Manuel d'utilisation / d'entretien du produit LMBV-42REN du fabricant Lennox Hearth
Aller à la page of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS 42" B-VENTED GAS APPLIANCES P/N 850,041M REV. A 02/2007 Millivolt Models Electronic Models LMBV-42RMN LMBV -42REN LMBV-42RMP FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Massachusetts and New York Requirements ...............................
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CLEARANCES Minimum clearance to combustibles for the ap- pliance is as follows: sides and back - 0" (0 mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm), ceiling - 64" (1625 mm). Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Framing Dimensions Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. All appliances are equipped with a gas flex line and shutoff valve attached directly to the gas control valve.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 11 Step 5. Field Wiring – Refer to Section A for millivolt appliances and Section B for electronic appliances. A. Millivolt Wiring – The gas valve has been set in place and has been pre-wired at the factory.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 14 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Replace logs if removed for pilot inspection. To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position (“ON” will be to the left hand side of the valve).
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob/lever in “ON” position and turn the remote switch “OFF.” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Fireplace Opening Spacer Finished Wall Header 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 12 Combustible Mantel Clearances Inches Min. Height of Mantel Above Fireplace Opening Max.Length of Mantels Three mantels are shown (dark gray elongated rectangles)- one, 1 ¹⁄₂ in.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Gas Conversion Kits In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 5. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2006 by Lennox Hearth Products P/N 850,041M REV. A 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lennox Hearth LMBV-42REN c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lennox Hearth LMBV-42REN - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lennox Hearth LMBV-42REN, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lennox Hearth LMBV-42REN va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lennox Hearth LMBV-42REN, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lennox Hearth LMBV-42REN.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lennox Hearth LMBV-42REN. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lennox Hearth LMBV-42REN ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.