Manuel d'utilisation / d'entretien du produit ESC-42ST du fabricant Heat & Glo LifeStyle
Aller à la page of 68
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 1 Model: ESC-42ST • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Seri.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 4 = Contains updated information. 14 Appliance Setup A. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 B. Remove the Shipping Materials . . . . . . . . . . . .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 7 C. BTU Speci fi cations MODELS: ESC-42ST , ESC-42STLP LABORA TOR Y : Underwriters Laboratories, Inc.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 10 C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 1 1 I. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a quali fi ed service technician : • V erify all shipping materials have been removed from inside and/or underneath the fi rebox.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 12 J. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 14 3 3 Maintenance and Ser vice A. Maintenance T asks-Homeowner The following tasks may be performed annually by the homeowner . If you are uncomfortable performing any of the listed tasks, please call your dealer for a service ap- pointment.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 15 B. Maintenance T asks-Quali fi ed Service T echnician The following tasks must be performed by a quali fi ed ser- vice technician.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 16 Figure 3.1 IPI Pilot Flame Patterns • Inspect ori fi ce for soot, dirt and corrosion. V erify ori fi ce size is correct. See Service Parts List for proper ori fi ce sizing. • V erify manifold and inlet pressures.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 19 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 20 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 21 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of non- combustible materials (i.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 22 E. Hearth Extension W ARNING! Risk of Fire! Hearth extension required to protect combustible fl oors in front of appliance. W ARNING! Risk of Fire! DO NOT block ventilation slots. A minimum 1/4 in.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 23 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ...............................
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 24 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches...........
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 25 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 26 E. V ent Diagrams W ARNING! Risk of Fire. This appliance requires a mini- mum of 24 inches of vertical venting before attaching any elbow to the appliance. DO NOT attach elbow directly to the appliance.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 27 H 2 H 1 V 1 INST ALLED HORIZONT ALL Y 1. T op V ent - Horizontal T ermination V 1 H 1 Figure 7.3 Figure 7.4 1. T op V ent - Horizontal T ermination One Elbow T wo Elbows Fire Risk. Explosion Risk.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 28 1. T op V ent - Horizontal T ermination - (continued) Figure 7.5 Three Elbows H 1 V 2 H 2 V 1 V 1 H 1 V 2 H 2 2 ft 610 mm 7 in 178 mm * H 2 Max = 2 X V 2 3 ft 914 mm 2 ft 610 mm * H 2 Max = 2 X V 2 4 ft 1.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 29 2. T op V ent - V ertical T ermination No Elbow Figure 7.6 V 1 V 1 = 50 ft. Max. (15.2 m) V 1 = 3 ft. Min. (914 mm) Figure 7.7 V 1 H 1 V 2 2 ft 610 mm 1 ft 305 mm * 3 ft 914 mm 3 ft 914 mm * 4 ft 1.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 30 INST ALLED HORIZONT ALL Y V 2 H 2 H 1 V 1 Three Elbows V 1 H 1 H 2 V 2 H t Max. 2 ft 610 mm * * ** 7 in 178 mm 3 ft 914 mm * * ** 2 ft 610 mm 4 ft 1.2 m * * ** 4 ft 1.2 m 5 ft 1.5 m * * ** 8 ft 2.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 31 A* B A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 32 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 33 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 34 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: This appliance is top vented ONL Y . 1.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 35 B. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 36 1 0 10 I nstalling V ent Pipe A. Assemble V ent Sections Attach V ent to the Firebox Assembly Note: T he end of the pipe sectio ns wi th the lanc ed tabs will face toward the appliance.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 37 B. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl ue of the slip section over the outer fl ue of the pipe section.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 38 D. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separate the pieces of pipe.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 39 E. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 40 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP G. Install V ertical T ermination Cap • Attach the vertical.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 41 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 42 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 43 Figure 12.2 IPI Wiring Diagram ACCENT LIGHT #1 ACCENT LIGHT #2 EMBER BULBS (1-4) TO JUNCTION BOX (1 10V) MODULE I S FLAME SENSE IGNITER RC300 4.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 44 A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 45 B. Facing Material • Metal front faces may be covered with non-combustible materials only . • Facing and/or fi nishing materials must not interfere with air fl ow through louvers, operation of louvers or doors, or access for service.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 46 D. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify ef fects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a given dimension.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 47 1 4 14 Appliance Setup Figure 14.1 Glass T op T ab Detail. A. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Glass installation and removal should be performed only by a quali fi ed service technician.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 48 B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 49 F . Install Light Bulbs Note: Light bulbs are sh ipped in the instal lation manual bag. Ember Lights 1. Remove ember basket by lifting it from fi replace. There is one metal tab on each end of the ember box that engages slots in the ember basket.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 50 G. Install Refractory CAUTION: Refractory pieces are fragile! Carefully remove the refractory pieces from the packaging. 1. Locate the four refractory clips pre-installed in the top of the fi rebox and remove.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 51 I. Mystic Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 52 J. Install the Log Assembly GRA TE: Locate the pilot assembly . The pilot assembly is denoted in this instruction by a black or white arrow ( ) on each photo. For the purpose of placing logs according to this instruction, begin with the pilot on the left side.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 53 LOG NUMBER 2 (SRV2146-702): Place Log #2 as shown. The groove on the bottom of Log #2 engages with the grate bar . Pull log forward so it engages the far right grate tine as shown in Figure 6.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 54 Figure 15 Figure 14 Figure 16. LOG NUMBER 6 (SRV2146-706): Place Log #6 onto grate and log #1. The groove on the bottom of the log will engage the center grate bar and the other end of the log will rest on Log #1, with the tip touching Log #7.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 55 K. Ember/Mineral Wool Placement W ARNING! Risk of Explosion! DO NOT place embers directly over burner ports. Improperly placed embers inter- fere with proper burner operation. See instructions.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 56 Air Shutter Settings NG LP ESC-42ST 1-1/2 in. Fully Open O. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed service technician at the time of installation. The shutter adjustment rod is located adjacent to the gas valve.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 57 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 58 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 59 1 6 16 Reference Materials Appliance Dimensions T able A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 60 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 61 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 62 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 63 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) B. V ent Components Diagrams ( continued ) Figure 16.5 V ent Components Optional Wire Harness DESCRIPTION P ART NUMBER 10 ft.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 64 C. Service Parts ESC-42ST Beginning Manufacturing Date: Dec. 2008 Ending Manufacturing Date: ______ Service Parts Diagram Part number list on following page.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 65 C. Service Parts List ESC-42ST IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 66 Service Parts Beginning Manufacturing Date: Dec. 2008 Ending Manufacturing Date: Apr . 2010 V alve Assembly Diagram/ Parts List ESC-42ST IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 67 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • ESC-42ST • 2146-900 Rev . o • 5/12 68 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle ESC-42ST c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle ESC-42ST - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle ESC-42ST, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle ESC-42ST va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle ESC-42ST, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle ESC-42ST.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle ESC-42ST. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle ESC-42ST ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.