Page 2 of the ITT GT07 user manual — WARNING
Page 2 · cliquer pour agrandir
Page 2

Safety Instructions

Engineering Data

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP.

ModelHPPh/HzSuctionDischargeWt. lbs. GT073⁄41/6011⁄2” NPT11⁄2” NPT48 GT10152 GT1511⁄260 GT20265 GT30376 GT0733⁄43/6049 GT103152 GT15311⁄255 GT203269 GT303371

This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage.

DANGER

Warns of hazards that WILL cause serious personal injury, death or major property damage.

WARNING

Warns of hazards that CAN cause serious personal injury, death or major property damage.

  • Piping
  • Pump MUST be installed horizontally on a solid flat surface, with discharge on top.
  • Allow adequate space for servicing and ventilation. Protect the unit from weather and water damage due to rain or flooding or freezing temperatures.
  • Piping should be no smaller than the suction and discharge connections and kept short as possible, avoiding unnecessary fittings to minimize friction losses.
  • All piping MUST be independently supported and MUST NOT place any piping loads on the pump. NOTICE: DO NOT FORCE PIPING INTO PLACE

CAUTION

Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: Indicates special instructions which are very

THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP. MAINTAIN ALL SAFETY DECALS. NOTICE:INSPECT UNIT FOR DAMAGE AND

  • AT PUMP SUCTION AND DISCHARGE CONNECTIONS.
  • All pipe joints MUST be airtight.
  • The use of Teflon TM tape, or equivalent, is recommended for ALL pipe joints. SUCTION
  • Total suction lift, including elevation and pipe friction loss, should not exceed 25 feet of head.
  • Install an airtight union in the suction line close to the pump. See Figure 1.
  • Installation of a foot valve at liquid source is recommended. NOTICE: FOR INSTALLATIONS WITH LONG

REPORT ALL DAMAGE TO THE CARRIER OR DEALER IMMEDIATELY. DO NOT USE PUMP IF DAMAGE IS SUSPECTED.

WARNING

UNITS NOT DESIGNED FOR USE WITH HAZARDOUS LIQUIDS OR FLAMMABLE GASES.

Hazardous Fluids can cause fire, burns or death.

  • Description and Specifications
  • The Model GT embraces a line of end suction, single stage, self-priming centrifugal pumps for lawn sprinkling, HVAC systems, and general water transfer.
  • Casing is cast iron construction with tapped openings provided for vacuum gauge and casing drain.
  • Impellers are enclosed design, glass filled Noryl TM , threaded directly on motor shaft.
  • Standard motors are NEMA standard, 3500 RPM, open drip proof enclosure.
  • SUCTION PIPING, BOTH A FOOT VALVE AND A CHECK VALVE ARE RECOMMENDED.
  • To avoid air pockets, no part of the piping should be above the pump suction connection and piping should slope upward from liquid source.
  • For installations with long suction piping, fill the suction pipe with water before connecting to pump.
Page 3 of the ITT GT07 user manual — WARNING
Page 3 · cliquer pour agrandir
Page 3

DISCHARGE • Install a tee at the discharge connection of the pump. The top opening of the tee is required for initial priming. See Figure 1.

Rotation

NOTICE: INCORRECT ROTATION MAY CAUSE

  • DAMAGE TO THE PUMP AND VOIDS THE WARRANTY.
  • Correct rotation is right hand, CLOCKWISE when viewed from the motor end.
  • Three phase unit rotation may be checked by removing motor end cap or plug and observing rotation of motor shaft. To reverse rotation, reverse any two of the three motor leads.

PRIMING OPENING FUSED OR CIRCUIT BREAKER DISCONNECT MEANS

ITT GT07 — PRIMING OPENING FUSED OR CIRCUIT BREAKER DISCONNECT MEANS diagram (page 3)
Fig. 1

UNION

SUCTION

Operation

WARNING

OPERATION WITHOUT PRIME, OR AGAINST A CLOSED DISCHARGE VALVE, CAN GENERATE HOT WATER OR STEAM CAUSING INJURY OR PROPERTY DAMAGE. NOTICE: DO NOT OPERATE PUMP

Wiring and Grounding

Install, ground and wire according to local and National Electrical Code requirements. Install an all leg electrical power disconnect switch near the pump. Disconnect electrical power before installing or servicing pump.

WARNING

WITHOUT PRIME OR SEAL DAMAGE WILL RESULT.

Extreme heat can cause personal injury or property damage

  • Prime pump by filling pump and piping through opening in top of tee with clean water. See Figure 1.
  • Install pipe plug in top of tee using Teflon TM tape or equivalent. NOTICE: IF PUMP IS DRAINED OR SHUT OFF

Hazardous voltage can shock, burn or cause death.

  • Electrical supply MUST match pump’s nameplate specification. Incorrect voltage can cause fire or damage to the motor and voids warranty. Motors without built-in protection MUST be provided with contactors and thermal overloads for single phase motors, or starters with heaters for three phase motors. See motor nameplate.
  • Follow motor manufacturer’s wiring diagram on the motor nameplate or terminal cover carefully.
  • Use only copper wire to motor and ground. The ground wire MUST be at least as large as the wire to the motor. Wires should be color coded for ease of maintenance. RECOMMENDED MINIMUM WIRE SIZE

DURING PRIMING PERIOD, CASING MUST BE REFILLED BEFORE RESTARTING PUMP. • Start the pump and partially open discharge valve and wait for system pressure to stabilize. If system pressure is surging, or prolonged pressure drop is experienced, the system may not be completely primed.

Maintenance

FAILURE TO DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE CAN CAUSE SHOCK, BURNS OR DEATH. • No lubrication is required on pump. For motor lubrication, refer to and follow manufacturer’s instructions.

WARNING

HPDistance from Service Entrance to Motor 50 Ft. (15 m)100 Ft. (30 m) 150 Ft. (46 m)200 Ft. (61 m) 115 V230 V115 V230 V115 V230 V115 V230 V 3⁄412141014814612 11214814812612 11⁄21014814–12–10 21014814–12–10 3–12–12–10–10

Hazardous voltage can shock, burn or cause death.

  • SEASONAL SERVICE
  • To REMOVE pump from service, remove all drain plugs and drain all piping.
  • To RETURN pump to service, replace all drain plugs using Teflon
  • TM tape or equivalent.
  • Reconnect suction line if removed, examine union and repair if necessary.
  • Reprime and operate pump following all instructions and warnings in the “ OPERATION ” section of manual.
Page 4 of the ITT GT07 user manual — replace as necessary. NOTICE: MECHANICAL SEAL MUST BE REPLACED
Page 4 · cliquer pour agrandir
Page 4

4. Fully and squarely install the seal rotary assembly

Disassembly

against the stationary seat. Be sure rotating seal face does not drop out of holding collar and DO NOT damage seal face. 5. On three phase units, impeller MUST be installed with

WARNING

FAILURE TO DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE CAN CAUSE SHOCK, BURNS OR DEATH.

LOCTITE® “Purple”. Hold shaft from rotating, as explained in the “DISASSEMBLY” section of the manual, and install impeller by turning CLOCKWISE until tight against motor shaft shoulder. 6. Replace diffuser. Align to prevent impeller rub. 7. Install new diaphragm and new diffuser seal ring. 8. Install motor and liquid end into casing. 9. Check impeller for binding by rotating the motor shaft.

Hazardous voltage can shock, burn or cause death.

1. Remove foot bolt (10). 2. Remove casing bolts (12). 3. Remove back pull-out assembly from casing (2). 4. Remove diffuser seal ring (3) and diaphragm (4). 5. Remove diffuser screws (5) from adapter (11). 6. Remove motor end plug or cover. 7. Restrain motor shaft from rotation by utilization of

If binding occurs, loosen casing bolts, readjust diffuser until impeller hub turns freely. Retighten casing bolts in a crossing pattern. 10. Replace all drain plugs and motor end components. 11. Reprime and operate according to instructions in the “OPERATION” section of this manual.

the screwdriver slot, or 7⁄16" shaft flats, accessible at the motor shaft end. 8. Remove impeller (7), turning COUNTER-

Trouble Shooting

CLOCKWISE . 9. Using two screwdrivers, pry off rotary section of

FAILURE TO DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE CAN CAUSE SHOCK, BURNS OR DEATH.

WARNING

mechanical seal (8). Discard. See Figure 2. 10. Remove motor adapter bolts (12) and remove motor adapter from motor. 11. Push stationary seat of mechanical seal out of motor adapter. Discard seal seat.

ITT GT07 — WARNING diagram (page 4)
Fig. 2

Hazardous voltage can shock, burn or cause death.

SYMPTOM Motor Not Running:

See Probable Causes 1 through 5. Little or No Water Delivered:

See Probable Causes 3, 4, 6 through 12, 15. Excessive Noise and Vibration:

See Probable Causes 3, 6, 7, 10, 12, 13, 14. PROBABLE CAUSES 1. Motor thermal protector tripped. 2. Open circuit breaker or blown fuse. 3. Impeller binding. 4. Motor improperly wired. 5. Defective motor. 6. Pump is not primed, air or gases in pumpage. 7. Discharge, suction plugged or valve closed. 8. Incorrect rotation. (3 phase only) 9. Low voltage or phase loss. 10. Impeller worn or plugged. 11. System head too high. 12. NPSHA too low – excessive suction lift or loss. 13. Discharge head too low – excessive flow rates. 14. Pump, motor or piping loose. 15. End of suction piping not submerged.

Reassembly • Clean and inspect all parts before reassembly. 1. Inspect seal seat bore for wear and debris, clean and

replace as necessary. NOTICE: MECHANICAL SEAL MUST BE REPLACED

WHENEVER SEAL HAS BEEN REMOVED. FOLLOW SEAL MANUFACTURER’S INSTRUCTIONS CAREFULLY. 2. If necessary, seat ring may be lubricated with water or

glycerin to aid in installation. DO NOT contaminate the seal face. Fully and squarely install the stationary seat into the adapter. With a clean, lint free cloth, CAREFULLY wipe the seat face clean of debris. DO NOT damage the seal seat face. 3. Reinstall the motor adapter on the motor, making sure

that the motor shaft does not dislocate or damage the stationary seal seat.

Page 5 of the ITT GT07 user manual — Repair Parts List
Page 5 · cliquer pour agrandir
Page 5

Electrical Data

Circuit Breaker ModelHPVoltageFull Load AmpsFuseStandardDelayPh/Hz GT073⁄4115/23013.8/6.945/2545/2525/151/60 GT101115/23016/850/2550/2530/151/60 GT1511⁄2115/23020/1060/3060/3535/201/60 GT20223013.94040251/60 GT303230176060301/60 GT0733⁄4208-230/4603.1-2.8/1.410-10/1010-10/1010-10/103/60 GT1031208-230/4604-3.6/1.815-15/1015-15/1015-10/103/60 GT15311⁄2208-230/4605.7-5.2/2.620-20/1020-20/1015-10/103/60 GT2032208-230/4607.5-6.8/3.425-25/1525-25/1515-15/103/60 GT3033208-230/46010.6-9.6/4.835-30/1535-30/1520-20/103/60

Repair Parts List

Item No.DescriptionMaterialGT07/ GT073GT10/ GT103GT15/ GT153GT20/ GT203GT30/ GT303Motor Codes HP 1Ø – ODP 3Ø – ODP .75 J05853R C05873 1.0 J06853R C06873 1.5 J07858R C07878 2.0 J08854R C08874 3.0 J09854 C09874Motor Codes HP1Ø – ODP3Ø – ODP 11⁄4" NPT Pipe PlugPlated Steel6K2.75J05853RC05873 2CasingCast Iron1K3241.0J06853RC06873 3Guidevane Seal RingBUNA5K2311.5J07858RC07878 4DiaphragmNeoprene5K2562.0J08854RC08874 5Fillister Head Machine ScrewStainless Steel13K413K413K213K213K23.0J09854C09874 6GuidevaneLexan® 10% G.F.3K723K713K703K703K69 7ImpellerNoryl® 20% G.F.2K7152K7162K7142K7132K712 8Mechanical SealCarbon/Ceramic/ BUNA10K10 9Pump FootSteel4K408 10Pump Foot BoltSteel13K252 11Motor AdapterCast Iron1K310 12Casing BoltSteel13K102 13Motor Adapter BoltSteel13K89 14DeflectorBUNA5K7
ITT GT07 — Repair Parts List diagram (page 5)
Fig. 3 · Repair Parts List
Page 6 of the ITT GT07 user manual — Notes
Page 6 · cliquer pour agrandir
Page 6

Notes

Page 7 of the ITT GT07 user manual — Notes
Page 7 · cliquer pour agrandir
Page 7

Notes

Page 8 of the ITT GT07 user manual — GOULDS PUMPS LIMITED WARRANTY
Page 8 · cliquer pour agrandir
Page 8

GOULDS PUMPS LIMITED WARRANTY

This warranty applies to all water systems pumps manufactured by Goulds Pumps. Any part or parts found to be defective within the warranty period shall be replaced at no charge to the dealer during the warranty period. The warranty period shall exist for a period of twelve (12) months from date of installation or eighteen (18) months from date of manufacture, whichever period is shorter. A dealer who believes that a warranty claim exists must contact the authorized Goulds Pumps distributor from whom the pump was purchased and furnish complete details regarding the claim. The distributor is authorized to adjust any warranty claims utilizing the Goulds Pumps Customer Service Department. The warranty excludes: (a) Labor, transportation and related costs incurred by the dealer; (b) Reinstallation costs of repaired equipment; (c) Reinstallation costs of replacement equipment; (d) Consequential damages of any kind; and, (e) Reimbursement for loss caused by interruption of service. For purposes of this warranty, the following terms have these definitions: (1) “Distributor” means any individual, partnership, corporation, association, or other legal relationship that stands between Goulds Pumps and the dealer in purchases, consignments or contracts for sale of the subject pumps. (2) “Dealer” means any individual, partnership, corporation, association, or other legal relationship which engages in the business of selling or leasing pumps to

customers. (3) “Customer” means any entity who buys or leases the subject pumps from a dealer. The “customer” may mean an individual, partnership, corporation, limited

liability company, association or other legal entity which may engage in any type of business.

THIS WARRANTY EXTENDS TO THE DEALER ONLY.

©1999 Goulds Pumps August, 1999 Printed in U.S.A.

Poser une question sur : ITT GT07

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le ITT GT07

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

ITT GT07 manuel PDF

24 pages·532 KB·Pompe à chaleur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…