McBasic TP/FO & TP/BNC Operation Manual.
ii FCC Radio Frequency Inter ference Statem ent This equipment has been tested and found t o comply with the limits for a Class B computing device, pur suant to Part 15 of the F CC Rul es. These limits are designed to provid e reasonable protection against harmful interference when the equipment is operated in a com mercial environment.
iii Table of Cont ents FCC Radio Fre quency Interfe rence Statemen t .................................................... ii Warranty ............................. ................................................................. .............. ii About the McBasic .
iv Notes.
1 Abou t the McBa sic The McBasic series consists of low-cost, IEEE 8 02.3 singl e-conversion, 1U high, standalone media conve rters. The McBasic TP/FO con verts 10Base-T twisted pair to 10Base-FL multi-mo de or single-m ode fi ber and includes one RJ- 45 connector and one pai r of S T o r SC connect ors.
2 BNC Port Termina tion McBasi c TP/BNC features a 2-position switch next to the BNC connector that a llows a thin coax ial segment to be terminated at th e port w ithout a n additional ‘ T’ connector and termin ator. If McBasic TP/B NC is attached to a mid-p oint of a th in Et her n et segment, attach a ‘T’ connect or to th e BNC port.
3 About Link Integrity During normal operation, link integrity pu lses are transmitted by all point-to-point Ethernet devices. When an IM C Networks media converter rece ives valid link pulse s, it knows that the device to which it is co nnec ted is up and sending pulses, an d that the copp er or fiber c able coming f rom that device is intact.
4 Pulsing Fiber Alert Pulsing FiberAle rt minimizes t he problems as sociated with the l oss of one strand of fiber. If a strand is unavaila ble, the IMC Netwo rks device at the receiver end notes the loss of link. The device will stop transmitting data and start sending link pulses.
5 LED Operation Each McBasic fe atures diagnostic LE Ds. The following illustrations show the location of the LED s, an d othe r fe atu re s, on McBasic TP /FO and McBas ic TP/BNC. The LED fun ctio ns f or McBa sic TP/FO are as fol lows: • TP LINK Glows green if li nk is established on the TX port.
6 The LED fun ctio ns for M cBasic TP/ BNC are as f ollow s: • TP RCV Flickers amber when twisted p air port is receiv ing data . • TP LNK Glows green when a twisted pair link is established. • BNC COL Flickers re d in normal o peration indicat ing norm al collisions are bein g detecte d on the BNC segment.
7 Installat ion Tro ubles hoot ing • During installation, first test your fiber and t wisted pair c onnections with all troubleshooting features disabled. Then enable these features, if desired, just before final inst allation. This wil l reduce the in terference fr om feature s upon testing .
8 IMC Networks Technical Suppor t Tel: (949) 465-3000 or (800 ) 624-1 070 (in the U.S. and Cana da); +32-16-550 880 (Europe) Fax: (9 49) 465-3 020 E-Mail: techsuppor t@im cnetwork s.com Web: ww w.imcnetwor ks.com Spec if icat io ns Power AC Input Load: 100/240V±10 % ~ 50/60 Hz, 0.
9 Dimensions: McBasic TP/ FO 1.68”H x 4.75 ”W x 4 .95”D (4 .3 cm x 12.1 cm x 12.6 cm) McBasi c TP/BNC 1.68"H x 4.7 5"W x 4 .53"D (4.
10 Fiber Op tic Cleaning Guidelines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt or dust, which can obst ruct the optic path and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules.
11 Safety Certif ications UL/CUL: Listed to Safety of Informati on Technology Equipm ent, including Electrical Business Equipment. CE: The products described herein comply with the Council Directive o.
19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (949 ) 465-3 020 www.imcnetworks.com © 2008 I MC Networks. Al l rights r eserved. The info rmation in this docum ent is subject to change with out no tice. I MC Networks assumes no responsibili ty for an y errors that may appear in this document.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté IMC Networks SP50 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du IMC Networks SP50 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation IMC Networks SP50, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le IMC Networks SP50 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le IMC Networks SP50, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du IMC Networks SP50.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le IMC Networks SP50. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei IMC Networks SP50 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.