Laundry Planning Handbook
IHC Washer-Extractors

Refer to Installation manual for full instructions.
5-08-52R1 June 2011




5-08-52 3


1 Ventilation Soap Dispenser 6 Electrical Connections 2 Warm Water Connections .75 in. 7 Ventilation Tub 3 Liquid Soap Connections 8 Drain Valve 4 Soft Water Connections .75 in. 9 Bolt Pattern for Fixation of the Machine 5 Main Switch 10 Hard Water Connections .75 in.
4 5-08-52


5-08-52 5

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
Electrical Installation Requirements - Model IHC012
Table 1 · 6 5-08-52

5-08-52 7


1 Ventilation Soap Dispenser 6 Electrical Connections 2 Warm Water Connections .75 in. 7 Ventilation Tub 3 Liquid Soap Connections 8 Drain Valve 4 Soft Water Connections .75 in. 9 Steam Connections 5 Main Switch 10 Hard Water Connections .75 in
8 5-08-52


5-08-52 9

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
Electrical Installation Requirements - Model IHC018
Table 2 · 10 5-08-52

5-08-52 11


27.16 in. (690 mm) 30.31 in. (770 mm) 32.56 in. (827 mm)
31.14 in. (791 mm) 29.41 in. (747 mm) 19.1 in. (485 mm)
1 Ventilation Soap Dispenser 6 Electrical Connections 2 Warm Water Connections .75 in. 7 Ventilation Tub 3 Liquid Soap Connections 8 Drain Valve 4 Soft Water Connections .75 in. 9 Steam Connections 5 Main Switch 10 Hard Water Connections .75 in
12 5-08-52


5-08-52 13

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
Electrical Installation Requirements - Model IHC025
Boiler Fed/Steam Heat Electric Heat
kW Standard Heating Elements
Recommended Circuit Breaker (US-market)
Recommended Circuit Breaker (US-market)
N 440-480 50/60 3 3+PE 4 10 10 14/2.5
P 380-415 50/60 3 3+N+PE 12 15 16 14/2.5 21 30 25 10/6.0
Q 200-240 50/60 3 3+PE 12 15 16 14/2.5 27 30 32 10/6.0
X 200-240 50/60 1/3 2/3+PE 12 15 16 14/2.5 N/A
Alternative Electric Heat Options
N/A N/A N/A N/A
P 380-415 50/60 3 3+N+PE 18 20 20 12/4.0
3x1.4 kW
Q 200-240 50/60 3 3+PE 23 30 25 10/6.0
X 200-240 50/60 1/3 2/3+PE N/A
N/A N/A N/A N/A
P 380-415 50/60 3 3+N+PE 25 30 32 10/6.0
Q 200-240 50/60 3 3+PE 35 40 40 8/10.0
X 200-240 50/60 1/3 2/3+PE N/A
21 30 25 10/6.0
P 380-415 50/60 3 3+N+PE 29 40 32 8/10.0
Q 200-240 50/60 3 3+PE N/A
X 200-240 50/60 1/3 2/3+PE N/A

Capacity (dry weight) Ratio (kg/l)
1:11 26.46 lb. (12 kg)
1:10 29.10 lb. (13.2 kg)
1:9 31.97 lb. (14.5 kg)
Cylinder diameter, in. (mm) 25.59 (650)
Cylinder depth, in. (mm) 15.75 (400)
Cylinder volume, ft.3 (l) 4.66 (132)
Overall height, in. (mm) 47.32 (1202)
Overall width, in. (mm) 30.71 (780)
Overall depth, in. (mm) 33.15 (842)
Door opening size, in. (mm) 11.81 (300)
Height of door bottom above floor, in (mm) 14.78 (376)
Height of door center above floor, in (mm) 23.82 (605)
Wash 10-50 tr/min - RPM
Distribution 85 tr/min - RPM
Spin 250-1000 tr/min - RPM
Motor (3 phase), 4p, 1470 tr/min 2.01 HP/1.5 kW
Drain Valve, in. (mm) 2 (51)
Water Supply (hard, soft, warm water), in. (mm).75 (19)
Steam inlet connection size, in. (mm) .38 (10)
Electrical Heating (230/400 V) 12 kW - 15 kW - 18 kW
Electrical Heating (400V) 21 kW - 24 kW
Warm Water (without additional heating) Not Applicable
Warm Water (with additional heating) Not Applicable
Packing Dimensions (height X width X depth), in. (mm) 51.57 X 33.46 X 37.01 (1310 X 850 X 940)
Net weight, lb. (kg) 716.50 (325)
Gross weight, lb. (kg) 782.64 (355)


26.18 in. (665 mm) 29.92 in. (760 mm) 32.13 in. (816 mm)
1 Ventilation Soap Dispenser 6 Electrical Connections 2 Warm Water Connections .75 in. 7 Ventilation Tub 3 Hard Water Connections .75 in 8 Drain Valve 4 Soft Water Connections .75 in. 9 Steam Connections 5 Main Switch 10 Liquid Soap Connections
16 5-08-52


5-08-52 17

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
Electrical Installation Requirements - Model IHC030
Boiler Fed/Steam Heat Electric Heat
kW Standard Heating Elements
Recommended Circuit Breaker (US-market)
Recommended Circuit Breaker (US-market)
N 440-480 50/60 3 3+PE 6 15 10 14/2.5
23 30 32 10/6.0
P 380-415 50/60 3 3+N+PE 18 20 20 12/4.0 36 40 40 8/10.0
Q 200-240 50/60 3 3+PE 18 20 20 12/4.0 49 60 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 18 20 20 12/4.0 N/A
Alternative Electric Heat Options
28 40 40 8/10.0
3x3 kW + 3x2 kW
P 380-415 50/60 3 3+N+PE 40 50 50 8/10.0
Q 200-240 50/60 3 3+PE 56 60 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 56 60 60 6/16.0
32 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 44 50 50 8/10.0
Q 200-240 50/60 3 3+PE 63 70 70 4/25.00
X 200-240 50/60 1/3 2/3+PE 63 70 70 4/25.00
36 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 49 60 60 6/16.0
3x3 kW + 3x4 kW
Q 200-240 50/60 3 3+PE N/A
X 200-240 50/60 1/3 2/3+PE N/A
41 50 50 8/10.0
P 380-415 50/60 3 3+N+PE 53 60 60 6/16.0
Q 200-240 50/60 3 3+PE N/A
X 200-240 50/60 1/3 2/3+PE N/A

Capacity (dry weight) Ratio (kg/l)
1:11 33.07 lb. (15 kg)
1:10 36.38 lb. (16.5 kg)
1:9 40.34 lb. (18.3 kg)
Cylinder diameter, in. (mm) 25.59 (650)
Cylinder depth, in. (mm) 19.69 (500)
Cylinder volume, ft.3 (l) 5.83 (165)
Overall height, in. (mm) 47.32 (1202)
Overall width, in. (mm) 30.71 (780)
Overall depth, in. (mm) 37.09 (942)
Door opening size, in. (mm) 11.81 (300)
Height of door bottom above floor, in (mm) 14.78 (376)
Height of door center above floor, in (mm) 23.82 (605)
Wash 10-50 tr/min - RPM
Distribution 85 tr/min - RPM
Spin 250-1000 tr/min - RPM
Motor (3 phase), 4p, 1470 tr/min 2.01 HP/1.5 kW
Drain Valve, in. (mm) 2 (51)
Water Supply (hard, soft, warm water), in. (mm).75 (19)
Steam inlet connection size, in. (mm) .38 (10)
Electrical Heating (230/400 V) 12 kW - 15 kW - 18 kW
Electrical Heating (400V) 21 kW - 24 kW
Warm Water (without additional heating) Not Applicable
Warm Water (with additional heating) Not Applicable
Packing Dimensions (height X width X depth), in. (mm) 51.57 X 33.46 X 42.52 (1310 X 850 X 1080)
Net weight, lb. (kg) 789.25 (358)
Gross weight, lb. (kg) 855.39 (388)


1 Ventilation Soap Dispenser 6 Electrical Connections 2 Warm Water Connections .75 in. 7 Drain Valve 3 Soft Water Connections .75 in. 8 Steam Connections 4 Ventilation Tub 9 Hard Water Connections .75 in. 5 Main Switch 10 Liquid Soap Connections
20 5-08-52


5-08-52 21

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
Electrical Installation Requirements - Model IHC035
Boiler Fed/Steam Heat Electric Heat
kW Standard Heating Elements
Recommended Circuit Breaker (US-market)
Recommended Circuit Breaker (US-market)
N 440-480 50/60 3 3+PE 6 15 10 14/2.5
32 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 18 20 20 12/4.0 44 50 50 8/10.0
Q 200-240 50/60 3 3+PE 18 20 20 12/4.0 63 70 70 4/25.0
X 200-240 50/60 1/3 2/3+PE 18 20 20 12/4.0 63 70 70 4/25.0
Alternative Electric Heat Options
23 30 32 10/6.0
P 380-415 50/60 3 3+N+PE 36 40 40 8/10.0
Q 200-240 50/60 3 3+PE 49 60 60 6/16.0
X 200-240 50/60 1/3 2/3+PE N/A
28 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 40 50 50 8/10.0
3x3 kW + 3x2 kW
Q 200-240 50/60 3 3+PE 56 60 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 56 60 60 6/16.0
36 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 49 60 60 6/16.0
3x3 kW + 3x4 kW
Q 200-240 50/60 3 3+PE N/A
X 200-240 50/60 1/3 2/3+PE N/A
41 50 50 8/10.0
P 380-415 50/60 3 3+N+PE 53 60 60 6/16.0
Q 200-240 50/60 3 3+PE N/A
X 200-240 50/60 1/3 2/3+PE N/A


Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
The machine must be securely fixed on a flat surface (metal base, concrete or solid ground). The anchoring is to be done on the 6 provided places in the holes on the corner of the base. (See Mounting Bolt Hole Locations). Refer to Figure 12.

The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 23.62 in. (600 mm) between the wall and the back of the machine.
If several machines are placed next to each other, there should be a minimal distance of 1.18 in. (30 mm) between each machine.
5-08-52 23