Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Model KML-700MWH-M Low-Profile Modular Crescent Cuber Hoshizaki America, Inc. Issued: 10-13-2009 I N S T R U C T I O N M A N U A L .
IMPORTANT Only qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
3 CONTENTS Important Safety Information ................................................................................................. 4 I. Specications ............................................................................................
4 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury.
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1. KML-700MWH-M (water-cooled marine) See the nameplate for electrical and refrigeration specications.
6 B. Dimensions/Connections 1. KML-700MWH-M (water-cooled marine) Unit: in. (mm).
7 II. Installation and Operating Instructions WARNING 1. This icemaker must be installed in accordance with applicable international, national, state, and local regulations. . CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation.
8 C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
9 E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet international, national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, re, or severe damage to equipment.
10 F. Water Supply and Drain Connections See Fig. 4 or 5 WARNING 1. Water supply and drain connections must be installed in accordance with applicable international, national, state, and local regulations. . Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
11 Fig. 4 KML-700MWH-M Connection to an Open Drain System 2. Water-Cooled Condenser a) Connection to an Open Drain System • Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
1 Condenser Return Line Shut-Off Valve Condenser Return Line Drain Valve Icemaker Drain Outlet 3/4" FPT Icemaker Water Supply Inlet 1/" FPT Fig. 5 Condenser Water Supply Inlet 1/" FPT Condenser Return Outlet 3/8" FPT Separate piping to approved drain.
13 G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/storage bin.
14 H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. . If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
15 III. Cleaning and Maintenance WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the dispenser unit/storage bin.
16 8) In bad or severe water conditions, clean the oat switch assembly as described below. Otherwise, continue to step 9. a. Remove the 3 screws securing the oat switch assembly, then remove the assembly. b. Remove the retainer rod from the bottom of the oat switch housing, then remove the oat.
17 2. Sanitizing Procedure - Following Cleaning Procedure 1) Dilute 1.5 . oz. (37 ml or .5 tbs) of a 5.5% sodium hypochlorite solution (chlorine bleach) with .5 gal. (9.5 l) of warm water. ) Remove the front insulation panel. 3) Pour the sanitizing solution into the water tank.
18 C. Preparing the Icemaker for Long Storage CAUTION 1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage.
19 3) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve. 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.
0 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1HL10A.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hoshizaki KML-700MWH-M c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hoshizaki KML-700MWH-M - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hoshizaki KML-700MWH-M, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hoshizaki KML-700MWH-M va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hoshizaki KML-700MWH-M, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hoshizaki KML-700MWH-M.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hoshizaki KML-700MWH-M. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hoshizaki KML-700MWH-M ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.