPTIONS: 09-12-07 09-12-07 09-12-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHECKED: ENGINEER: APPROVED: - - LG 10-30 LG (H) 121-010-030-111200 This drawing and all information therein are the property of Electro-Steam Generator Corp.
HIGH PRESSURE DRAWING TITLE: MODEL UNIT: DWG NO.: SCALE: N/A SHEET: 1 OF 1 DRAWN BY: 09-12-07 CHRISTOPHER FERRARA DECRIPTIONS: 09-12-07 09-12-07 09-12-07 SAL NEGRO CHRISTOPHER FERRARA JOHN PARDINI CHE.
T1 T2 T3 L2 L1 L3 T1 T2 T3 L3 L1 L2 30 of 33 This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed, in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.
L1 L3 L2 L3 T3 T2 T1 T3 L2 L1 T2 T1 L3 L2 L1 T3 T2 T1 L3 L2 L1 T3 T2 T1 (1PH) 25-30KW (208-240V) (1PH) 15-20KW (208-240V) (1PH) 30-40KW (440-480V) T2 T1 L1 L2 T3 L3 This drawing and all information therein are the property of Electro-Steam Generator Corp.
(1PH) 10-30KW (550-600V) LG 10-30 (1PH) 10KW - (550-600V) (1) 13067 - 50AMP CONTACTOR (1) 13059A - 30AMP 600V CLS-R FUSE BLOCK (2) 13010A - 20AMP 600V CLS-RK5 FUSES (3) 10006 - 3.33KW 600V HEATERS (1PH) 20KW - (550-600V) (1) 13069 - 75AMP CONTACTOR (1) 13056A - 60AMP 600V CLS-R FUSE BLOCK (2) 13013A - 40AMP 600V CLS-RK5 FUSES (3) 10050 - 6.
LG-10 thru LG -30 - User Manual Electro -Steam Generat or Co rp . 33 o f 33 Electro - Steam Generator Corporation T erm s and Conditions of Sale Thes e terms and co nditi o ns apply t o all g o ods or ser vices Seller provides .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté LG Electronics 30 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du LG Electronics 30 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation LG Electronics 30, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le LG Electronics 30 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le LG Electronics 30, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du LG Electronics 30.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le LG Electronics 30. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei LG Electronics 30 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.