1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building.
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance.
3 TABLE OF CONTENTS Safety and Warning Information . ................................................ 2 Service Parts List . ....................................................................... 4 Section 1: Approvals and Codes . ...................
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 10 11 12 13 14 16 15 17 4 6 2 1 3 8 7 9 Log Set Assembly 18 5 (NG , LP) Exploded Parts Diagram .
5 (NG , LP) S ervice Parts List / (GN, PL) Liste des pièces de rechange ITEM / PIÈCE ENGLISH / FRENCH DESCRIPTION SERIAL # / N° DE SÉRIE PART NUMBER / N° DE PIÈCE COMMON PARTS / PIÉCES COMMUNES.
6 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts Beginning M anufacturing Date: 9-97 Ending M anufacturing Date: ______ ITEM / PIÈCE DESCRIPTION SERIAL # / N° DE S.
7 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts Beginning M anufacturing Date: 9-01_ Ending M anufacturing Date: ______ ITEM / PIÈCE DESCRIPTION SERIAL # / N° DE .
8 Appliance Certification The Heat-N-Glo fireplace model discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories. Certification MODELS: 8000TVD LABORATORY: Underwriters Laboratories TYPE: Vented Gas Fireplace STANDARD: ANSI Z21.
9 2 Getting Started Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo B-type vent gas fireplaces are designed to op- erate with all exhaust gases expelled to the outside of the building. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control systems.
10 Figure 1. Diagram of 8000TVD 36 3/4” (932mm) 26 7/8” (681mm) 2 1/4” (56mm) 40 3/8” (1026mm) 9 1/8” (233mm) GAS LINE ACCESS 43” (1091mm) 48 3/8” (1229mm) 3 1/2” (89mm) 8 3/8” (212m.
11 3 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room. ABCD E 49” 22” 39 1/2” 56” 79” Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front .
12 Step 3. Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft. In the case of a gas appliance, spillage of the combustion gases may occur.
13 ! ! Step 4. Installing the Vent System A. Vent System Approvals Model 8000TVD is approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction.
14 ! C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent system above the roof line can be exterior to the building. D. Vent Termination WARNING: MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF T OP .
15 Figure 9. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration.
16 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. For Standing Pilot Ignition Wiring Appliance Requirements • This appliance DOES NOT require 110-120 VAC to operate.
17 For Intermittent Pilot Ignition (IPI) Wiring 3 Volt Transformer This appliance comes with a 3 volt transformer found in the manual bag. Plug the transformer leads to the green con- trol module (see Figure 12). Then plug the transformer into the side outlet on the junction box.
18 Step 10. Finishing Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances.
19 Glass Specifications: TEMPERED Figure 16. Placement of the Ember Material Figure 15. Glass Assembly Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
20 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle 8000TVD c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle 8000TVD - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle 8000TVD, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle 8000TVD va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle 8000TVD, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle 8000TVD.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle 8000TVD. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle 8000TVD ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.