G&L SERIES SSH-C and SSH-F Installation, Operation and Maintenance Instructions


Goulds Pumps is a brand of ITT Water Technology, Inc. - a subsidiary of ITT Industries, Inc.
Engineered for life



3. Motors must be wired for proper voltage (check nameplate). Wire size must limit maximum voltage drop to 10% of nameplate voltage at motor terminals, or motor life and pump performance will be lowered. 4. Single-Phase: Thermal protection for single-phase units is sometimes built-in (Check nameplate). If no built-in protection is provided, use a contactor with proper overload. Fusing is permissible if properly fused. 5. Three-Phase: Provide three-leg protection with proper size magnetic starter and thermal overloads. 6. Maximum Liquid Temperatures: 212ºF (100ºC) with standard seal. 250ºF (120ºC) with optional high-temperature seal. 7. Maximum allowable operating pressure: 230 PSI (15 bars). 8. Maximum number of starts per hour: 20, evenly distributed. 9. Regular Inspection and Maintenance will increase service life. Base schedule on operating time.
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the fol- lowing signal words and be alert to the potential for personal injury or property damage. Warns of hazards that WILL cause serious personal injury, death or major property damage. Warns of hazards that CAN cause serious personal injury, death or major property damage.
Warns of hazards that CAN cause per- sonal injury or property damage. NOTICE: INDICATES SPECIAL INSTRUCTIONS WHICH ARE VERY IMPORTANT AND MUST BE FOLLOWED. THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP. MAINTAIN ALL SAFETY DECALS.
CAUTION
1. Close-coupled units may be installed inclined or vertical. Do not install with motor below pump. Condensation will build up in motor. 2. Locate pump as near liquid source as possible (below level of liquid for automatic operation). 3. Protect from freezing or floods. 4. Allow adequate space for servicing and ventilation. 5. For close-coupled pumps, the foundation must be flat and substantial to eliminate strain when tightening bolts. Use rubber mounts to minimize noise and vibration. Tighten motor hold-down bolts before connecting piping to pump. 6. For frame-mounted pumps, permanent and solid foundation is required for smooth operation. Bedplate must be grouted to a foundation with solid footing. 7. Place unit in position on wedges located at four points (Two below approximate center of driver and two below approximate center of pump). Adjust wedges to level unit, bringing coupling halves into reasonable alignment. Level or plumb suction and discharge flanges. 8. Make sure bedplate is not distorted and final coupling alignment can be made within the limits of movement of motor and by shimming if necessary. 9. Tighten foundation bolts finger tight and build dam around foundation. Pour grout under bedplate making sure the areas under pump and motor feet are filled solid. Allow grout to harden 48 hours before further tightening foundation bolts. 10. All piping must be supported independently of the pump, and must “line-up” naturally. Never draw piping into place by forcing the pump suction and discharge connections! 11. Angular alignment of the flanges can best be accom- plished using calipers at bolt locations (See illustra- tion).
UNIT NOT DESIGNED FOR USE WITH HAZARDOUS LIQUIDS OR FLAMMABLE GASES. THESE FLUIDS MAY BE PRESENT IN CONTAINMENT AREAS.
Hazardous fluids can cause fire, burns or death.
Always disconnect electrical power when handling pump or controls.
Hazardous voltage can shock, burn or cause death.

4.2. Do not use suction isolation valve to throttle pump! 5. Installation with pump above source of supply: 5.1. To avoid air pockets, no part of piping should be higher than pump suction connection. Slope piping upwards from liquid source. 5.2. All joints must be airtight. 5.3. Foot valve to be used only if necessary for prim- ing, or to hold prime on intermittent service. 5.4. Suction strainer open area must be at least triple the pipe area. 6. Size of inlet from liquid source, and minimum submer- gence over inlet, must be sufficient to prevent air entering pump.
6. Rotation
DO NOT PLACE HANDS IN PUMP WHILE CHECKING MOTOR ROTATION. TO DO SO WILL CAUSE SEVERE PERSONAL INJURY.
Always recheck both alignments after making adjustments. 6. Parallel misalignment exists when the shafts are not concentric. Place dial indicator on one hub and rotate this hub 360º while taking readings on the outside diameter of the other hub. Parallel alignment occurs when Total Indicator Reading is .005" or less. 7. Angular misalignment exists when the shafts are not parallel. Place dial indicator on one hub and rotate this hub 360º while taking readings on the face of the other hub. Angular alignment is achieved when Total Indicator Reading is .005" or less.
7. Operation
Pumped liquid provides lubrication. If pump is run dry, rotating parts will seize and mechanical seal will be damaged. 2. Make complete check after unit is run under operating conditions and temperature has stabilized. Check for expansion of piping. Check coupling alignment. 3. Do not operate at or near zero flow. Energy imparted to the liquid is converted into heat. Liquid may flash to vapor. Rotating parts require liquid to prevent scor- ing or seizing.
4. Suction Piping
Hazardous Machinery

10. Reassembly
FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE CAN CAUSE SHOCK, BURNS OR DEATH. 1. Bearings are located in and are part of the motor. For lubrication procedure, refer to manufacturer’s instruc- tions. 2. On frame-mounted units, regrease at 2,000 hours use or after 3 months. Use #2 Sodium or Lithium grease and fill until grease comes out of the relief fitting.
1. All parts should be cleaned before assembly. 2. Refer to parts list to identify required replacement items. 3. Reassembly is the reverse of the disassembly proce- dure. 4. Replace lip seals if worn or damaged (frame-mount only). 5. Replace ball bearings if loose, rough or noisy when rotated (frame-mount only). 6. Check shaft for maximum runout of .005" TIR. Bear- ing seats and lip seal areas must be smooth and free of scratches or grooves. Replace if necessary (frame- mount only). 7. All mechanical seal components must be in good condition or leakage may result. Replacement of complete seal assembly, whenever seal has been removed, is good standard practice. 8. If wear ring is being replaced, do not use lubricants on the metal-to-metal fit when pressing in the replace- ment. 9. If the impeller is removed, as for example to effect a mechanical seal change, this procedure must be followed: Old impeller bolt and impeller o-ring cannot be reused. 10. Install the mechanical seal stationary seat in the seal housing, using soapy water as a lubricant to ease insertion. 11. S-Group – Install the mechanical seal spring retainer, spring and rotary assembly on the shaft sleeve using soapy water to lubricate. Slide the shaft sleeve over the pump shaft, be sure that a new shaft sleeve o-ring is used. NOTE: The shaft sleeve o-ring and impel- ler washer o-ring are almost identical in diameter. be sure to use the square cross-section o-ring in the impeller washer. the round cross-section o-ring is used in the shaft sleeve. 11. M-Group – Install the mechanical seal spring and rotary on the shaft sleeve using soapy water to lubri- cate. Slide the shaft sleeve over the pump shaft. Be sure that a new shaft sleeve o-ring is used. Place the mechanical seal spring retainer over the impeller hub. 12. Place the impeller key into the shaft keyway and slide the impeller in place. Install the impeller stud and impeller washer. Be sure that a new impeller o-ring is used. Tighten S-Group (3⁄8" thread) to 17 lb.ft. and M-Group (½" thread) to 38 lb.ft. 13. Replace casing bolts and tighten in a crossing se- quence to the torque values indicated below. S-Group – 25 lb.-ft. (35 N-m) M-Group – 37 lb.-ft. (50 N-m) 14. Check reassembled unit for binding by rotating shaft with appropriate tool from motor end. 15. If rubbing exists, loosen casing bolts and proceed with tightening sequence again.
1. Always turn power off. 2. Drain system. Flush if necessary. 3. Remove motor hold-down bolts on close-coupled or disconnect coupling and remove spacer. 4. Remove casing bolts and pump hold-down bolts. 5. Remove motor and rotating element from casing. 6. Unscrew impeller bolt with a socket wrench. Do not insert screwdriver between impeller vanes to prevent rotation. It may be necessary to use a strap wrench around the impeller if impacting the socket wrench will not loosen the impeller bolt. 7. Remove impeller o-ring. 8. Insert two pry bars (180º apart) between impeller and seal housing. Pry off impeller. 9. Remove shaft sleeve, seal spring, cupwasher, seal rotary and impeller key. 10. Remove seal housing. 11. Place seal housing on flat surface. Press out stationary seal parts. 12. Remove deflector from shaft on frame-mounted units. 13. Remove bolts holding bearing cover to frame and remove bearing cover (frame-mount). 14. Remove lip seals from bearing frame and bearing cover (frame-mount). 15. Remove shaft and bearings from frame (frame- mount). 16. Remove bearing retaining ring (frame-mount). 17. Use bearing puller or arbor press to remove ball bearings (frame-mount). 18. Remove wear ring if excessively worn. Use pry bar and/or vicegrips.

1. Motor does not start, and no noise or vibration oc- curs: 1.1. Power supply not connected. 1.2. Fuses or protection device tripped or defective. 1.3. Loose or broken electrical connections. 2. Motor will not start, but generates noise and vibration: 2.1. Motor not wired as directed on diagram. 2.2. Shaft locked due to mechanical obstructions in motor or pump. 2.3. Low voltage or phase loss on three phase supply. 3. Pump does not deliver rated capacity: 3.1. Pump not filled and primed. 3.2. Pump has lost prime due to leaks in suction line. 3.3. Direction of rotation incorrect. See Rotation. 3.4. Head required is higher than that originally specified. (Valve may be partially closed.) 3.5. Foot valve clogged. 3.6. Suction lift too high. 3.7. Suction pipe diameter too small. 4. Protection trips as unit starts: 4.1. Phase loss on three-phase supply. 4.2. Protection device may be defective. 4.3. Loose or broken electrical connections. 4.4. Check motor resistance and insulation to ground. 5. Protection device trips too often: 5.1. Protection may be set to a value lower than motor full load. 5.2. Phase loss due to faulty contacts or supply cable. 5.3. Liquid is viscous or its specific gravity is too high. 5.4. Rubbing occurs between rotating and stationary parts.
6. Shaft spins with difficulty: 6.1. Check for obstructions in the motor or the pump. 6.2. Rubbing occurs between rotating and stationary parts. 6.3. Check bearings for proper conditions. 7. Pump vibrates, runs noisily, and flow rate is uneven: 7.1. Pump runs beyond rated capacity. 7.2. Pump or piping not properly secured. 7.3. Suction lift too high. 7.4. Suction pipe diameter too small. 7.5. Cavitation caused by insufficient liquid supply or excessive suction losses. 7.6. Impeller blockage. 8. When stopped, unit turns slowly in the reverse direc- tion: 8.1. Leaks on air locks in suction pipe. 8.2. Partial blockage in check valve. 9. In pressure boosting applications, the unit starts and stops too often: 9.1. Pressure switch settings are incorrect. 9.2. Tank size may be incorrect. 10. In pressure boosting applications, the unit does not stop: 10.1. Pressure switch maximum setting is higher than was specified. 10.2. Direction of rotation incorrect. See Rotation.

100 101 178 108 370

199 422 408 126 371
Optional Mechanical Seals
383A (S-GROUP LOCATION)

383 100 101 513 370 184 108 228

333A
103 199 422 408 178 370B 123 168 112 136
Optional Mechanical Seals
383A (S-GROUP LOCATION)

SSH S-Group – Engineering Data, Información Técnica, Données techniques – SSH, groupe S
Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End; Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor; Plaque de base profilée en U et rotation en sens horaire (vue de l’extrémité du moteur)
Y 3 5 ⁄ 8 CP 3¾
C MAX.
SPACER COUPLING ACOPLE DEL ESPACIADOR; ACCOUPL. À PIÈCE D’ÉCART.
AB MAX.
COUPLING GUARD, GUARDA ACOPLE; CARTER D’ACCOUPL. 1.125 1.124
Ø
(4) HOLES
SUCTION SUCCIÓN ASPIRATION
SINGLE PHASE ONLY, SOLO UNIFÁSICOS; MONOPHASÉ SEULEMENT
5⁄8 DIA.
P MAX.
5 ⁄ 8 DIA.;
4 TROUS, DIAM. : 5 ⁄ 8
DC MAX.
KEYWAY 1⁄8 x ¼ CHAVETERO 1⁄8 x ¼ LOGEMENT DE CLAVETTE, 1⁄8 x ¼
HG
DRAIN PLUG, TAPÓN DE DRENAJE BOUCHON DE VIDANGE
3⁄8" GAS THREAD; UNI ISO 228/1; 3⁄8, PAS DU GAZ (UNI ISO 228/1)
HP
HE HE HA
3⁄8 - 16 du corps de pompe à 12 lbf·pi. 2. Les dimensions sont en pouces, et le poids, en livres. 3. Les dimensions et le poids du moteur peuvent varier selon le fabricant. 4. Ne pas utiliser les dimensions pour la construc- tion si elles ne sont pas certifiées à cette effet.
Available Motor and Bedplate Dimensions and Weights, Pesos y Dimensiones Disponibles de la Fundación y del Motor Dimensions et poids – moteur et plaque de base
➀ For use with ANSI class 150 mating flanges. Para usar con bridas que casan ANSI clase 150. À utiliser avec des contre-brides ANSI, classe 150.
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs. “HP” Dimensions at motor end only. * “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required.
Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras. Dimensiones “HP” sólo en el extremo del motor. * La dimensión “HD” para el bastidor del motor 254T/256T de 1 x 2 - 10 es sólo 11"; se requieren una cuña del motor de ¾" y una cuña del bastidor de apoyo de 1¾".
ODP = carcasse abritée (à ouvertures de ventilation protégées) ; TEFC = carcasse fermée autoventilée. *Dimensions HP à l’extrémité du moteur seulement. La dimension HD pour la carcasse 254T ou 256T, version 1X2-10 seulement, est de 11 po ; une cale de moteur de ¾ po et une cale de palier de 1¾ po sont requises.
1,125 1,124

SSH S-Group Close Coupled – Dimensions and Weights, SSH Acople Cerrado – Dimensiones y Pesos, Dimensions et poids – SSH montée sur moteur, groupe S
(All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)

3⁄8" GAS THREAD UNI ISO 228/1 3⁄8, PAS DU GAZ (UNI ISO 228/1)
7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. Las dimensiones puede que varíen con los fabricantes. 4. No para propósitos de construcción.
NOTA : 1. L’orifice de refoulement est orienté vers le haut. Pour l’orienter autrement, enlever les vis de fixation du corps de pompe, placer l’orifice dans le sens voulu, puis reposer et serrer les vis 3⁄8 - 16 à 12 lbf·pi et 7⁄16 - 14 à 20 lbf·pi. 2. Les dimensions sont en pouces, et le poids, en livres. 3. Les dimensions et le poids du moteur peuvent varier selon le fabricant. 4. Ne pas utiliser les dimensions pour la construction si elles ne sont pas certifiées à cette effet.
➀ For use with ANSI class 150 mating flanges. Para usar con bridas que casan ANSI clase 150. À utiliser avec des contre-brides ANSI, classe 150.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM, Dimensions – carcasse de moteur JM
Motor Frame Selections, Selecciones del Armazón del Motor, Choix de carcasses de moteur

SSH S-Group Frame-Mounted – Dimensions and Weights, SSH Armazón Montado – Dimensiones y Pesos, Dimensions et poids – SSH montée sur palier, groupe S

KEYWAY 1⁄8 x 1⁄4, CHAVETERO 1⁄8 x ¼, LOGEMENT DE CLAVETTE, 1⁄8 x ¼
7⁄16 DIA. – (4) HOLES, 7⁄16 DIA. – (4) AGUJEROS, 4 TROUS, DIAM. : 7⁄16
3⁄8" GAS THREAD UNI ISO 228/1
3⁄8" PAS DU GAZ (UNI ISO 228/1)
Dimensions and Weights – Bare Pump Only, Dimensiones y Pesos – Solamente Bomba, Dimensions et poids – pompe nue seulement
NOTA: 1. Las bombas se transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras. 2. TODAS las dimensiones en pulgadas. 3. No para propósitos de construc- ción.

➀ For use with ANSI class 150 mating flanges. Para usar con bridas que casan ANSI clase 150. À utiliser avec des contre-brides ANSI, classe 150.
7⁄16 – 14 à 20 lbf·pi. 2. Les dimensions sont en pouces, et le poids, en livres. 3. Ne pas utiliser les dimensions pour la construction si elles ne sont pas certifiées à cette effet.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.