IMPORTANT SAFETY INSTRUCTIONS

I Never leave the surface units unattended at high settings.

I Use this unit only in the manner intended by the

Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

manufacturer. If you have questions, contact the manufacturer.

I Always turn hood ON when cooking at high heat or when

flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

I Before servicing or cleaning the unit, switch the power off at

the service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

I Clean ventilating fans frequently. Grease should not be

allowed to accumulate on fan or filter.

I Use proper pan size. Always use cookware appropriate for

the size of the surface element. WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a

I Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction.

I Sufficient air is needed for proper combustion and

I SMOTHER FLAMES with a close fitting lid, cookie sheet, or

exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

other metal tray, then turn off the gas burner or electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

I NEVER PICK UP A FLAMING PAN - you may be burned.

I DO NOT USE WATER, including wet dishcloths or towels -

a violent steam explosion will result.

I When cutting or drilling into wall or ceiling; do not damage

electrical wiring and other utilities.

I Use an extinguisher ONLY if:

I Ducted systems must always be vented outdoors.

– You know you have a class ABC extinguisher, and you

already know how to operate it.

to exhaust hazardous or explosive materials and vapors.

– The fire is small and contained in the area where it

started.

air, be sure to duct air outside - do not vent exhaust air into spaces within walls ceilings, attics, crawl spaces, or garages. WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

– The fire department is being called.

– You can fight the fire with your back to an exit.

aBased on "Kitchen Fire Safety Tips" published by NFPA.

I WARNINGTo reduce the risk of fire or electrical shock,

do not use this fan with any solid-state speed control device.

SAVE THESE INSTRUCTIONS

INSTALLATION REQUIREMENTS

Tools and Parts Gather the required tools and parts before starting installation. Read and follow the safety instructions provided with any tools listed here. Tools needed

Parts supplied Check that all parts are included.

I 1¹⁄₄" drill bit

I Hardware package (4 screws)

Parts needed UL listed or CSA approved ¹⁄₂" (12.5 mm) strain reliefs (2) Power supply cable 6" (15.2 cm) round wall or roof cap 6" (15.2 cm) metal vent system

I Wire stripper or utility knife

I Tape measure or ruler

I Caulking gun and weatherproof caulking compound

I Saber or keyhole saw

Show 9 more labels / short text on this page
I Duct tape · I Flat-blade screwdriver · I Metal snips · I Level · I Phillips screwdriver · I Drill · I Literature package · I Pencil · I Pliers
Page 4 of the KitchenAid 2005 user manual — Venting Requirements
Page 4 · cliquer pour agrandir
Page 4

Installation Clearances

Location Requirements IMPORTANT: Observe all governing codes and ordinances.

I It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the rear wall.

I Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width

I Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult your cooktop/range manufacturer installation instructions before making any cutouts.

24" (61 cm) min. 30" (76.2 cm) suggested max. bottom of hood to

I Grounded electrical outlet is required. See “Electrical Requirements” section.

70 ⁵⁄₁₆" (178.6 cm)

I The hood is factory set for vented installations. For recirculating installations, Recirculation Kit Part Number 4396565, including vent cover and 2 charcoal filters, is available from your dealer.

13" (33 cm) cabinet depth

min. 76 ⁵⁄₁₆" (193.8 cm)

18" (45.7 cm) min. clearance

max. to bottom of cabinet frame

I All openings in ceiling and wall where range hood will be installed must be sealed.

Product Dimensions

5 ⁷⁄₈" (14.9 cm) diam. exhaust collar

36" (91.4 cm) base cabinet

14 ⁷⁄₈" (37.8 cm)

8 ¹⁄₁₆" (20.5 cm)

1³⁄₈" (3.5 cm)

10 ⁵⁄₁₆" (26.2 cm)

29 ⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model 35 ⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model

19 ¹⁄₂" (49.5 cm)

Venting Requirements

I Do not terminate the vent system in an attic or other enclosed area.

Vent and electrical openings and mounting screw locations

KitchenAid 2005 — Venting Requirements diagram (page 4)
Fig. 1 · Venting Requirements

I Do not use a 4" (10.2 cm) laundry-type wall caps.

I Vent system must terminate to the outside.

I Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is recommended. Do not use plastic or metal foil vent.

I The size of the vent should be uniform.

I The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.

I Use duct tape to seal all joints in the vent system.

I Use caulking to seal exterior wall or roof opening around the cap.

I Determine which venting method is best for your application.

13 ¹⁄₂" (34.3 cm) - 30" (76.2 cm) model 16 ¹⁄₂" (41.9 cm) - 36" (91.4 cm) model

Show 6 more labels / short text on this page
cooking surface · upper cabinet · to countertop · centerline · of hood · height
Page 5 of the KitchenAid 2005 user manual — Calculating Vent System Length
Page 5 · cliquer pour agrandir
Page 5

For Best Performance:

Example vent system

I Do not install 2 elbows together.

I Use no more than three 90° elbows.

6 ft (1.8 m)

I If an elbow is used, install it as far away as possible from the hood’s vent motor exhaust opening.

I Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than one elbow is used.

2 ft (0.6 m)

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance. Cold Weather Installations An additional backdraft damper should be installed to minimize backward cold air flow and a nonmetallic thermal installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems with greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Maximum length = 35 ft (10.7 m)

1- 90° elbow = 5 ft (1.5 m)

8 ft (2.4 m) straight = 8 ft (2.4 m)

1. wall cap = 0 ft (0 m)

System length = 13 ft (3.9 m)

Venting Methods

Electrical Requirements IMPORTANT: Observe all governing codes and ordinances. Save Installation Instructions for electrical inspector’s use. It is the customer’s responsibility to contact a qualified electrical installer, and to assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A copy of the above code standards can be obtained from:

This range hood is factory set for vented installations. Vent system can terminate through either the roof or wall. A 6" (15.2 cm) round vent system must be used. The vent system length should not exceed 35 ft (10.7 m).

Option 1 - Roof Venting Option 2 - Wall Venting

B

B

National Fire Protection Association

CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575

I A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is required.

A. 6" (15.2 cm) round roof

A. 6" (15.2 cm) round wall

venting B. Roof cap

venting B. Wall cap

I Do not ground to a gas pipe.

I Check with a qualified electrician if you are not sure range hood is properly grounded.

Calculating Vent System Length

I Do not have a fuse in the neutral or ground circuit.

I The range hood must be connected with copper wire only.

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

I The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable.

Vent piece 6" (15.2 cm) round

45° elbow 2.5 ft (0.8 m)

I Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specified on the model/ serial rating plate.

I Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

90° elbow 5.0 ft (1.5 m)

I A ¹⁄₂" (12.7 mm) UL listed or CSA approved strain relief must be provided at each end of the power supply cable (at the range hood and at the junction box).

Show 4 more labels / short text on this page
wall cap · 90˚ elbow · One Batterymarch Park · Quincy, MA 02269
Page 6 of the KitchenAid 2005 user manual — Preparation
Page 6 · cliquer pour agrandir
Page 6

INSTALLATION INSTRUCTIONS

Venting Options

Venting through cabinet top

1. Mark the location where vent cover will be installed in the cabinet top and cut a 6" (15.2 cm) round vent opening for the vent cover.

General venting installation

For vented installations: Make necessary cuts in the wall for vent fittings. IMPORTANT: Make sure the vent system is installed before installing range hood. Rrecirculating installations: A vent system (not provided) that directs the recirculated air back into the room either through the soffit or through the cabinet top is required. Use Recirculation Kit Part Number 4396565. For ordering information, see “Assistance or Service.” IMPORTANT: If venting through the cabinet top, do not terminate the exhaust into dead air space such as an attic or enclosed soffit. When venting through the soffit, assemble the vent system you will use over the exhaust collar, but do not attach the vent system yet. NOTE: The vent system can exhaust out the front of the soffit or be rotated to exhaust out the side or end of the soffit.

B C

D

E

A. Vent system B. Vent cover C. Cabinet top

D. Ceiling or soffit

E. Hood

Venting through the soffit

Prepare Location

1. Assemble the vent system you will use over the exhaust collar, but do not attach the vent system yet. NOTE: The vent system can exhaust out the front of the soffit or be rotated to exhaust out the side or end of the soffit.

I For vented installations, it is recommended that the vent system be installed before hood is installed.

I Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

2. Measure distance “A” (from top of hood to centerline of 6" [15.2 cm] round vent). Mark the distance “A” on soffit.

I Before making cutouts, make sure there is proper clearance within the ceiling or wall for vent fittings.

I Check that all the installation parts and the box with filters have been removed from the shipping carton.

Preparation

3. Mark and cut a 6" (15.2 cm) round vent opening.

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

1. If possible, disconnect power and/or gas supply and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall.

Excessive Weight Hazard

Page 7 of the KitchenAid 2005 user manual — Install Range Hood
Page 7 · cliquer pour agrandir
Page 7
2. Select a flat surface for assembling the hood. Cover that surface with a protective covering such as a blanket or cardboard during assembly.
8. Cut a 1 ¹⁄₄ " (3.2 cm) hole for power supply cable.

upper cabinet or soffit mounting surface

8 ¹⁄₁₆" (20.5 cm)

1³⁄₈" (3.5 cm)

Use two or more people to move and install range hood.

power supply cable hole in wall

Failure to do so can result in back or other injury.

9. Run wire through hole in accordance with the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the connection in the range hood’s electrical box. 10. Use caulking to seal all openings. IMPORTANT: Do not turn on power until installation is complete.
3. Using 2 or more people, slowly lift the range hood onto the protected surface. 4. Tip range hood on its back to remove the metal filters. Turn knob to the left (counterclockwise) and lift filters out.

Install Range Hood

5. Remove hardware package. 6. Add wood filler strips as needed to cabinet bottom. Drill 4 ³⁄₁₆ " (4.8 mm) clearance holes for hood mounting screws.

Use two or more people to move and install range hood.

13 ¹⁄₂" (34.3 cm) - 30" (76.2 cm) model 16 ¹⁄₂" (41.9 cm) - 36" (91.4 cm) model

Failure to do so can result in back or other injury.

1. Remove the terminal box cover (located on back wall of hood) from the hood. Remove the power supply cable knockout using a flat-blade screwdriver. Attach strain relief in power supply cable opening so that clamping screws are inside of range hood. Tip hood back to its bottom surface.

10 ⁹⁄₁₆" (26.8 cm)

2. If roof or wall cap does not have a damper, attach damper to exhaust opening on top of the range hood using 2 small screws from hardware package. 3. Place the range hood mounting screws close to the holes in the cabinet bottom. 4. Lift range hood into place while feeding wiring through strain relief. 5. Insert the screws through the clearance holes and start them into the hood. Then, tighten screws securely. 6. Connect vent system, for either vented or recirculating, to range hood. 7. Seal all joints with duct tape. 8. For recirculating installations, install the vent cover included in Recirculation Kit Part Number 4396565 in soffit or cabinet top vent opening.

⁷⁄₈" (2.2 cm) ³⁄₁₆" (94.8 mm) clearance holes wall wood filler strips (recessed cabinet

7. Cut a 6 ¹⁄₂ " (16.5 cm) diameter hole in cabinet bottom as shown.

6 ¹⁄₂" (16.5 cm) diam. hole centerline

wall 4" (10.2 cm)

Show 5 more labels / short text on this page
Excessive Weight Hazard · centerline · Excessive Weight Hazard · centerline · bottoms only)
Page 8 of the KitchenAid 2005 user manual — B
Page 8 · cliquer pour agrandir
Page 8

Make Electrical Connection

Install Filters 1. For recirculating installations only, install the charcoal filters included in Recirculation Kit Part Number 4396565. Place the charcoal filter against the blower cover and rotate to the right (clockwise) to attach to cover. Repeat with other charcoal filter.

KitchenAid 2005 — Make Electrical Connection diagram (page 8)
Fig. 2 · Make Electrical Connection

Failure to do so can result in death or electrical shock.

A. Filter

2. Replace metal filter. Turn knob on metal filter to the right (clockwise) to attached to range hood.
1. Disconnect power at the circuit breaker of fused circuit box. 2. Connect the white wire of the power supply cable with the white lead in the range hood using a twist-on connector. 3. Connect the black wire of the power supply cable with the black lead in the range hood using a twist-on connector.
KitchenAid 2005 — Make Electrical Connection diagram (page 8)
Fig. 3 · Make Electrical Connection
KitchenAid 2005 — Make Electrical Connection diagram (page 8)
Fig. 4 · Make Electrical Connection

Check Operation 1. Check operation of the range hood by turning on the power. 2. The range hood controls are located on the right-hand underside of the range hood.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death or electrical shock.

4. Connect the green power supply ground wire to the unused, green ground screw.

B

KitchenAid 2005 — B diagram (page 8)
Fig. 5

A. Controls B. Filters

3. Move the light switch to “1” position. The light should turn on. 4. Move blower switch to “1” position. The blower should operate. 5. Move the blower speed switch to “1” position for low speed, “2” position for medium speed or “3” position for high speed. 6. Move blower and light switches to “0” position to turn blower and light off. 7. If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power supply and check that the wiring is correct. NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.

A. Green ground screw B. Hood wiring C. White wires D. Twist-on connectors

E. Black wires F. Power supply cable

5. Tighten strain relief screws. 6. Replace the terminal box cover.
Page 9 of the KitchenAid 2005 user manual — Adjusting the blower
Page 9 · cliquer pour agrandir
Page 9

RANGE HOOD USE

RANGE HOOD CARE

The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the right-hand underside of the range hood.

Range Hood Lamps

Replacing a Halogen Lamp This hood uses four 12-volt, 20-watt halogen lamps. Turn off the range hood and allow the hallogen lamps to cool. Replace bulb using a tissue to handle bulb, or wearing cotton gloves. Do not touch bulb with bare fingers.

To Replace: 1. Disconnect power. 2. Remove 2 screws from the circular metal trim around the lamp assembly. 3. Pull the trim and lamp assembly down far enough so that the lamp can be pulled out of the socket clips.

A A

B

B C D

A. Remove 2 screws B. Pull trim with lamp assembly down

A. Controls B. Light switch C. Blower switch D. Blower speed switch

4. Insert the new lamp into the socket clips and push the lamp assembly back up into the hood. 5. Replace the screws. 6. Reconnect the power.

Range Hood Controls

Operating the light

Cleaning

1. Move the light switch to the “1” position to turn range hood light ON. 2. Move the light switch to the “0” position to turn range hood light OFF.

Exterior surfaces: Do not use steel wool or soap-filled scouring pads. Rub in direction of the grain line to avoid scratching the surface. Always wipe dry to avoid water marks.

I Stainless Steel Cleaner & Polish.

Operating the blower

I Mild liquid detergent and water.

1. Move the blower switch to the “1” position to turn the blower ON. The blower will begin operating at the speed set on the blower speed switch. 2. Move the blower switch to the “0” position to turn the blower OFF.

I Wipe with damp soft cloth or nonabrasive sponge, then rinse with clean water and wipe dry.

Metal Filters: For vented installations, use 2 hands to remove filters. Turn the knob to the left (counterclockwise) to release filter. Repeat with other filter.

Adjusting the blower

The blower has 3 speed controls. Move the blower speed switch to “1” position for low speed, “2” position for medium speed or “3” position for high speed.

Wash metal filters as needed in dishwasher or hot detergent solution to clean.

Page 10 of the KitchenAid 2005 user manual — ASSISTANCE OR SERVICE
Page 10 · cliquer pour agrandir
Page 10

Reinstall the filter by placing the back edge in the channel at rear of hood. Push filter into place, turn the knob to the right (clockwise) to attach to range hood. Repeat with other filter.

Remove the old charcoal filter: 1. Rotate to the left (counterclockwise) and pull away from the blower cover and discard filter pack. Repeat for other filter.

A. Filter

Recirculating Installation Filters: For recirculating installations, wash metal filters as needed in dishwasher or hot detergent solution to clean. Do not wash charcoal filter packs. Replace with Recirculation Kit Number 4396565.

2. Place the charcoal filter against the blower cover and rotate to the right (clockwise) to attach to cover. 3. Reinstall metal filter by placing back edge in channel at rear of range hood. Push filter up into place, turn the knob to the right (clockwise) to attach to range hood. Repeat with other filter.

Accessories Optional installation kits are available from your dealer. Recirculation Kit Part Number 4396565 includes 2 charcoal filter packs and vent cover.

ASSISTANCE OR SERVICE

Before calling for assistance or service, please check “Troubleshooting.” It may save you the cost of a service call. If you still need help, follow the instructions below. When calling, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request.

For further assistance If you need further assistance, you can write to KitchenAid with any questions or concerns at:

KitchenAid Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor, MI 49022-2692

If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new KITCHENAID® appliance. To locate factory specified parts in your area, call our Customer eXperience Center telephone number or your nearest designated service center.

Please include a daytime phone number in your correspondence.

In Canada Call the KitchenAid Canada Customer Interaction Centre toll free: 1-800-807-6777. Our consultants provide assistance with:

I Features and specifications on our full line of appliances.

In the U.S.A. Call the KitchenAid Customer eXperience Center toll free: 1-800-422-1230. Our consultants provide assistance with:

I Use and maintenance procedures.

I Accessory and repair parts sales.

I Referrals to local dealers, repair parts distributors, and service companies. KitchenAid Canada designated service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in Canada.

I Features and specifications on our full line of appliances.

I Installation information.

I Use and maintenance procedures.

For further assistance If you need further assistance, you can write to KitchenAid Canada with any questions or concerns at:

I Accessory and repair parts sales.

I Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.).

Customer Interaction Centre KitchenAid Canada 1901 Minnesota Court Mississauga, Ontario L5N 3A7

I Referrals to local dealers, repair parts distributors, and service companies. KitchenAid designated service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States.

Please include a daytime phone number in your correspondence.

To locate the KitchenAid designated service company in your area, you can also look in your telephone directory Yellow Pages.

Page 11 of the KitchenAid 2005 user manual — KITCHENAID ® VENTILATION WARRANTY
Page 11 · cliquer pour agrandir
Page 11

KITCHENAID ® VENTILATION WARRANTY

ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter “KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company.

ITEMS KITCHENAID WILL NOT PAY FOR 1. Service calls to correct the installation of your major appliance, to instruct you how to use your major appliance, to replace or repair house fuses or to correct house wiring or plumbing. 2. Service calls to repair or replace appliance light bulbs, air filters or water filters. Those consumable parts are excluded from warranty coverage. 3. Repairs when your major appliance is used for other than normal, single-family household use. 4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with electrical or plumbing codes, or use of products not approved by KitchenAid. 5. Replacement parts or repair labor costs for units operated outside the United States or Canada. 6. Pickup and delivery. This major appliance is designed to be repaired in the home. 7. Repairs to parts or systems resulting from unauthorized modifications made to the appliance. 8. Expenses for travel and transportation for product service in remote locations. 9. The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE. Outside the 50 United States and Canada, this warranty does not apply. Contact your authorized KitchenAid dealer to determine if another warranty applies. If you need service, first see the “Troubleshooting” section of the Use & Care Guide. After checking “Troubleshooting,” additional help can be found by checking the “Assistance or Service” section or by calling KitchenAid. In the U.S.A., call 1-800-422-1230. In Canada, call 1-800-807-6777. 9/05

Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in-warranty service. Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it. You will need to know your complete model number and serial number. You can find this information on the model and serial number label located on the product.

Show 6 more labels / short text on this page
Dealer name____________________________________________________ · Address ________________________________________________________ · Phone number__________________________________________________ · Model number __________________________________________________ · Serial number __________________________________________________ · Purchase date __________________________________________________
Page 12 of the KitchenAid 2005 user manual — WIRING DIAGRAM
Page 12 · cliquer pour agrandir
Page 12

WIRING DIAGRAM

KitchenAid 2005 — WIRING DIAGRAM diagram (page 12)
Fig. 6

Poser une question sur : KitchenAid 2005

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le KitchenAid 2005

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

KitchenAid 2005 manuel PDF

24 pages·553 KB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…