Manuel d'utilisation / d'entretien du produit SR1450 du fabricant Intel
Aller à la page of 87
Intel® Server Chassis SR1450 User Guide Order Number: C95452-002.
Disclaimer Information in this document is provided in connection with Intel ® products. No license, express or implied, by esto ppel or otherwise, to any intellectual property rights i s granted by this document.
Intel ® Server Chassis SR1450 User Guide iii Preface About this Manual Thank you for purchasing and usi ng the Intel® Server Chassis SR1450. This manual is written for system technicians w ho are responsible for tr oubleshooting, upgrading, and repairing this server chassis.
Preface iv Product Contents, Order Options, and Accessories The server chassis SR1450 is compatible w ith the Intel® Server Board SE7520JR2. Your Server Chassis SR1450 ships with the following items:.
Preface Intel ® Server Chassis SR1450 User Guide v You must choose from several required op tions when purchasing this chassis: Riser option, choose one: • Full-height PCI-X riser • Full-heig.
Preface vi Additional Information and Software If you need more information about this product or inf ormation about the accessories that can be used with this server board, use the following resources. These sources are available at http://support.intel.
Preface Intel ® Server Chassis SR1450 User Guide vii Safety Informa tion WARNING Before working with your server product, whet her you are using this guide or any other resource as a reference, pay close attention to th e safety instructions.
Preface viii Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure th e AC power cord is unplugged before you open the chassis, add, or remove any components .
Preface Intel ® Server Chassis SR1450 User Guide ix Safety Cautions Read all caution and safety statements in this document before performing a ny of the instructions. See also Intel Server Boards and Server Chassis Safety Information or at http://support.
Intel ® Server Chassis SR1450 User Guide x Contents Warnings ....................................................................................................... viii 1 Server Chassi s Featur es ....................................................
Contents Intel ® Server Chassis SR1450 User Guide xi Installing a PCI Add-in Card ......................................................................................... 47 Removing a PCI Add-in Card ................................................
Contents xii Extent of Limited Warranty .................................................................................................... 8 5 Warranty Limitations and Exclusions ......................................................................
Contents Intel ® Server Chassis SR1450 User Guide xiii Figure 41. Removing the Power Supply Air Duct ....................................................................... 56 Figure 42. Removing a Power Supply Fan Module ............................
Intel ® Server Chassis SR1450 User Guide 14 1 Server Chassis Features This chapter briefly describes the main features of Intel ® Server Chassis SR1450. This chapter provides drawings of the product, a list of the serv er features, and diagrams showing the location of important components and connections on the server chassis.
Server Chassis Features Intel® Server Chassis SR1450 User Guide 15 Table 1 summarizes the major features of the server chassis. 4 Table 1. Server Chassis Features Feature Description Dimensions 1.
Server Chassis Features 16 Table 1. Server Chassis Features (continued ) Power Supply One hot-swap 520W power supply m odule One plus one hot-swap redundant 520W power supply (optional access .
Server Chassis Features Intel® Server Chassis SR1450 User Guide 17 Component Identification Internal Components The diagram below shows the server chassis with a server board installed into it. TP01585 C A L M K J I H D B G E F A. Single system PCI fan H.
Server Chassis Features 18 Standard Control Panel The diagram below shows the features available on the Standard Control Panel. The Standard Control Panel is one of two require d front panel option s that can be selected. The other option is the Intel® Local Control Panel.
Server Chassis Features Intel® Server Chassis SR1450 User Guide 19 Intel ® Local Control Panel The diagram below shows the features available on the Intel ® Local Control Panel. The Intel Local Control Panel is one of two require d front panel option s that can be selected.
Server Chassis Features 20 Callout Feature Function J System Status LED Solid gree n indicates normal operati on. Blinking green indic ates degraded performance. Solid amber indicates a critical or no n-recoverable condition. Blinking amber indicat es a non-critical condition.
Server Chassis Features Intel® Server Chassis SR1450 User Guide 21 Peripheral Devices (Front Features) The chassis provides locations and hardware for installing hard drives, a floppy drive, CD-ROM drive, or DVD-ROM drive. The drives must be purchased separately.
Server Chassis Features 22 Floppy / CD-ROM / DVD-ROM Slimline Carriers The slimline drive carriers can be used with one slimline floppy, CD-ROM or DVD-ROM drive. There are two carriers that ship with the chassis; one carrier is for a CD-ROM or DVD-ROM, and the other is for a slimline floppy.
Server Chassis Features Intel® Server Chassis SR1450 User Guide 23 Rack-Mounted Systems Your Intel ® Server Chassis SR1450 is designed to be mounted into a rack. You must choose from one of two accessories. The Intel Server Chassis SR1450 comes ready for mounting using the Tool-less Rail Kit (AXXHERAIL).
Intel ® Server Chassis SR1450 User Guide 24 2 Har d ware Installations and Upgrades Before You Begin Before working with your server product, pay clos e attention to the safety instructions at the beginning of this manual. See “Safety Information.” This document provides instructions for adding an d replacing chassis components.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 25 Removing and Installing the Chassis Cover Removing the Chassis Cover The Server Chassis SR1450 must be operated with th e top cover in place to ensure proper cooling. You will need to remove the top cover to add or replace components inside of the platform.
Hardware Installa tions and Upgrades 26 Installing the Chassis Cover 1. Place the cover over the chassis so that the side edges of the cover sit just inside the chassis sidewalls. 2. Slide the cover forward until it clicks into place. See letter “A” in the figure below.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 27 Removing and Installing the Front Bezel The front bezels are available as optional accessories for the Server Chassis SR1450.
Hardware Installa tions and Upgrades 28 Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the front bezel for the Intel Local Control Panel. The front bezel is optional. 1. At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 29 Removing the Processor Air Duct 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades 30 TP01597 Figure 14. Preparing the Processor Air Duct 5. Place the processor air duct over the processor socket(s). See the figure below. The front edge of the air duct should contact the fan module and th e top of the installed air duct should be flush with the top surface of the fan module.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 31 Installing and Removing a Hard Disk Drive Up to three hard drives of one of the following types can be installed, depending on t he hard drive installation option used in your server chassis and the drives supported by y our server board.
Hardware Installa tions and Upgrades 32 4. Remove the four screws that attach the plastic baffle or the previously installed hard drive to the drive carrier. Two screws are at each side of the baffle or the hard drive. If required, store the plastic baffle for future use.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 33 6. When the black drive carrier lever begins to close by itself, push on it to lock t he drive assembly into place. TP01602 B A Figure 19. Inserting a Hot-swap Hard Disk Drive Ass embly into the Chassis 7.
Hardware Installa tions and Upgrades 34 Installing a Floppy Drive into Slimline Bay Use these instructions if you are installing a floppy drive into the slimline drive bay at the uppe r left side of your chassis.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 35 7. Open the connector on the rear of the floppy dr ive by pulling up on the connector cover. See letter “A” in the figure below. 8. Insert one end of the 26-pin floppy drive flat fl ex cable end into the connector.
Hardware Installa tions and Upgrades 36 13. Connect the floppy drive data cable that was included with your kit between the interposer board and the server board. See letters “B” a nd “C” in the figure. See your server board documentation for assistance in locating the connector location on the server board.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 37 14. Install the chassis cover. For instructions, see “ Installing the Chassis Cover .” 15. (Optional) Install the front bezel. For instructions, see “ Removing and Installing the Front Bezel .
Hardware Installa tions and Upgrades 38 7. Slide the floppy drive into the drive carrier, rear of the drive first, with the underside of the drive facing down. 8. Line up the holes in the side of the drive with the holes in the carrier. See letter “A” in the figure below.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 39 10. Reattach the slide rails onto floppy drive conversion kit carrier. See the figure below. TP01309 Figure 27. Install the Rails onto the Floppy Drive Conversion Kit Carrier 11.
Hardware Installa tions and Upgrades 40 14. Attach the other end of the flat flex cable to the interposer board. 15. Install the interposer board into the floppy driv e conversion kit carrier. One screw attaches on the right side. 16. Slide the carrier assembly into center ha rd drive bay until it clicks into place.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 41 Installing or Removing a CD-ROM or DVD-ROM Drive CAUTION CD-ROM and DVD-ROM drives are NOT hot swappable.
Hardware Installa tions and Upgrades 42 9. Slide the DVD-ROM / CD-ROM drive carrier into the chassis. See letter “A” in the figure below. 10. Attach the 44-pin CD-ROM drive cable to the expos ed side / back of the interpo ser board. See letter “B” in the figure below.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 43 Removing a CD-ROM or DVD-ROM Driv e from the Slimline Bay 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades 44 Installing a PCI Riser Card To install the PCI riser card, use the following instructions. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 45 6. Line up the stand-offs on the riser assembly with the slot and the large hole on t he riser card. 7. Press and hold the blue riser locking lever. See letter “A” in the figure below.
Hardware Installa tions and Upgrades 46 Removing a PCI Riser Card The PCI riser card can be replaced if it fails or if a different option is required. To replace the PCI riser card, use the following instructions to rem ove it, and then foll ow the instructions under “Installing a PCI Riser Card” to install a new riser card.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 47 Installing and Removing a PCI Add-in Card Installing a PCI Add-in Card In the slot provided by the PCI riser card, you can install one add-in card. Use the following instructions to install an add-in card.
Hardware Installa tions and Upgrades 48 6. Open the PCI retention clip on the PCI riser car d assembly. See letter “A ” in the figure below. 7. Remove the filler panel at the back of the rise r assembly. See letter “B” in the figure below. 8. Insert the add-in card until it seats in riser card connector.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 49 Removing a PCI Add-in Card 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades 50 Replacing the Standard Control Panel Your server must be operated with a control pane l installed. The steps for replacing the Standard Control Panel are listed below. CAUTION The control panel is NOT hot swappable.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 51 Replacing the Intel ® Local Control Panel Your server must be operated with a control panel installed. The st eps for replacing the Intel Local Control Panel are listed below.
Hardware Installa tions and Upgrades 52 8. If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using th e opt ional bezel, make sure the back half of the tray is secured in the “shortened” position.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 53 Replacing System Fan(s) The system fans at the front of the Server Cha ssis SR1450 can be individually replaced if one of them fails. Use the steps below to replace a dual rotor fan.
Hardware Installa tions and Upgrades 54 8. Note the position of the raised arrows in the top of the replacement fan. Position t he fan so one arrow points to the left, and the other arrow point s to the rear of the chassis. The fan cable should be pointing to the re ar of the chassis.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 55 TP01626 A B Figure 40. Removing the Single System PCI Fan 6. Note the position of the raised arrows in the top of the replacement fan. Position t he fan so one arrow points to the left, and the other arrow point s to the rear of the chassis.
Hardware Installa tions and Upgrades 56 Removing the Power Supply Air Duct Use the steps below to remove the power supply air duct. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 57 Replacing a Power Supply Fan Module The power supply fan modules in the Server Cha ssis SR1450 can be individually replaced if one of them fails. Use the steps below to replace a dual rotor fan.
Hardware Installa tions and Upgrades 58 Replacing the Power Distribution Board The power distribution board is located between the two power supplies. This b oard can be replaced if it fails. To replace the power distri bution board, use the following instructions.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 59 TP01629 L K H G G F J I A C B E K D Q P Figure 43. Removing the Power Distribution Board 15. Line up the holes on the replacement power distri bution board with the power supply stand-offs on chassis.
Hardware Installa tions and Upgrades 60 23. If a slimline DVD/CD-ROM or floppy drive is installed, connect power (see letter “J” in “Figure 44” ) and data cable (see letter “K” in “Figure 44” ). 24. Connect the PCI fan. See letter “L” in “Figure 44”.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 61 Replacing the Hot-Swap Power Supply The power supply can be replaced if it fails.
Hardware Installa tions and Upgrades 62 TP01630 B A Figure 46. Removing the Rear Hot-Swap Power Supply from the Chassis Installing a Hot-Swap Power Supply To install a replacement power supply or to a dd a redundant power supply, use the following instructions.
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 63 Removing and Installing the SATA or SCSI Backplane Your server chassis must be configured with one of the following drive installation options: A hot-swap SCSI option that came with a SCSI backplane board.
Hardware Installa tions and Upgrades 64 Removing the SATA or SCSI Backplane 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades Intel ® Server Chassis SR1450 User Guide 65 Installing the SATA or SCSI Backplane 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.” 2. Power down the server and unplug all periphe ral devices and the AC power cable(s).
Hardware Installa tions and Upgrades 66 8. Connect the following cables to the backplane: Front panel cable Power cable (SCSI backplane only): SCSI Channel A cable. Th e cable indicates the end that is to be connected to the backplane. (SATA backplane only): SATA cable(s).
Intel ® Server Chassis SR1450 User Guide 67 T echnical Ref erence Cable Routing When you add or remove components from your serv er chassis, make sure your cables are routed correctly before reinstalling the chassis cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked.
Technical Reference 68 TP01612 B C D A E Figure 50. SATA Cable Routing Thr ough Notches in Metal Air Baffle Table 3. SATA Cable Routing Reference A SATA0 cable B USB cable (front panel to server board.
Technical Reference Intel ® Server Chassis SR1450 User Guide 69 Power Supply Specifications 520-W Single Power Supply Input Voltages 100-127 V ∼ at 50/60 Hz; 6.
Technical Reference 70 System Environmental Specifications Table 5. Environmental Specifications Temperature Non-operating Operating –40 ° to 70 °C. +10 ° C to +35 ° C with the maximum rate of change not to exceed 10 ° C per hour Humidity Non-operating 90% relative humidity (non-condensing) at 35 °C.
Intel ® Server Chassis SR1450 User Guide 71 Equipment Log and W orksheets Equipment Log Use this equipment log to record information about your server.
Equipment Log and Worksheets 72 Current Usage Calculating Power Usage The total combined wattage for your configuration must be less than the wattage rating for your power supply. Use the worksheets in this section to calcula te the total used by your configuration.
Equipment Log and Worksheets Intel ® Server Chassis SR1450 User Guide 73 Worksheet, Total Combined Power Used by the Server 1. From the previous worksheet, enter the total current for each column. 2. Multiply the voltage by the total current to ge t the total wattage for each voltage level.
Intel ® Server Chassis SR1450 User Guide 74 Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Server Chassis SR1450 complies with the following safety .
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 75 Certifications / Registrations / Declarations UL Certification (US/Canada) CE Declaration of Conformity (CENE.
Regulatory and Compliance Information 76 Table 8. Product Certification Markings (co ntinued) Regulatory Compliance Country Marking BSMI Certification Number & Class A Warning Taiwan GOST R Markin.
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 77 This equipment has been tested and found to comp ly with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These lim its are designed to provide reasonable protection against harmful interference in a residential insta llation.
Regulatory and Compliance Information 78 VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment.
Regulatory and Compliance Information Intel ® Server Chassis SR1450 User Guide 79 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to.
Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SR1450 Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card e x ch an g e r at e p l u s ap p l i ca bl e t ax es .
Intel Server Issue Report Form Intel ® Server Chassis SR1450 User Guide Intel ® Server Issue Repor t Form Date Submitted: Company Name: Contact Name: Email Address: Intel Server Product: Priority (Critical, Hot, High, Low): Brief Problem Description.
Operating System Information Operating System Version Service Pack # Peripheral Information Check each box below that is used, a nd provide the requested information Peripheral Card Or Periphe ral Des.
Intel Server Issue Report Form Intel ® Server Chassis SR1450 User Guide Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found.
.
Intel ® Server Chassis SR1450 User Guide 85 W arranty Limited Warranty for Intel ® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel ® chassis subassembly a.
Warranty Warranty Limitations and Exclusions These warranties replace al l other warra nties, expr essed or implied including, but not limited to, the implied warranties of merchantability and fitness fo r a particular purpose. Intel makes no expressed warranties beyond those stated here.
Warranty Intel ® Server Chassis SR1450 User Guide 87 How to Obtain Warranty Service To obtain warranty service for this Product, you ma y contact Intel or your authorized distributor. North America and Latin America To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Intel SR1450 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Intel SR1450 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Intel SR1450, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Intel SR1450 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Intel SR1450, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Intel SR1450.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Intel SR1450. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Intel SR1450 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.