Heat-N-Glo Fireplace Model: A T -GRAND Patents Pending Installers Guide W ARNING: IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE INJUR Y OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSIST ANCE OR ADDITIONAL INFORMA TION CONSUL T A QUALIFIED INST ALLER, SER VICE AGENCY , OR THE GAS SUPPLIER.
i SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty . Prior to the first firing of the fireplace, READ the Using Y our Fireplace section of the Owners Guide .
ii Safety and W arning Information .................... i Section 1: Approvals and Codes ................ 1 Approval Listings and Codes .................................. 1 Appliance Certification ............................................ 1 Installation Codes .
1 Approval Listings and Codes Appliance Certification The Heat-N-Glo models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICA TION MODEL LABORA T O R Y TYPE S T ANDARD A T -GRAND Underwriters Direct V en t ANSI Z21.
2 2 Getting St arted Introducing the Heat-N-Glo Gas Appliances Heat-N-Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
3 VENTING AND INST ALLA TION 1 . Heat -N-Glo gas inserts are designed for recessed installations into solid fuel Masonry or Factory Built Non Combustible fireplaces that have been installed in accordance with the National, Provincial, S tate and local building codes.
4 When planning a fireplace insert installation, its necessary to determine: The vent system configuration to be used. Gas supply piping. Whether optional accessoriesdevices such as a wall switch, or remote controlare desired. Figure 1.
5 V ent System Inst allation Precautions Before starting installation of vent kits, the installer should read these instructions and the V ent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation.
6 A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the combustion air , one (1) pipe-to-cap adaptor , and one (1) SLK-991DA or SLK-980D V ertical termination Cap. NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible- vent pipe.
7 W ARNING MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF TOP . THESE MINIMUM HEIGHTS A RE NECESSAR Y IN THE INTEREST OF SAFETY . FIGURE 2 SHOWS MINIMUM HEIGHTS, PROVIDED THE TERMINA TION CAP IS A T LEAST 8- FEET FROM A VERTICAL W ALL.
8 Figure 3. W ARNING THE EXHAUST PIPE MUST ONL Y BE CONNECTED TO THE EXHAUST S T ARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINA TION CAP . THE INLET AIR PIPE MUST ONL Y BE CONNECTED TO THE INLET A I R COLLAR OF THE UNIT AND EITHER A T T ACHED TO THE INLET A I R COLLAR OF THE TERMINA TION CAP OR TERMINA TED IN THE CHIMNEY .
9 Figure 4 Figure 5 EXHAUST ST ARTING COLLAR INLET AIR ST ARTING COLLAR.
10 1. Place the insert into position. 2. Level the insert from side to side and from front to back. If necessary use the legs included in the manual bag. Screw the legs into the nuts installed in the bottom rear of the insert. T urn legs in until insert is level.
11 Step 4 The Gas Supply Line NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes . NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air .
12 Step 5 Gas Pressure Requirement s Pressure requirements for Heat-N-Glo gas appliances are shown in the table below . Pressure Nat u ra l Ga s Propane Minimum 5.0 inches 1 1.0 inches Inlet Pressure w . c. w . c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w .
13 Optional Accessories Optional fan and remote control kits require that 1 10- 120 V AC be supplied to the factory installed junction box. Run the cord out the notch in the surround and plug into a convenient outlet. Remote W all Switch Position the remote wall switch in the desired position on a wall.
14 NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE.
15 Remove the glass door from the unit. Cover the top of the burner with a single layer of ember material. Then sprinkle GE-93 on top of the burner . Save the remaining ember materials for use during fireplace servicing. Replace the glass door .
16 Combustible materials MUST NEVER overlap onto the front face. Step 8 Inst alling T rim Surrounds NOTE: REMOVE FRONT TRIM DOOR AND GLASS DOOR ASSEMBLIES FROM THE INSERT BEFORE SURROUND INST ALLA TION. 1 . Find the coiled low voltage wires and ON/OFF switch attached to outer right side of the insert.
17 3. Run the low voltage lead wires up the back of the right side of the surround and secure them with the three wire ties found there. Re-connect the low voltage wires to the short wires of the ON/OFF switch. 4. Remove and retain the four surround attachment screws at the corners of the face of the unit.
18 Step 9 Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Review safety warnings and cautions Read the Safety and Warning Information section at the beginning of this Installers Guide . Double-check for gas leaks Before lighting the appliance, double-check the unit for possible gas leaks.
19 4 Maint aining and Servicing Y our Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season.
20 S T ANDING PILOT 3/8" (10 mm) Figure 14. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADYNOT LIFTING OR FLOA TING . Figure 15. Pilot/Ignitor Flame Patterns.
21 PAR T P A RT DESCRIPTI O N PAR T N U M B E R Va lve L P SR V60–523 V al v e N G SRV60–52 2 Pi ez o I gn i tor SRV418-51 3 T h ermopi le SR V60 –51 2 T h ermocou ple SRV446-51 1 Pi lot O ri fi.
22 PAR T P A RT DESCRI PTI O N P A RT NUM BER B u r n er SR V475-328 A B u rn er O ri f i ce N G SR V57-800 B u rn er O ri f i ce LP SR V60-801 R ot ory S w i tc h SR V436-525A G lass Door A ssem bl y.
23 St anding Pilot (Cont.) Accessories AC C ESSO R Y P A RT D ESC RI P TI O N PAR T N U M B E R R em o te Co n t r ol Ki t R CH - 0 9A RC - S M A R T SM AR T - ST A T RC - M LT W all S wi t c h K i t .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle AT-GRAND c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle AT-GRAND - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle AT-GRAND, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle AT-GRAND va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle AT-GRAND, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle AT-GRAND.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle AT-GRAND. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle AT-GRAND ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.