FR
ITT logo
Notice d'utilisation officielle

ITT Centrifugal Pump (ICS)

32 pages·451 KB·Pompe à eau·PDF·ENDEITNLJA
ITT Centrifugal Pump (ICS)
Table des matières 47 sections ITT · Commercial Water · Goulds Pumps G&L SERIES MODEL ICS/ICS-F · Installation, Operation and Maintenance Instructions · … AfficherMasquer
Page 1 of the ITT Centrifugal Pump (ICS) user manual — www.goulds.com
Page 1 · cliquer pour agrandir
Page 1

ITT

Commercial Water

Goulds Pumps G&L SERIES MODEL ICS/ICS-F

Installation, Operation and Maintenance Instructions

ITT Centrifugal Pump (ICS) — ITT diagram (page 1)
Fig. 1
ITT Centrifugal Pump (ICS) — ITT diagram (page 1)
Fig. 2

Goulds Pumps is a brand of ITT Corporation.

www.goulds.com

Engineered for life

Page 2 of the ITT Centrifugal Pump (ICS) user manual — ITT
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the ITT Centrifugal Pump (ICS) user manual — ITT
Page 3 of the ITT Centrifugal Pump (ICS) user manual — WARNING Hazardous voltage
Page 3 · cliquer pour agrandir
Page 3

SAFETY INSTRUCTIONS

DESCRIPTION and SPECIFICATIONS The Models ICS, close coupled, and ICS-F, frame mounted, are single stage, end suction pumps designed for ultra pure water systems, beverage processing, chemical service and selected OEM applications. The pumps are of back pullout confi guration, with NPT suction and discharge connections and have investment cast AISI Type 316 stainless steel casings, open impellers and seal housing. All pumps are equipped with O-ring shaft sleeve protection and are available with a variety of optional mechanical seals. Close coupled units are equipped with C-face NEMA motors with threaded shaft extensions. Frame mounted units can be baseplate mounted and are available with spacer couplings or may be belt driven. Close coupled units are available with single and three phase ODP, TEFC and explosion proof motors. Consult with your distributor/dealer for additional information. NOTICE: INSPECT UNIT FOR DAMAGE AND REPORT ALL DAMAGE TO CARRIER IMMEDIATELY. MAXIMUM OPERATING LIMITS Liquid Temperature: 212° F (100° C) – standard mechanical seal 250° F (120° C) – OPTIONAL mechanical seal Operating Pressure: 175 PSI (1203 kPa) Starts per Hour: 20, evenly distributed

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN THE MANUAL AND ON THE PUMP.

This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage.

Warns of hazards that WILL cause serious personal injury, death or major property damage.

DANGER

WARNING

Warns of hazards that CAN cause serious personal injury, death or major property damage.

Warns of hazards that CAN cause personal injury or property damage.

CAUTION

THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT. THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

Installation – General

Install, ground and wire accord- ing to local and National Electrical Code Requirements. Install an all leg disconnect switch near the pump. Disconnect and lockout electrical power before installing or servicing the pump. Electrical supply must match motor’s nameplate specifi cations. Incorrect voltage can cause fi re, damage motor and void the warranty. Single phase pump motors are equipped with an automatic thermal protector, which opens the motor’s electrical circuit when an overload condition exists. This can cause the pump to start unexpectedly.

  • Locate the pump as near to the liquid source as possible.
  • If pump repriming capability is required, the pump suction MUST be below the source of the liquid level.
  • Protect the pump and piping from freezing temperatures.
  • Allow adequate space around the unit for service and ventilation.

WARNING

Hazardous voltage can shock, burn or cause death.

Close Coupled Units

  • Units may be installed horizontally, inclined or vertically. DO NOT MOUNT MOTOR BELOW PUMP. FLUID LEAKAGE ONTO MOTOR CAN CAUSE A SHOCK, BURN OR DEATH.
  • Unit foundation must be fl at and substantial to avoid pipe strains when bolts are tightened. Use rubber mounts under motor to minimize noise and vibration.
  • Tighten motor holddown bolts BEFORE connecting the suction and discharge piping.

WARNING Hazardous voltage

Frame Mounted Units

  • Place the baseplate upon the foundation and disconnect the coupling halves. DO NOT reconnect the coupling until the alignment procedures have been completed.
  • It is recommended that the baseplate be grouted to a foundation with a solid footing, per Figure 1.
Page 4 of the ITT Centrifugal Pump (ICS) user manual — Piping – Suction
Page 4 · cliquer pour agrandir
Page 4
ITT Centrifugal Pump (ICS) — Figure 2 Figure 3 diagram (page 4)
Fig. 3 · Figure 2 Figure 3
  • If pump must be installed above the liquid source, the following MUST be provided:
  • To avoid air pockets, no part of the piping should be above the pump suction connection.
  • Slope the piping upward from liquid source.
  • All pipe joints MUST be airtight.
  • Use a foot valve ONLY if necessary for priming or to hold prime during intermittent duty.
  • The suction strainer or suction bell MUST be at least 3 times the suction pipe diameter area.
  • Insure that the size and minimum submergence over suction inlet is suffi cient to prevent air from entering pump through a suction vortex. See Figures 2 through 5.

Base Grout hole (1/4") Finished grouting

(1/2 to 3/4") Allowance for leveling

  • As depicted in Figure 1, place the baseplate on wedges, locating two wedges at each foundation bolt location. A gap of ¾" to 1½" (19 mm to 64 mm) is recommended between the baseplate and the foundation for grouting. Adjust the wedges as necessary to level the baseplate.
  • Inspect baseplate for any distortion, and adjust as necessary. Make sure that any necessary fi nal coupling alignments are possible within the motor movements and shim limits. Tighten the 4 foundation bolts fi nger tight.
  • Build a dam around foundation and pour grout under the baseplate, insuring that the areas under the pump and motor are fi lled completely.
  • Allow grout to harden for 48 hours before tightening 4 foundation bolts.
ITT Centrifugal Pump (ICS) — Figure 2 Figure 3 diagram (page 4)
Fig. 4 · Figure 2 Figure 3

Figure 2 Figure 3

H

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

H = Min. Submergence in feet

3.0D min.

1.5D min.

H min.

D D

D min. 2

1 2 3 4 5 6 7 8 9 10111213141516 V V = Velocity in feet per second = GPM x 0.321

Piping – General

GPM x 0.4085

  • For maximum pump capacity, piping should not be smaller than the pump suction and discharge.
  • To minimize pipe friction losses, avoid unnecessary pipe and fi ttings.
  • All piping MUST be independently supported and MUST NOT place any piping loads on pump. NOTICE: DO NOT FORCE PIPING INTO PLACE AT PUMP SUCTION AND DISCHARGE CONNECTIONS.

D 2

Figure 4 Figure 5

Piping – Discharge

  • Install a check valve, suitable to handle the fl ow and liquids, to prevent backfl ow. After the check valve install an appropriately sized gate valve to be used to regulate the pump capacity, pump inspection and maintenance.
  • When required, the pipe increaser should be installed between the check valve and the pump discharge.

Piping – Suction

ITT Centrifugal Pump (ICS) — Piping – Suction diagram (page 4)
Fig. 5 · Piping – Suction
  • Short and direct suction piping is recommended. For suction lifts of over 10' (3 m) and liquid temperatures over 120 ° F (49 ° C), consult pump performance curve for net positive head required (NPSH R ).
  • If a pipe size larger than the pump suction is required, an eccentric pipe reducer, with the straight side up, MUST be installed at the pump suction.
  • If the pump is installed below the liquid source, install a full fl ow isolation valve in the suction for pump inspection and maintenance. NOTICE: DO NOT USE THE ISOLATION VALVE TO THROTTLE PUMP. THIS MAY CAUSE LOSS OF PRIME, EXCESSIVE TEMPERATURES AND DAMAGE TO PUMP, VOIDING WARRANTY.
  • DISCONNECT AND LOCKOUT THE ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE A SHOCK, BURN OR DEATH.
  • All wiring and grounding connections must be in accordance with Local and National Electrical Code requirements.
  • Use only stranded copper wire to the motor and ground. Wire size MUST limit the maximum voltage drop to 10% of the motor nameplate voltage, at the motor terminals. Excessive voltage drop may affect performance and will void the motor warranty.
  • Single phase motors supplied by Goulds, have built in thermal overloads. Other motors not so equipped MUST use a properly sized contactor and overload. Fuses are permissible.
  • Three phase motors require all leg protection with properly sized magnetic starters and thermal overloads.

Wood frame · Area

Page 5 of the ITT Centrifugal Pump (ICS) user manual — WARNING
Page 5 · cliquer pour agrandir
Page 5

WARNING

DO NOT OPERATE PUMP AT OR NEAR ZERO FLOW. TO DO SO CAN CAUSE EXTREME HEAT, DAMAGE TO THE PUMP, PERSONAL INJURY OR PROPERTY DAMAGE.

Extreme heat can cause personal injury or property damage.

  • After stabilizing the system at normal operating conditions, check the piping and coupling for correct alignments. If necessary, adjust pipe supports and realign the shafts following the procedures provided.

Motor to Pump – Shaft Alignment

  • After completion of the frame mounted unit baseplate installation, the motor and pump shaft alignment MUST be checked, see Figure 6, and the coupling spacer must be reinstalled.
  • Before checking shaft alignment, insure that the foundation, pump and motor holddown bolts are properly tightened.
  • If realignment is required, ALWAYS make the required adjustments to the motor, shimming as necessary.

Maintenance

  • Close coupled pump motors and frame mounted pump frames have permanently lubricated bearings. Additional lubrication is not necessary or possible.
  • Follow the coupling and motor manufacturer’s recommendations regarding maintenance.

Disassembly

DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE A SHOCK, BURN OR DEATH. CASING MAY CONTAIN HAZARDOUS FLUIDS THAT CAN CAUSE SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE.

WARNING Hazardous machinery

WARNING

  • To check for PARALLEL misalignment, place a dial indicator on one coupling hub, rotate the hub 360 ° while observing the indicator readings from the outside diameter of the other hub. Parallel alignment requires a Total Indicator Reading (TIR) of 0.005" (0.13 mm), or less.

Hazardous fluids can cause personal injury or property damage.

  • To check for ANGULAR misalignment, place a dial indicator on one coupling hub, rotate the hub 360 ° while observing the indicator readings from the face of the other hub. Angular alignment requires 0.005" (0.13 mm) TIR, or less.
  • Drain and fl ush system, as required.
  • For close coupled or frame mounted units:
  • Remove the motor or bearing frame holddown bolts
  • Remove the coupling guard and coupling spacer
  • Correct alignment is achieved when parallel and angular TIR requirements are satisfi ed and motor holddown bolts are tight. NOTICE : RECHECK SHAFT ALIGNMENT AFTER MAKING ANY ADJUSTMENTS.
  • Remove the 4 casing screws (370), then utilizing the slots provided about the casing (100), pry the back pull-out assembly from casing. Carefully remove the casing shims.

Operation

WARNING

DO NOT OPERATE UNIT WITHOUT SAFETY GUARD IN PLACE. TO DO SO CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.

  • To remove the impeller it is necessary to heat the center hub area with a hand propane torch for approximately 30 seconds. Unscrew the impeller (101) from the shaft, turn the impeller COUNTERCLOCKWISE while holding the shaft. Motors have a screwdriver slot or hex provided under the motor end cap. Examine the impeller for wear or damage and replace as necessary. Discard the shaft sleeve O-ring (412A).

Hazardous machinery can cause personal injury or death.

  • To remove the mechanical seal, remove the 4 seal housing screws (370H) and slide the seal housing assembly off the shaft. Discard the rotary half of the seal and the seal housing O-ring (513). With an appropriately sized screwdriver handle, push the stationary half of the seal from the seal housing and discard it.

Parallel · Angular

Page 6 of the ITT Centrifugal Pump (ICS) user manual — WARNING Hazardous voltage
Page 6 · cliquer pour agrandir
Page 6
  • To remove the shaft sleeve (126) it is necessary to evenly heat the outside of the sleeve, with a hand propane torch, while prying between the shaft shoulder and the sleeve. NOTICE : EXERCISE CARE HANDLING THE HOT SHAFT SLEEVE.
  • Removal of the 4 motor adapter screws (371) and motor adapter (108) from the motor completes the close coupled unit disassembly.
  • Disassembly of the bearing frame assembly is accomplished by removing the 4 frame adapter screws (371) and removing the frame adapter (108) from the bearing frame (228).
  • Remove the 4 bearing cover (370C) screws, being careful not to damage the lip seal (139). Inspect lip seal for damage and replace as required.
  • Remove the shaft assembly from the bearing frame, by pulling the motor end of shaft out of the housing.
  • Being careful not to damage the shaft, remove the snap ring (361) and outer bearings (112) from the shaft. If required remove the inner bearing (168). Inspect the bearings for wear or damage and replace as necessary.
  • Inspect the inner lip seal (138) and replace as required.
  • Disassembly is complete.
  • Shim pack (330) permits renewal of impeller clearance to compensate for impeller or casing wear. The shim thicknesses, in the shim pack, range from 0.003" to 0.025" (0.08 mm to 0.64 mm). The factory shim pack thickness is approximately 0.060" (1.52 mm). To set the suggested nominal impeller clearance of 0.020" (0.51 mm) proceed as follows:
  • Establish a shim pack thickness that allows for the impeller to just touch the inside of the casing surface, when pump is assembled.
  • Add an additional 0.020" (0.51 mm) thickness of shims.
  • When the proper impeller clearance has been achieved, install and tighten the 4 casing screws.
  • Install the 4 bearing frame holddown bolts for the frame mounted units or the 4 motor holddown bolts for the close coupled units.
  • On frame mounted units, check the coupling alignment as specifi ed in the “MOTOR TO PUMP – SHAFT ALIGNMENT” section of this manual.
  • Inspect unit rotation for binding and correct as required.
  • Reinstall the safety guard.
  • Reassembly is complete.

Troubleshooting Guide

Reassembly

DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE A SHOCK, BURN OR DEATH.

  • Reassemble the bearing frame assembly in reverse order of disassembly. Use appropriate tools for bearing installation and press ONLY on inner bearing race. Press bearings squarely and completely onto the shaft.
  • If the shaft sleeve was replaced, it is required that the new sleeve be bonded to the shaft using Loctite TM #243 or equivalent. Following the manufacturer’s instructions in the preparation of the sleeve and shaft, apply bonding agent to the surfaces then slide the sleeve over the shaft. Remove all excess bonding agent.
  • Install the shaft assembly into bearing frame. DO NOT damage the inner lip seal.
  • Insert and tighten the 4 bearing cover screws.

WARNING Hazardous voltage

SYMPTOM MOTOR NOT RUNNING See Probable Cause – 1 through 5 LITTLE OR NO LIQUID DELIVERED BY PUMP See Probable Cause – 6 through 13 POWER CONSUMPTION TOO HIGH See Probable Cause – 3, 13, 14, 15, 18 EXCESSIVE NOISE and VIBRATION See Probable Cause – 3, 6, 7, 8, 10, 12, 14, 16, 17, 18

  • Install the bearing adapter, nameplate towards the TOP , using the 4 screws.
  • Inspect and remove any debris from the seal housing stationary seat bore. Lubricate the outside diameter of the new stationary seat with a good quality O-ring lubricant and press seat squarely and completely into the seal housing. With a clean, lint free cloth remove any debris or lubricant from the seat face. DO NOT scratch the face.
  • Install a new seal housing O-ring on housing, then carefully slide seal housing over shaft and attach housing to the motor adapter with the 4 screws. DO NOT damage the mechanical seal stationary seat.
  • Install the new shaft sleeve O-ring.
  • Slide the new mechanical seal rotary assembly over shaft sleeve. Apply Loctite™ 7649 and allow to dry. Apply Loctite™ #243 to the motor shaft thread and then screw on the impeller by turning impeller CLOCKWISE . Torque the impeller to 12 ft lbs (1.7 kg/m).

PROBABLE CAUSE 1. Motor thermal protector tripped 2. Open circuit breaker or blown fuse 3. Impeller binding 4. Motor improperly wired 5. Defective motor 6. Pump is not primed, air or gases in pumpage 7. Discharge, suction plugged or valve closed 8. Incorrect rotation (3 phase only) 9. Low voltage or phase loss 10. Impeller worn or plugged 11. System head too high 12. NPSHA too low – Suction lift or suction losses excessive 13. Incorrect impeller diameter 14. Discharge head too low – excessive fl ow rate 15. Fluid viscosity, specifi c gravity too high 16. Worn bearing 17. Pump, motor or piping loose 18. Pump and motor shafts misaligned

Page 7 of the ITT Centrifugal Pump (ICS) user manual — Parts List and Materials of Construction
Page 7 · cliquer pour agrandir
Page 7

ICS & ICS-F Sectional Assemblies

184 513 370 383 371 126

184 513 370 383 371 138 168 122 112 370C

ITT Centrifugal Pump (ICS) — ICS & ICS-F Sectional Assemblies diagram (page 7)
Fig. 6 · ICS & ICS-F Sectional Assemblies
ITT Centrifugal Pump (ICS) — ICS & ICS-F Sectional Assemblies diagram (page 7)
Fig. 7 · ICS & ICS-F Sectional Assemblies

412A

412A

408 Optional, 408 Opcional

408 Optional, 408 Opcional 108

Parts List and Materials of Construction

Item No.Number/PumpPart NameMaterial 1001Casing – 1 x 1¼ - 5ASTM A744 Grade CF-8M 1Casing – 1¼ x 1½ - 5ASTM A744 Grade CF-8M 1011ImpellerASTM A744 Grade CF-8M 1261Shaft SleeveASTM A276 Type 316 SS 1841Seal HousingASTM A744 Grade CF-8M 330*1Shim PackMylar 3704Hex Cap Screws – adapter to casingASTM A276 Type 304 SS 370H*4Hex Cap Screws – adapter to seal housingASTM A276 Type 304 SS 3831Mechanical Seal (standard)Carbon/Sil Car/Viton Mechanical Seal (optional)Carbon/Sil Car/EPR 412A1O-ring – Shaft SleeveViton 5131O-ring – Seal HousingViton
Item No.Number/PumpPart NameMaterial 1081Motor and Bearing Frame AdapterASTM A48 Cast Iron 1091Bearing CoverASTM A48 Cast Iron 1121Ball Bearing – outboardASTM A108 Steel 1221Pump ShaftASTM A276 Type 303 SS 1681Ball Bearing – inboardASTM A108 Steel 3611Snap Ring – outboard bearingASTM A108 Steel 2281Bearing FrameASTM A48 Cast Iron 1381Lip Seal – innerBUNA-N and ASTM A108 Steel 1391Lip Seal – outerBUNA-N and ASTM A108 Steel 370C4Hex Cap Screws – bearing cover to bearing frameASTM A108 Steel 3714Hex Cap Screws – adapter to motor/bearing frameASTM A276 Type 304 SS
Page 8 of the ITT Centrifugal Pump (ICS) user manual — Available Motor Weights and Dimensions
Page 8 · cliquer pour agrandir
Page 8

ICS – Engineering Data

ITT Centrifugal Pump (ICS) — ICS – Engineering Data diagram (page 8)
Fig. 8 · ICS – Engineering Data

½ HP – 2 HP

4.88 MAX. R

58317 CF–8M

2.94 2.94 6.75

Dimensions and Weights – Determined by Pump

PumpSuction NPTDischarge NPTLRWX*Wt. Max. 1 x 1¼-51¼13.75.943.014.6217 1¼ x 1½-51½1¼3.621.062.884.5617

Available Motor Weights and Dimensions

HPMotor WeightsC Max. Length Single PhaseThree Phase ODPTEFCEXPODPTEFCEXP ½162147191827915⁄16 ¾19244121213010¼ 122264923213011 1½283556272737115⁄16 2333960323344121⁄16
3 HP Only 5.28 3HP 1 PHASE ONLY 1.59 W C MAX. 4.88 3.50 R DISCHARGE MAX. SINGLE PHASE ONLY 5.31 X SUCTION MAX. 7.10 MAX. 58317 CF–8M 3.50 3.382.88 .19 2.44 2.44 L 1.5 1.5 6.50 1⁄4 NPT (OPTIONAL) 5.88 SLOT .34 WIDE X .88 C L TOCL Dimensions and Weights – Determined by Pump Available Motor Dimensions and Weights Pump Suction NPT Discharge NPT L R W X *Wt. Max. Motor Weights 1 x 1¼-5 1¼ 1 7.35 .94 3.01 4.62 17 HP Single Phase Three Phase C Max. Length 1¼ x 1½-5 1½ 1¼ 7.22 1.06 2.88 4.56 17 ODP TEFC ODP TEFC X-Proof 3 40 45 42 37 — 13.34 Motor Weights Single Phase Three Phase ODP TEFC ODP TEFC X-ProofC Max. Length Three Phase TEFCODPTEFCX-Proof 40454237—13.34
PumpSuction NPTDischarge NPTLRWX*Wt. Max. 1 x 1¼-51¼17.35.943.014.6217 1¼ x 1½-51½1¼7.221.062.884.5617

Dimensions in inches, weight in pounds.

Page 9 of the ITT Centrifugal Pump (ICS) user manual — HG
Page 9 · cliquer pour agrandir
Page 9

ICS-F – Engineering Data

Pump Dimensions and Weights

ITT Centrifugal Pump (ICS) — Pump Dimensions and Weights diagram (page 9)
Fig. 9 · Pump Dimensions and Weights
ITT Centrifugal Pump (ICS) — Pump Dimensions and Weights diagram (page 9)
Fig. 10 · Pump Dimensions and Weights

5.88 MAX.

58317 CF–8M

HD

4 HOLES .62 DIA.

HG

HE HE

HA

Dimensions and Weights – Determined by Pump

PumpSuction NPTDischarge NPTCPLRWXWt. Max.HL (Motor Frame) 56140180 1 x 1¼-51¼112.16 5.73.943.014.62385.733.85 1¼ x 1½-51½1¼12.03 5.601.062.884.56385.603.72 NOTES: 1. Pumps will be shipped with top vertical discharge as standard, for other 2. Dimensions in inches, weight in pounds. orientations, remove casing bolts, rotate to desired position, and tighten 3. Not to be used for construction purposes unless certifi ed. 3⁄8" bolts to 24 lbs.-ft. 4. Motor dimensions may vary with motor manufacturers. Available Motor and Bedplate Dimensions and Weights Motor FrameHAHBHDHEHFHGHPWt. Max.ShimsHorsepower – 3500 RPMWt. Max.C Max. Single PhaseThree Phase ODPTEFCODPTEFC 568266.873.1222.382.381.00 30½ 1.00- 1½½1½½1½14513 143T——1½1½4513.38 145T222-325214.25 182T107.253.75242.75.8843—33536316.62 184T55—511218.12

Dimensions in inches, weight in pounds.

Page 10 of the ITT Centrifugal Pump (ICS) user manual — IM011R04 March, 2007 © 2007 ITT Corporation Engineered for life
Page 10 · cliquer pour agrandir
Page 10

ITT

Commercial Water

GOULDS PUMPS LIMITED WARRANTY This warranty applies to all water systems pumps manufactured by Goulds Pumps. Any part or parts found to be defective within the warranty period shall be replaced at no charge to the dealer during the warranty period. The warranty period shall exist for a period of twelve (12) months from date of installation or eighteen (18) months from date of manufacture, which- ever period is shorter. A dealer who believes that a warranty claim exists must contact the authorized Goulds Pumps distributor from whom the pump was purchased and furnish complete details regarding the claim. The distributor is authorized to adjust any warranty claims utilizing the Goulds Pumps Customer Service Department.

The warranty excludes: (a) Labor, transportation and related costs incurred by the dealer; (b) Reinstallation costs of repaired equipment; (c) Reinstallation costs of replacement equipment; (d) Consequential damages of any kind; and, (e) Reimbursement for loss caused by interruption of service.

For purposes of this warranty, the following terms have these defi nitions: (1) “Distributor” means any individual, partnership, corporation, association, or other legal relationship that stands between Goulds Pumps and the dealer in purchases, consignments or contracts for sale of the subject pumps. (2) “Dealer” means any individual, partnership, corporation, association, or other legal relationship which engages in the business of selling or leasing pumps to customers. (3) “Customer” means any entity who buys or leases the subject pumps from a dealer. The “customer” may mean an individual, partnership, corporation, limited liability company, association or other legal entity which may engage in any type of business.

THIS WARRANTY EXTENDS TO THE DEALER ONLY.

Goulds Pumps, G&L and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporaton. Loctite is a registered trademark of Loctite Corporation. Tefl on is a registered trademark of Dupont.

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

IM011R04 March, 2007 © 2007 ITT Corporation Engineered for life

Page 11 of the ITT Centrifugal Pump (ICS) user manual — www.goulds.com
Page 11 · cliquer pour agrandir
Page 11

ITT

Agua Industrial

Goulds Pumps SERIE G&L MODELO ICS/ICS-F

Instrucciones de instalación, funcionamiento y mantenimiento

Goulds Pumps es una marca de ITT Corporation.

www.goulds.com

Engineered for life

Poser une question sur : ITT Centrifugal Pump (ICS)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le ITT Centrifugal Pump (ICS)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

ITT Centrifugal Pump (ICS) manuel PDF

32 pages·451 KB·Pompe à eau·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…