1 Model 43168 Owners Manual HEA T PUMP PROGRAMMABLE THERMOST A T PM COOL TEM P 3 SA Form 44014-01 r010408.
2 3 Congratulations! Thank you for choosing a Climate T echnology Corporation (CTC) programmable thermostat. Y our new CTC thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions.
4 5 1.This thermostat is designed to work on the following systems: • Single-Stage Heat Pump • Mulit-stage Heat Pump (up to 2 heating and 2 cooling) 2.T emperature Range This thermostat can be set between 45°F and 95°F (7°C and 35°C).However , it will display room temperatures from 30°F to 99°F (0°C and 37°C).
6 7 Wire Labeling • CAUTION! TURN OFF POWER TO THE HEA T PUMP SYSTEM BEFORE YOU A TTEMPT TO ACCESS THE THERMOST A T’S WIRING. • IMPORT ANT! BEFORE DISCONNECTING ANY WIRES FROM THE EXISTING THERMOST A T , APPL Y THE PROVIDED SELF-ADHESIVE LABELS TO THE WIRES.
8 9 Mount Wallplate • Remove the wallplate from the thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. Figure 2 • Positionwallplateonwall andpullexisting wiresthroughthelarge opening,thenlevelfor appearance.
10 11 ON O N 1 2 HE HG F C Connect Wires and Mount Thermostat to W allplate • Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. See Figure 4. Ignore any wires which may be present, but which were not connected to the old thermostat.
12 13 THERMOST A T CONTROLS • Open the thermostat’s front cover . See Figure 6. Figure 6 • Insertthetabsontopofthethermostatbodyintotheslotsatthetopofthewallplate.Pressthebottomof the thermostat body into the snap on the bottom of the wallplate.
14 15 system off cool heat fan auto refresh on reset hold/rtrn em heat sys em aux lter program day/time A B C D E I J K Switches and Buttons Switches and Buttons A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump system’s operation and status.
16 17 The default for this thermostat setting is in a 12 hour format. Y ou can change the format to 24 hour format by pressing D a y /T i m e and then P r o g r a m . The AM/PM indicator will be off when the thermostat is in 24 hour mode. Settingdayandtime: 1.
18 19 This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operation instructions, see pages 21-23. T o utilize the pre-programmed settings, see pages 24-25. T o create custom programs, see pages 26-29.
20 21 1. MANUAL OPERA TION Many people prefer to operate their thermostats manually , adjusting settings as needed. Y ou can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually .
22 23 MANUAL OPERA TION, CONT . Ifyouwanttopermanentlyoverrideallsettingsandadjustthethermostatmanually: 1. Press H o l D /r e T U r n until the Hold icon appears. 2. Press and hold U P or D o w n for one second to enter Manual Override mode.
24 25 2. DEF AUL T PROGRAMS ThisthermostatmeetsENERGYST ARguidelinesforenergyefciency .Byusingthepre- programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling.
26 27 system off cool heat hold/rtrn em heat program Methods of Operation (cont.) AM PM H o l D /r e T U r n P r o g r a m U P and D o w n buttons s y s T e m switch AM/PM indicator 3. CREA TING CUSTOM PROGRAMS NOTES: • Programtimescanbesetin10minuteincrements.
28 29 Methods of Operation (cont.) system off cool heat em heat program AM HE AT PM COOL 4 3 2 1 M T W TH F SA SU 3. Press U P or D o w n to change the hour . Press P r o g r a m to save the hour and adjust the minute setting. 4. Press U P or D o w n to change the minute.
30 31 1. INDIGLO ® night-light - will backlight the display for easy viewing in the dark. Press any button to illuminate the light. 2. Filterchangeindicator-willashafter400hoursofsystemuseasaremindertocheckor changeyourlter .
32 33 6. Error mode – if the thermostat is unable to control your system due to an unexpected problem,thethermostatwillenterErrorMode.Inthiscondition,thethermostatashes“E1”, “E2”, or “E3” on the LCD display , and shuts off your system.
34 35 1. T emperature Range 2. Compressor Protection After the system stops running, there will be a 3.5 minute delay before it can be restarted to prevent compressor damage due to rapid cycling. 3. Resetting the unit T o restore the thermostat to the original factory settings, press the reset button with a paperclip.
36 37 Setting Options ThefollowingOptionsareavailableonyourthermostat: 1. 1st stage span - The factory setting for Stage 1 heating and cooling is 1, meaning that your thermostat will cycle at 1°F (0.5°C) above and below the set temperature in Stage 1.
38 39 TROUBLESHOOTING Problem Solution 1. Check wiring connections. A Common (C) wire is required for operation. 2. Press and hold the Reset button for two seconds with the tip of a paper clip. LCD Display is blank Auto/Fan does not turn on in Heat Mode 1.
40 41 WIRING DIAGRAM.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hunter Fan 43168 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hunter Fan 43168 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hunter Fan 43168, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hunter Fan 43168 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hunter Fan 43168, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hunter Fan 43168.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hunter Fan 43168. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hunter Fan 43168 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.