Manuel d'utilisation / d'entretien du produit RAVL30 du fabricant Lennox Hearth
Aller à la page of 44
P/N 775230M Rev . D 08/2011 Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 775230CF . MODELS This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
2 S af e ty an d Y o u r F i r e p l a c e T o prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.
3 Afin d'éviter de vous brûler gravement ou de vous blesser , installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. P o ur c om m a n de r un P A N N EA U DE P RO T E C TI ON L e nn ox ® G RA T UI T p o ur v ot r e f oy er , c on su lt e z l e s dé t a i ls d a n s la p a r t ie g a u ch e.
4 Important Safety Information 1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. 2. Do not use this appliance if any part has been under water . Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water .
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure A Figure B A PP OS I TI ON DE S M IS E S EN GA R DE R E LA T IV E S À L A S ÉC UR I TÉ D’ UT I LI SA T I ON V ot r e fo ye r a ét .
6 W arranty Information Your gas appl iance is covere d by a limited lifetime warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other documents for future reference.
7 General Information Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE FO R YOUR SAF ETY do no t inst all or op er - ate this appliance without first reading and understanding this manual.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Installation of these appliances are approved for installation in New Y ork City in the US state of New Y ork (MEA#: 138-07 -E).
9 PRE-INST ALLA TION Features Installation Options .25 Residential .25 Vented vertical and horizontal .25 Manufactured (mobile) home .25 Natural gas (NG) or propane (LP) .25 Bedrooms .25 Optional wall-mounted thermostat Venting This fireplace can be vented using Secure Vent™ direct-vent pipe by Security Chimneys™*.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. u The center of the access hole for the gas piping is located at the left side of the fireplace 6-1/4” back from the front edge and 2-1/8” up from the base of the unit. v The electrical access is located at the right lower rear of the fire- place.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Framing Dimensions The dimensions given on this page are minimum framing distances necessary to maintain safe clearances between the Ravelle™ 30 gas fireplace and combustible materials.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 40.59 1.39 20.94 21.97 28.05 14.05 40.95 5.01 11.45 40.59 3.92 20.38 9.63 3.57 5.45 7.90 22” (558mm) 40-9/16” (1 0 31 mm ) 5” (127mm) 14-.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Raised Installations The fireplace may be raised by building a platform of sufficient strength to support the fireplace and pipe.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. The screws should be driven through the cement board into the outer metal skin of the fireplace.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Facing Greater Than 1” (25mm) Thick: If the combined thickness of the facing material (eg. brick or cultured stone) and cement board is greater than 1”, then the facing material must be placed around the face.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 2. Bracket C in the lower diagram is installed on the face during the face assembly (see instructions included with face). The captive screws D on this bracket should be screwed into captive nuts E on the fireplace.
17 Application: The Ravelle™ 30 gas fireplace, has been tested and listed as a direct- vent heater system by OMNI-T est Laboratories, Portland, Oregon and is recommended for use with Secure Vent™ direct-vent pipe by Security Chimneys™. IMPORT ANT : • Read all instructions carefully before starting the installation.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 15 Vent Considerations T wist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slid.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Horizontal Vent Installation IMPORT ANT NOTES: 1. All Ravelle™ 30 gas fireplaces that are horizontally terminated may only use 6-5/8” x 4” direct-vent pipe by Security Chimneys™ or Dura-Vent ® .
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. IMPORT ANT NOTES: 1. All Rav elle™ 30 fireplace vertically terminated may only use 6-5/8” x 4” Secure Vent™ direct-vent pipe by Security Chimneys™ or GS direct-vent pipe by Dura-Vent ® .
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flue Restrictors The flue restrictor settings shown in Figures 20 and 21 are for typical installations and may need to be adjusted from standard to take into accou nt other vari ables in the ins tallatio n to achieve pro per combust ion.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Vertical T erminations The diagram to the below shows all allowable combinations of straight vertical and offset to ver tical vent configurations with vertic al terminations . The termination must fall within the shaded areas on the diagram.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Exterior Horizontal Vent T ermination Clearance Requirements V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C K X * S ee It em D in th e T e x t B e lo w .
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 24 Figure 25 Figure 26 Log Installation Instructions If logs are not installed according to the log installation instructions, flame im.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. * The breaker supplying electricity to the fireplace must be turned off at the electrical panel before any connections are made at the fireplace. * The wire supplying the fireplace should be a minimum of 14 gage and provide 120 Volts at 60 hz.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fuel T ype Inlet Pressure Manifold Pressure Desired Minimum Maximum On Hi Fire On Lo Fire Natural Gas 7" WC 5" WC 10.5" WC 3.5" WC 1.7" WC LP Gas 11" WC 1 0.5 " W C 13" WC 10" WC 5.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A number of different options are available to the homeowner to maximize the heat output and air movement to different rooms in the house.
28 INST ALLER INSTRUCTIONS - A TT ACHING SAFETY -IN-OPERA TION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
29 Operating Instructions Pre-Lighting Checklist Be sure to chec k the se items bef ore the init ial ligh ting of the firep lace : c The fireplace gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10. Aft er pil ot is lit , t urn ga s c ont rol k nob co unt er clo ckw ise .2 to "ON." Knob can only be turned to "ON" if the knob has popped out.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flame Color and Behavior Y our Ravelle™ 30 gas fireplace is designed for maximum heating ef- ficiency . Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish.
32 Blower Operation Y our Ravelle 30 gas fireplace comes equipped with a 155 CFM blower with a variable speed control and an automatic temperature activated on/off snap switch. Operation: 1. After the fireplace warms up, a heat activated switch will turn on the blower .
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Options Y our Ravelle™ 30 gas fireplace comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round rocker switch located behind the lower door of the fireplace’ s face.
34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Vent Pipe Maintenance Conduct an inspection of the venting system semi-annually . Recom- mended areas to inspect are as follows: 1. Check areas of the venting system which are exposed to the elements for corrosion.
35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Glass/Door Maintenance Cleaning: When cool, the glass may be cleaned with a clean, soft cloth and a household glass cleaner . For cleaning white condensation from the interior glass use a gas fireplace glass cleaner available from your fireplace dealer .
36 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Log Set Installation on Page 24 .
37 W ARNING Fa i lu re to p os it io n the p ar ts in a cc or da nc e wi th th e se di a gr am s or fa il ur e to us e on ly pa rt s sp ec ifi ca ll y ap p ro ve d wi th th is a pp li an ce ma y re su l t in p ro pe rt y da m ag e or p er s on al i nj ur y .
38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Br ic k P an el K it s (ref. form #775268M) Ca t. N o . Mo de l De sc ri pt io n H7982 RA VL30-STD-BRK Standard T an Brick 75360 RAVL30-RED-BRK Red Brick Mi sc . 75259 NP-RA VL30/42 Nail Plates (4x12) galvanized Re mo te Th er mo st at i s no t co mp at ib le w it h R3 0.
39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Ar ch F a ce - Re qu ir e d to Co mp le t e Fa ce : In se ts (ref. form #775253M) 75 28 6 AI F3 0- BL K Bl ac k Fa ce, 3 5- 1/ 2” W x 24 -7 /.
40 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. RA TINGS NG LP NG LP Input Rate on “HI” (BTU/H) 30,000 28,500 Minimum Inlet Pressure (in. WC) 5 11 Input Rate on “LO” (BTU/H) 20,000 20,000 Manifold Pressure on “HI” (in. WC) 3.5 1 1 Orifice Size (DMS)* #37 #51 Manifold Pressure on “LO” (in.
41 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FOR YOUR SAFETY READ BEFORE LIGHTING WAR NING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by a piezo igniter .
42 REMARQUE : LES SCHÉMAS ET LES ILLUSTRA TIONS NE SONT PAS À L ’ÉCHELLE LIGHTING LABEL - FRENCH POUR PLUS DE SÉCURITÉ, LIRE A V ANT D’ALLUMER INSTRUCTIONS D’ALLUMAGE COMMENT COUPER L ’ADMISSION DE GAZ DE L ’APP AREIL 4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le .
43 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTES.
44 Y our Fireplace’ s Model Number ________________________________________ Y our Fireplace’ s Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installe.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lennox Hearth RAVL30 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lennox Hearth RAVL30 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lennox Hearth RAVL30, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lennox Hearth RAVL30 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lennox Hearth RAVL30, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lennox Hearth RAVL30.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lennox Hearth RAVL30. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lennox Hearth RAVL30 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.