ITT
Commercial Water
Variable Speed Water Booster with Vertical Multistage Pump and Fused Disconnect

Engineered for life
Listed





using a bracket.
The pump package comes pre-assembled and tested, complete with operating instructions and panel wiring diagram.
Listed

PACKAGED HYDROVAR VARIABLE SPEED SSV PRODUCT LINE NUMBERING SYSTEM The various versions of the PHV line are identified by a product code number on the pump label. The number is also the catalog number for the package. The meaning of each digit in the product code is shown below.
Reduced Stages (33-46SV Only) (can be 0, 1 or 2)*: 0 = 0 reduced 1 = 1 reduced 2 = 2 reduced
Number of Stages: A = 1 E = 5 J = 9 N = 13 S = 17 Z = 24 B = 2 F = 6 K = 10 P = 14 T = 18 C = 3 G = 7 L = 11 Q = 15 V = 20 D = 4 H = 8 M = 12 R = 16 X = 22
Pump Model: 1 = 1SV 2 = 2SV 3 = 3SV 4 = 4SV 5 = 33SV 6 = 46SV 7 = 66SV 8 = 92SV
* Notes: Indicates num ber of reduced diameter impellers in the total staging. (2 would indicate 2 reduced diameter impellers.)
HP Rating: 02 = 2 HP 03 = 3 HP 05 = 5 HP 07 = 7½ HP 10 = 10 HP 15 = 15 HP
PHV - Series (SSV & Hydrovar Package)
HYDROVAR VARIABLE SPEED CONTROLLERS Hydrovar variable speed drives are identified by the following code. The meaning of each digit in the product code is shown below.
HP Rating: 02 = 2 HP 03 = 3 HP 05 = 5 HP 07 = 7 HP 10 = 10 HP 15 = 15 HP
HV - Series

Booster MARKETS SERVED Sets MUNICIPAL, COMMERCIAL, INDUSTRIAL








The PHV series booster sets use a Hydrovar® variable frequency drive, an automatic device that adjusts the speed of the electric pump in order to maintain constant pressure in the system.
Converters with power up to 30 HP can be mounted directly on to the motor. Models with over 30 HP power, are designed for wall mounting only. The pressure is measured by a pressure transmitter which uses a standard 4..20 mA current signal. The system pressure value can be read on the converter’s display. A simple user interface allows you to set the desired pressure value for optimal adjustment, as well as to view the operating data, such as the hours of operation and any alarms triggered. Included diagnostic menu to view temperature, current and voltage values facilitates diagnostics and failure analisys. Indicator lights signal power status, pump running and malfunctions.

Modular Hydrovar, Bare Unit
A password is required to access sensitive settings that allow you to program the Hydrovar in order to adapt it to any control requirements, such as flow resistance compensation, external control, periodic testing and so on. When more than one pump is used, the converters exchange information with each other through an RS485 serial line which can connect up to 8 Hydrovar devices plus one external unit for remote control. The Pump-link and Pump-watcher dedicated systems, connected to the Hydrovar®, enable remote control through a traditional telephone line or mobile telephony. A serial port available as standard up to 15 HP allows you to control the Hydrovar® converters from a Modbus® field serial bus line.

The converter is equipped with two potential-free relays which can be used for remote signalling of pump running and malfunction status, plus a programmable voltage analogue output for signalling the frequency or pressure. Standard version with two sensor inputs for implementing of two actual values signals within one system (min/ max, difference) or for a second sensor for safety reasons. Specific digital inputs are used for protection against water failure, motor overtemperature, as well as for external enable signal and remote control. The converter also incorporates a dry running protection function via an adjustable minimum pressure threshold.
FCC Class A filter standard for Hydrovar three-phase power supply. E.g. Industrial areas, technical areas of any building fed from a dedicated transformer are examples of environment locations.
PHV Series Hydrovar with SSV Pump
FCC Class B filter standard for Hydrovar single-phase power supply. E.g. Houses, apartments, commercial premises or offices in a residential building are examples of environment locations.
Further information is available in the Hydrovar manual.

1, 2, 3 AND 4 SSV VERTICAL MULTI-STAGE PUMPS

The HYDROVAR Concept consists mechanically of two main parts, the Power Unit and the Control Card. In its basic configuration (consists only of the Power Unit) the HYDROVAR can be used as a “Basic Inverter” without the need of the Control Card. In that form the HYDROVAR can be used as a sequence pump in a multi pump system, with at least one master inverter. By extending this “Basic Inverter” with the additional Control Card and LCD display, the HYDROVAR “Master Unit” is able to work in different modes and can be extended by the implementation of different modules.
CASCADE SERIAL (MASTER + BASIC)
In this mode there are various possibilities to combine the different versions of the HYDROVAR. In general, each of the pumps is equipped with a HYDROVAR unit. Each pump of the system (extended up to 8 pumps) is equipped with a HYDROVAR unit (at least one “Master Inverter” and the others can be “Basic Inverters” in order to ensure a proper control of the system) which are connected via the serial interface. Minimum requirement: One “Master Inverter” and the others equipped with “Basic Inverters”.
The whole control is performed via the “Master Inverter” every time, but also an automatic change over of the lag pumps to achieve even operating hours is possible.
Following versions are available:
- PHV: one pump with wiring, fused disconnect, master Hydrovar drive, transducer, conduit.

MASTER INVERTER
MASTER INVERTER
MASTER INVERTER

With the “master” version of the Hyrdrovar, it is possible to connect up to 8 Hydrovar controller pumps together in parallel. Complete lead/lag and auto alternation.
BASIC INVERTER
BASIC INVERTER
BASIC INVERTER

Reduction of overall cost for multi-pump system is possible using one “master” controller and several “basic” con trollers. The Hydrovar “master” will still control lead/lag, alternation.

The starting and stopping of the pumps are determined based on the pressure values set on the controller. Each frequency converter is connected to a pressure transducer. The controllers exchange information with each other and provide for cyclic changeover.
The figure shows the operating mode of a two-pump booster set (Typical Field Set).
OPERATING CHARACTERISTICS AND LIMITS
Type of pumped liquids Water containing no gas or corrosive and/or aggressive substances Fluid temperature Above 0° F to 180° F, Pressure transducer limited Ambient temperature Above 0° F to 104° F, VFD/Display, keep away from direct sun Maximum operating pressure 360 PSI (Pump without transducer) Minimum inlet pressure According to NPSH curve and losses, with a minimum margin of 0.5 m Maximum inlet pressure The inlet pressure added to the pressure of the pump at zero flow must be lower than the maximum operating pressure of the set (suction and discharge). Installation Indoors/outdoors, protected from the direct sun. Away from heat sources. Maximum elevation 3300 feet ASL. Maximum humidity 50% without condensation. Hourly starts Maximum 60 up to 10 HP. Above 10 HP and up to 50 HP, maximum 40 starts per hour. Variable speed drive starts. Sound emission See table
* Note: For higher temperature it is necessary to use special materials (only on request).
HP NEMA Motor Frame PHV 1 56 < 70 2 56 < 70 3 56 < 70 5 145 < 70 7½ 182-184 < 70 10 215 < 70 15 254 73 20 256 75 25 284 75 30 284 75
* Note: Adjusted from 50 Hz data, may vary.

The first thing to do when selecting a package is to determine the quantity of water required and the pressure it must supply.
The booster sets are ready for installation of diaphragm tanks directly on the delivery manifold, and additional tanks can be connected to the unused end of the manifold.
For peak performance, variable speed booster sets need smaller tanks compared to traditional systems. Generally speaking, a tank with a capacity of just 20% of the nominal capacity of a single pump, expressed in gallons per minute, is required. Example: If my pump is sized for 100 GPM, then we would size a 20 gallon (total capacity) diaphragm tank.

DISCONNECT FUSE BLOCK
HYDROVAR
SINGLE
12 AWG
U1
U2
PHASE
MTR MOTOR
CUSTOMER SUPPLIED
VOLTAGE
12 AWG
W1
W2
GND
GND PE
16 AWG GND
CUSTOMER SUPPLIED
DISCONNECT FUSE BLOCK
HYDROVAR
12 AWG
THREE PHASE
U1
U2
L2 12 AWG
MTR MOTOR
CUSTOMER SUPPLIED
12 AWG
VOLTAGE
W1
W2
16 AWG GND
GND
GND PE
ITT Input HP / AMP Wire Tightening Fuse AMP Part Voltage Disconnect Voltage Disconnect Rating Range Torque Supplier Rating Number Rating Part Number
HFD512C1 230/1/60 OT25F3 2 HP / 25A #18-8AWG 7 IN/LB Bussman 20 KTK-R-20 600V
HFD512E1 230/1/60 OT40F3 3 HP / 40A #18-8AWG 7 IN/LB Bussman 30 KTK-R-30 600V
HFD534A1 460/3/60 OT16F3 3 HP / 16A #18-8AWG 7 IN/LB Bussman 10 KTK-R-10 600V
HFD534B1 460/3/60 OT16F3 3 HP / 16A #18-8AWG 7 IN/LB Bussman 15 KTK-R-15 600V
HFD534C1 460/3/60 OT25F3 3 HP / 25A #18-8AWG 7 IN/LB Bussman 20 KTK-R-20 600V
HFD534C2 460/3/60 OT25F3 3 HP / 25A #18-8AWG 7 IN/LB Bussman 20 KTK-R-20 600V
HFD534E2 460/3/60 OT40F3 3 HP / 40A #18-8AWG 7 IN/LB Bussman 30 KTK-R-30 600V

HP Model * Power Supply (V) NEMA Class Install. Power Supply (V) HP 2 HVM1202 1x230 4 TEFC Motor 3x230 2 3 HVM1203 1x230 4 TEFC Motor 3x230 3 3 HVM3403 3x460 4 TEFC Motor 3x460 3 5 HVM3405 3x460 4 TEFC Motor 3x460 5 7½ HVM3407 3x460 4 TEFC Motor 3x460 7½ 10 HVM3410 3x460 4 TEFC Motor 3x460 10 15 HVM3415 3x460 4 TEFC Motor 3x460 15
* The new Hydrovar is available single-phase up to 3 HP and 3 HP through 15 HP, 460 volt.
The GHV sets come with a fused disconnect on which are installed automatic line protection fast acting fuses for each drive. Class J, 600 volt.
Single-pump sets are supplied as standard with an electrical panel encased in NEMA 4X enclosure, with 2-pole or 3-pole (3 phase) up to 30 amps and featuring a main switch.
The fused disconnect is rated for UL508A.


Pump Disconnect Switch

HP Phase Enclosure Nameplate NEMA Goulds FLA SFA LRA S.F. Efficiency Insulation Voltage Frame PN ¹ Class
1 3 TEFC 230/460 56C V06742 3.7-3.6/1.8 3.99-3.8/1.9 11 1.25 75.5 B
Prem. Eff. TEFC 230/460 56C V06742PE 2.8/1.4 3.12/1.56 12.1 1.25 84.5 B
1½ 3 TEFC 230/460 56C V07742 4.9-4.6/2.3 5.3-5.1/2.54 18.4 1.15 80 B
Prem. Eff. TEFC 230/460 56C V07742PE 4.0/2.0 4.5/2.25 20.1 1.15 85.5 B
2* 3 TEFC 208-230/460 56C V08742 6.2-5.8/2.9 7.2-6.52/3.26 22 1.15 80 B
Prem. Eff. TEFC 208-230/460 56C V08742PE 5/4.75-2.5 6.4-5.8/2.9 30 1.15 86.5 B
3* 3 TEFC 208-230/460 56C V09742 8.1-7.6/3.8 9.5-8.6/4.3 32.9 1.15 82.5 F
Prem. Eff. TEFC 208-230/460 184TC V09742PE 6.8/3.4 8.5-7.7/3.8 32 1.15 88.5 F
5* 3 TEFC 208-230/460 184TC V10742A 13.2-12/6 15-13.6/6.8 47 1.15 85.5 F
Prem. Eff. TEFC 208-230/460 184TC V10742APE 11.2/5.7 14.4-13/6.5 55 1.15 90.2 F
7½* 3 TEFC 208-230/460 184TC V11742A 18.5/17.4 21.7-19.6/9.8 94 1.15 88.5 F
Prem. Eff. TEFC 230/460 213TC V11742APE 17.8/8.9 20.2/10.1 75 1.15 90.2 F
10* 3 TEFC 208-230/460 215TC V12742 25-24/12 30.5-27.6/13.8 105 1.15 85.5 F
Prem. Eff. TEFC 230/460 215TC V12742PE 23.8/11.9 27.6/13.8 112 1.15 89.5 F
15* 3 TEFC 208-230/460 254TC V13742 35/17.5 43-39/19.5 165 1.15 86.5 F
Prem. Eff. TEFC 208-230/460 254TC V13742PE 34.4/17.2 43.8-39.6/19.8 112 1.15 91.7 F
20 3 TEFC 208-230/460 256TC V14742 46/23 59.3-53.6/26.8 160 1.15 89.5 F
Prem. Eff. TEFC 208-230/460 256TC V14742PE 46/23 57.5-52/26 201 1.15 92.4 F
25 3 TEFC 230/460 284TC V15742 59/29.5 74.8-67.6/33.8 182 1.15 88.5 F
Prem. Eff. TEFC 230/460 284TC V15742PE 56/28 69.9-63.2/31.6 236 1.15 93 F
30 3 TEFC 230/460 284TC V16742 68/34 86.7-78.4/39.2 225 1.15 91 F
Prem. Eff. TEFC 230/460 286TC V16742PE 66/33 83.8-75.8/37.9 281 1.15 93 F
40 3 TEFC 230/460 284TC V17742 90/45 103.2/51.6 322 1.15 90.2 F
Prem. Eff. TEFC 230/460 324TSC V17742PE 90/45 102.2/51.1 286 1.15 93.6 F
50 3 TEFC 230/460 326TSC V18742S 112/56 141.8-128.2/64.1 430 1.15 92.4 F
Prem. Eff. TEFC 230/460 326TSC V18742SPE 108/54 124.8/62.4 422 1.15 94.1 F
¹ Locked rotor amps are for high voltage only.
* Currently available on Packaged Hydrovar.
Above data is for Baldor® TC and TSC frame motors. Specifications subject to change without notice.

Fitting the electric pump with a variable speed drive makes it possible to vary the pump rotation speed, normally accor ding to the system pressure parameter. Variations in electric pump speed result in modified performances according to the equivalence relations, called affinity laws.
Q1 = n1 Q2 n2
n1
A
H1
H1 = n1 H2 n2
n2
H2
B
P1 = n1 P2 n2
Q1 Q2 Q
n1 = initial speed; n2= speed required. Q1 = initial flow rate; Q2= flow rate required. H1 = initial head; H2= head required. P1 = initial power; P2= power required
Frequency ratios can be used instead of speed in practical applications, keeping 30 Hz as the bottom limit.
Example : 2-pole 50 Hz electric pump n1 =2900 (point A) Flow rate (A) = 100 l/min; Head (A) = 50m By reducing the frequency to 30 Hz the speed is reduced to approx. n2 = 1740 rpm (point B) Flow rate (B) = 60 l/min; Head (B) = 18 m The power of the new work point B is cut to about 22% of the initial power.
Variable speed booster sets need smaller tanks compared to traditional systems. Generally speaking, a tank with a capacity of just 20% of the nominal capacity of a single pump, expressed in gallons per minute, is needed. The gradual starting of the pumps controlled by the drive reduces the need to limit the number of hourly starts; the main purpose of the tank is to compensate for small system losses, stabilize the pressure and make up for pressure variations caused by sudden demand (fast acting valves).
Make the following calculation: Set made up of three electric pumps, each with a maximum flow rate of 100 GPM, for a total capacity of 300 GPM. The volume required for the tank is 20 gallons. This is total capacity, not drawdown. Mount downstream of the check valves in discharge manifold.

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 22 US GPM 298 feet
Head

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 22 US GPM 442 feet
44.5%
44.5%
44.5%
Head

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 22 US GPM 733 feet
600 640 680 720
44.5%
200 240 280 320 360 400
44.5%
44.5%
44.5%
1.5 2 2.5 3
Head · 480 520 560 · 80 120 160

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 40 US GPM 217 feet
120 130 140 150 160 170 180 190
57.1%
0 10 20 30 40 50 60 70 80 90 100 110
57.1%
57.1%
0.6 0.8 1 1.2
26 28 30 32 34 36 38 40 42
200 210 220

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 40 US GPM 353 feet
57.1%
57.1%
57.1%
26 28 30 32 34 36 38 40 42

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 40 US GPM 586 feet
57.1%
57.1%
57.1%
26 28 30 32 34 36 38 40 42
Head

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 78 US GPM 441 feet
28 32 36 40
44 48 52 56 60 64 68 72 76 80 84

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 78 US GPM 565 feet
28 32 36 40
44 48 52 56 60 64 68 72 76 80 84

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 78 US GPM 817 feet
28 32 36 40
44 48 52 56 60 64 68 72 76 80 84

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 112 US GPM 148 feet
3.5 4 4.5
30 Hz 40 Hz
60 70 80 90
100 110

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 112 US GPM 299 feet
5 6 7 8
30 Hz 40 Hz
60 70 80 90
100 110

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 111 US GPM 526 feet
30 Hz 40 Hz
120 5 15 25 35 45 55 65 75 85 95 105 115
60 70 80 90
100 110

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 225 US GPM 83 feet
STAGE 1/1
2.5 3 3.5
140 160 180 200 220

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 224 US GPM 110 feet
90 95 100 105 110 115
70 75 80 85
76.7%
40 45 50 55 60 65
76.7%
76.7%
20 25 30 35
76.7%
4 4.5 5
2.5 3 3.5
140 160 180 200 220

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 225 US GPM 191 feet
120 130 140 150 160 170 180 190 200
76.7%
76.7%
76.7%
76.7%
6 7 8 9
140 160 180 200 220
100 110 · 40 50 60

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 225 US GPM 310 feet
76.7%
76.7%
76.7%
76.7%
STAGE 3/1 (P2)
140 160 180 200 220
10 12 14

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 319 US GPM 100 feet
85 90 95 100 105
55 60 65 70 75 80
30 35 40 45 50
77.6%
77.6%
77.6%
30 Hz 40 Hz
77.6%
STAGE 1/1 (P2)
2.5 3 3.5
30 Hz 40 Hz
140 160 180 200 220
240 260 280 300 320 340

Hydraulic Data Maximum Flow Flow at Duty Point Maximum TDH TDH at Duty Point NPSHR 319 US GPM 123 feet
110 115 120 125 130
85 90 95 100 105
55 60 65 70 75 80
77.6%
77.6%
30 35 40 45 50
77.6%
77.6%
STAGE 1 (P2)
140 160 180 200 220
240 260 280 300 320 340

1SV 3500 RPM Number of Maximum Motor HP for use Motor HP for use Shutoff Shutoff Stages HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation Draw Motor (1.0 SF) (Feet) (Bar) 22 6.7 7.5 7.5 1100 32.8 20 6.1 7.5 7.5 1005 30.0 580 PSI (40 Bar) CCW 18 5.4 5 7.5 905 27.0 16 4.8 5 5 795 23.7 15 4.6 5 5 742 22.2 13 4 5 5 642 19.2 11 3.4 3 5 550 16.4 9 2.7 3 3 445 13.3 8 2.4 3 3 398 11.9 362 PSI (25 Bar) CW 7 2 2 2 350 10.4 6 1.8 2 2 300 9.0 5 1.5 1.5 1.5 250 7.5 4 1.1 1 1.5 200 6.0 3 0.9 3/4 1 142 4.2 2 0.6 1/2 3/4 100 3.0
2SV 3500 RPM Number of Maximum Motor HP for use Motor HP for use Shutoff Shutoff Stages HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation Draw Motor (1.0 SF) (Feet) (Bar) 22 7.7 7.5 NA 950 28.4 20 6.8 7.5 7.5 860 25.7 580 PSI (40 Bar) CCW 18 6.2 7.5 7.5 760 22.7 16 5.3 5 7.5 726 21.7 15 4.9 5 5 680 20.3 13 4.6 5 5 595 17.8 11 4 5 5 500 14.9 9 3.3 3 5 407 12.2 8 2.9 3 3 360 10.7 7 2.4 3 3 315 9.4 362 PSI (25 Bar) CW 6 2.1 2 3 270 8.1 5 1.8 2 2 222 6.6 4 1.5 1.5 1.5 175 5.2 3 1.1 1 1.5 137 4.1 2 0.7 3/4 1 92 2.7
3SV 3500 RPM Number of Maximum Motor HP for use Motor HP for use Shutoff Shutoff Stages HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation Draw Motor (1.0 SF) (Feet) (Bar) 16 17.6 20 20 1010 30.2 580 PSI (40 Bar) CCW 14 15 15 15 894 26.7 13 14 15 15 830 24.8 12 12.8 15 15 760 22.7 11 11.5 10 15 700 20.9 10 10.7 10 15 640 19.1 9 9.7 10 10 575 17.2 8 8.5 7.5 10 505 15.1 362 PSI (25 Bar) CW 7 7.5 7.5 7.5 450 13.4 6 6.5 7.5 7.5 380 11.3 5 5.4 5 7.5 320 9.6 4 4.3 5 5 250 7.5 3 3.3 3 5 190 5.7 2 2.2 2 3 128 3.8

4SV 3500 RPM Number of Maximum Motor HP for use Motor HP for use Shutoff Shutoff Stages HP With 1.15 SF With Hydrovar TDH TDH MAWP Motor Rotation Draw Motor (1.0 SF) (Feet) (Bar) 12 26.4 25 NA 930 27.8 580 PSI (40 Bar) CCW 10 21.6 20 25 780 23.3 9 19.2 20 20 700 20.9 8 16.9 15 20 620 18.5 7 14.9 15 15 540 16.1 6 12.9 15 15 460 13.7 362 PSI (25 Bar) CW 5 10.7 10 15 390 11.6 4 8.6 7.5 10 305 9.1 3 6.3 7.5 7.5 228 6.8 2 4.3 5 5 150 4.5

33SV 3500 RPM # of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange # reduced HP with 1.15 SF with Hydrovar TDH TDH Pressure rating Thrust Balancing Rating Diameter Draw Motor (1.0 SF) (Feet) (Bar) (Standard Assy.) Piston 10 54.3 1125 34 10/2 52.8 60 1096 33 10/1 51.3 50 1066 32 9 48.8 1012 30 9/1 47.4 983 29 9/2 45.9 50 954 28 40 Bar (580 PSI) 8 43.4 900 27 8/1 41.9 871 26 Thrust Piston Class 250 / 300 8/2 40.5 40 842 25 Required 7 38 787 23 7/1 36.5 758 23 7/2 35 40 729 22 6 32.6 576 20 6/1 31.1 30 646 19 6/2 29.6 617 18 5 27.1 30 562 17 5/1 25.7 25 533 16 5/2 24.2 25 504 15 4 21.7 450 13 4/1 20.2 20 421 13 4/2 18.8 20 392 12 25 Bar (362 PSI) 3 16.3 337 10 1 3/1 14.7 15 310 9 3/2 13.2 15 281 8 Class 125 / 150 2 10.9 10 225 7 2/1 9.4 10 196 6 2/2 7.9 7.5 167 5 1 5.4 5 7.5 113 3 1/1 4 5 84 3
1 Pump assembly may be modified for 40 bar (580 psi) application – contact factory.

46SV 3500 RPM # of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange # reduced HP with 1.15 SF with Hydrovar TDH TDH Pressure rating Thrust Balancing Rating Diameter Draw Motor (1.0 SF) (Feet) (Bar) (Standard Assy.) Piston 10/2 77.8 1210 36.1 9 73.2 75 1137 33.9 9/1 71.5 1111 33.2 9/2 69.7 75 1085 32.4 8 65 1010 30.2 8/1 63.3 60 984 29.4 8/2 61.6 959 28.6 40 Bar (580 PSI) 7 56.9 884 26.4 7/1 55.2 60 858 25.6 7/2 53.4 50 832 24.8 Thrust Piston Class 250 / 300 6 48.8 758 22.6 Required 6/1 47.1 50 732 21.9 6/2 45.3 706 21.1 5 40.7 40 632 18.9 5/1 38.9 40 605 18.1 5/2 37.2 580 17.3 4 32.5 505 15.1 4/1 30.8 30 30 479 14.3 4/2 29 453 13.5 3 24.4 25 379 11.3 25 Bar (362 PSI) 3/1 22.7 20 25 353 10.5 1 3/2 20.9 327 9.8 2 16.3 20 253 7.6 Class 125 / 150 2/1 14/5 15 15 226 6.7 2/2 12.8 200 6.0 1 8.5 10 10 127 3.8 1/1 6.7 7.5 7.5 102 3.0
# of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sleeve Stages requiring Pump Flange # reduced HP with 1.15 SF with Hydrovar TDH TDH Pressure rating Thrust Balancing Rating Diameter Draw Motor (1.0 SF) (Feet) (Bar) (Standard Assy.) Piston 6 73.2 850 25.4 6/1 70.2 75 75 822 24.5 40 Bar (580 PSI) 6/2 67.2 796 23.8 5 61 60 707 21.1 5/1 58 60 681 20.3 Thrust Piston Class 250 / 300 5/2 55 655 19.6 Required 4 48.8 50 566 16.9 4/1 45.8 50 540 16.1 4/2 42.8 40 513 15.3 3 36.6 40 424 12.7 25 Bar (362 PSI) 3/1 33.6 30 398 11.9 1 3/2 30.6 30 372 11.1 2 24.4 25 25 283 8.4 Class 125 / 150 2/1 21.4 20 257 7.7 2/2 18.4 20 230 6.9 1 12.2 15 15 142 4.2 1/1 9.2 10 10 115 3.4
1 Pump assembly may be modified for 40 bar (580 psi) application – contact factory.

Maximum Inlet Pressure The following table shows the maximum permissible inlet pressure. However, the actual inlet pressure + pressure against a closed valve must always be lower than the maximum permissible operating pressure.
Pump Number of Stages Maximum Inlet Pressure 1SV 2-16 Stages 145 psi (10 bar) 17-22 Stages 215 psi (15 bar) 2SV 2-25 Stages 145 psi (10 bar) 16-22 Stages 215 psi (15 bar) 3SV 2-13 Stages 145 psi (10 bar) 14-16 Stages 215 psi (15 bar) 4SV 2-10 Stages 145 psi (10 bar) 11-12 Stages 215 psi (15 bar) 33SV 1-10 Stages 46SV 1-10 Stages 215 psi (15 bar) 66SV 1-6 Stages 92SV 1-6 Stages


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.)
TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight
6 56C 2 16.63 12.06 20.90 9.87 5.73 7.19 27 51 93 9 3 19.56 13.44 6.70 23.83 30 56 10 5 101 15 182-4TC 5 25.44 15.43 29.71 11.15 6.87 8.50 37 85 137


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.)
TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight
5 56C 2 15.63 12.06 19.90 9.87 5.75 7.19 25 51 91 8 3 18.56 13.88 6.70 22.83 5.50 30 56 10 5 100 13 182-4TC 5 23.50 15.44 27.77 11.15 6.88 8.50 35 85 135 16 26.44 30.71 40 140


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight 2 56C 2 15.75 12.06 20.02 9.87 5.75 7.19 33 51 99 4 182-4TC 3 18.75 15.44 23.02 6.88 8.50 37 85 137 7 7½ 23.25 6.70 27.52 11.15 45 124 10 5 184 9 215TC 10 28.88 15.50 33.15 8.06 10.25 47 151 221 13 254TC 15 33.38 16.56 37.65 9.25 10.83 66 250 339


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight 2 182-4TC 5 15.75 15.44 20.02 6.88 8.50 33 85 133 4 7½ 18.75 6.70 23.02 11.15 39 124 10 5 178 7 254TC 15 24.44 16.56 28.71 9.25 10.31 52 250 325


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight 1/1 182-4TC 5 20.62 15.44 13.95 6.88 8.50 132 85 10 232 1 6.70 12.27 5 2/1 215TC 10 23.58 15.50 16.91 8.06 10.25 143 151 18 317 3/1 254TC 15 26.54 16.56 19.87 9.25 10.31 152 250 425


Frame L2 DI Weights (lb.) Stage (3-Phase)
(max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC Hydrovar Disconnect Total (ref.) End Box Weight 1/1 182-4TC 7½ 22.19 15.44 15.52 6.88 8.50 147 124 10 286 1 215TC 10 15.50 6.70 12.27 8.06 10.25 151 5 313 2/1 254TC 15 25.19 16.56 18.52 9.25 10.31 158 250 18 431

The maximum possible suction head for installation de pends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid.
The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation.
Cavitation is the formation of vapor-filled cavities within liquids where the pressure is locally reduced to a critical value, or where the local pressure is equal to, or just below the vapor pressure of the liquid.
To help the user, with reference to water temperature (40ºF) and to the elevation above sea level, the following tables show the drop in hydraulic pressure head in relation to the elevation above sea level, and the suction loss in relation to temperature.
The vapor-filled cavities flow with the current and when they reach a higher pressure ares the vapor contained in the cavities condenses. The cavities collide, generating pressure waves that are transmitted to the walls. These, being subjected to stress cycles, gradually become de formed and yield due to fatigue. This phenomenon, char acterized by a metallic noise produced by the hammering on the pipe walls, is called incipient cavitation.
Water 68 104 140 176 194 230 248 Temperature (°C)
Suction -.7 2.3 6.6 16.4 24.3 50.5 70.5 Loss (ft)
Elevation Above 1600 3300 4900 6500 8200 9800 Sea Level (ft)
The damage caused by cavitation may be magnified by electrochemical corrosion and a local rise in temperature due to the plastic deformation of the walls. The materials that offer the highest resistance to heat and corrosion are alloy steels, especially austenitic steel. The conditions that trigger cavitation may be assessed by calculating the total net suction head, referred to in technical literature with the acronym NPSH (Net Positive Suction Head).
Suction 1.8 3.6 5.4 7.2 9.0 10.8 Loss (ft)
To reduce it to a minimum, especially in cases of high suc tion head (over 13 – 16 feet) or within the operating limits with high flow rates, we recommend using a suction line having a larger diameter than that of the pump’s suction port. It is always a good idea to position the pump as close as possible to the liquid to be pumped.
The NPSH represents the total energy (expressed in feet) of the liquid measured at suction under conditions of incipi ent cavitation, excluding the vapor pressure (expressed in feet) that the liquid has at the pump inlet.
To find the static height (hz) at which to install the ma chine under safe conditions, the following formula must be verified:
hp + hz ≥ (NPSHr + 2 feet) + hf + hpv where:
hp is the absolute pressure applied to the free liquid sur
face in the suction tank, expressed in feet of liquid; hp is the quotient between the barometric pressure and the specific weight of the liquid.
hz is the suction lift between the pump axis and the free
liquid surface in the suction tank, expressed in feet; hz is negative when the liquid level is lower than the pump axis.
hf is the flow resistance in the suction line and its acces
sories, such as: fittings, foot valve, gate valve, elbows, etc.
temperature, expressed in feet of the liquid. hpv is the quotient between the Pv vapor pressure and the liquid‘s specific weight.
0.5 is the safety factor.

Temp ºF Temp ºC Specific Volume Specific Gravity Weight Vapor Pressure (Cubic ft/lb) @ 39.2ºF @ 60ºF @ 68ºF (lb/cubic ft) (psi Abs) 32 0.0 0.01602 1.000 1.001 1.002 62.42 0.088 35 1.7 0.01602 1.000 1.001 1.002 62.42 0.100 40 4.4 0.01602 1.000 1.001 1.002 62.42 0.122 50 10.0 0.01603 0.999 1.001 1.002 62.38 0.178 60 15.6 0.01604 0.999 1.000 1.001 62.34 0.256 70 21.1 0.01606 0.998 0.999 1.000 62.27 0.363 80 26.7 0.01608 0.996 0.998 0.999 62.19 0.507 90 32.2 0.0161 0.995 0.996 0.997 62.11 0.698 100 37.8 0.01613 0.993 0.994 0.995 62.00 0.949 120 48.9 0.0162 0.989 0.990 0.991 61.73 1.692 140 60.0 0.01629 0.983 0.985 0.986 61.39 2.889 160 71.1 0.01639 0.977 0.979 0.979 61.01 4.741 180 82.2 0.01651 0.970 0.972 0.973 60.57 7.510 200 93.3 0.01663 0.963 0.964 0.966 60.13 11.526 212 100.0 0.01672 0.958 0.959 0.960 59.81 14.696 220 104.4 0.01677 0.955 0.956 0.957 59.63 17.186 240 115.6 0.01692 0.947 0.948 0.949 59.10 24.97 260 126.7 0.01709 0.938 0.939 0.940 58.51 35.43 280 137.8 0.01726 0.928 0.929 0.930 58.00 49.20 300 148.9 0.01745 0.918 0.919 0.920 57.31 67.01 320 160.0 0.01756 0.908 0.909 0.910 56.66 89.66 340 171.1 0.01787 0.896 0.898 0.899 55.96 118.01 360 182.2 0.01811 0.885 0.886 0.887 55.22 153.04 380 193.3 0.01836 0.873 0.874 0.875 54.47 195.77 400 204.4 0.01864 0.859 0.860 0.862 53.65 247.31 420 215.6 0.01894 0.846 0.847 0.848 52.80 308.83 440 226.7 0.01926 0.832 0.833 0.834 51.92 381.59 460 237.8 0.0196 0.817 0.818 0.819 51.02 466.9 480 248.9 0.02 0.801 0.802 0.803 50.00 566.1 500 260.0 0.0204 0.785 0.786 0.787 49.02 680.8 520 271.1 0.0209 0.765 0.766 0.767 47.85 812.4 540 282.2 0.0215 0.746 0.747 0.748 46.51 962.5 560 293.3 0.0221 0.726 0.727 0.728 45.30 1133.1 580 304.4 0.0228 0.703 0.704 0.704 43.90 1325.8 600 315.6 0.0236 0.678 0.679 0.680 42.30 1542.9 620 326.7 0.0247 0.649 0.650 0.650 40.50 1786.6 640 337.8 0.026 0.617 0.618 0.618 38.50 2059.7 660 348.9 0.0278 0.577 0.577 0.578 36.00 2365.4 680 360.0 0.0305 0.525 0.526 0.527 32.80 2708.1 700 371.1 0.0369 0.434 0.435 0.435 27.10 3093.7

Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal. per minute per hour per hour per minute per minute per minute l/min m3/h ft3/h ft3/min Imp. gal/min Us gal./min
1,0000 0,0600 2,1189 0,0353 0,2200 0,2640
16,6670 1,0000 35,3147 0,5886 3,6660 4,4030
0,4720 0,0283 1,0000 0,0167 0,1040 0,1250
28,3170 1,6990 60,0000 1,0000 6,2290 7,4800
4,5460 0,2728 9,6326 0,1605 1,0000 1,2010
3,7850 0,2271 8,0209 0,1337 0,8330 1,0000
0,1100 0,0066 0,2339 0,0039 0,0240 0,0290
Newtons per kilopascal bar Pound force metre millimetre square metre per square inch of water of mercury N/m2 kPa bar psi m H2O mm Hg
1,0000 0,0010 1 x 105 1,45 x 10-4 1,02 x 10-4 0,0075
1000,0000 1,0000 0,0100 0,1450 0,1020 7,5000
100000,0000 100,0000 1,0000 14,5000 10,2000 750,1000
98067,0000 98,0700 0,9810 14,2200 10,0000 735,6000
6895,0000 6,8950 0,0690 1,0000 0,7030 51,7200
2984,0000 2,9840 0,0300 0,4330 0,3050 22,4200
9789,0000 9,7890 0,0980 1,4200 1,0000 73,4200
133,3000 0,1330 0,0013 0,0190 0,0140 1,0000
3386,0000 3,3860 0,0338 0,4910 0,3450 25,4000
millimetre centimetre metre inch foot yard mm cm m in ft yd
1,0000 0,1000 0,0010 0,0394 0,0033 0,0011
10,0000 1,0000 0,0100 0,3937 0,0328 0,0109
1000,0000 100,0000 1,0000 39,3701 3,2808 1,0936
25,4000 2,5400 0,0254 1,0000 0,0833 0,0278
304,8000 30,4800 0,3048 12,0000 1,0000 0,3333
914,4000 91,4400 0,9144 36,0000 3,0000 1,0000
cubic metre litre millilitre imp. gallon US gallon cubic foot m3 litre ml imp. gal. US gal. ft3
1,0000 1000,0000 1 x 106 220,0000 264,2000 35,3147
0,0010 1,0000 1000,0000 0,2200 0,2642 0,0353
1 x 10-6 0,0010 1,0000 2,2 x 10-4 2,642 x 10-4 3,53 x 10-5
0,0045 4,5460 4546,0000 1,0000 1,2010 0,1605
0,0038 3,7850 3785,0000 0,8327 1,0000 0,1337
0,0283 28,3170 28317,0000 6,2288 7,4805 1,0000



ITT 2881 East Bayard Street, Seneca Falls, NY 13148 Phone: (315) 568-7123 • Fax: (315) 568-7973
Goulds Pumps and G&L are registered trademarks of ITT Corporation. ITT, the Engineered Blocks Symbol and Engineered for Life are registered trademarks of ITT Manufacturing Enterprises, Inc.
Copyright © 2009 ITT Corporation BPHV September, 2009 Printed in U.S.A. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.