Manuel d'utilisation / d'entretien du produit 6000TR-OAK-IPI du fabricant Heat & Glo LifeStyle
Aller à la page of 35
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 1 Underwriters Laboratories Listed Models: 6000TR-OAK 6000TR-OAK-IPI Owner ’ s Manual Installation and Operation Î - Do not store or use gasoline or other flammable vapors and liquids in the vi- cinity of this or any other appliance.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 3 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists .....................................................
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 4 Part number list on following page. 5 4 6 Log Set Assembly 2 1 3 11 10 12 8 7 9 13 (NG , LP) Exploded Parts Diagram Service.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 5 IT E M CO M MO N P A RTS SER IA L # P ART NUM BER 1S u r r o u n d PRE 00232 4002 POST 00232400 2 385- 130 2026-108 2 H ood.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 6 (NG , LP) Exploded Part s Diagram Service Parts 6000TR-OAK-IPI IT E M DESCRI PTIO N SERI A L # P A RT NUM BER 1 V alv e B r.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 7 (NG , LP) Exploded Part s Diagram Service Parts 6000TR-OAK ITE M DESCRIP TI O N SERI A L # P A RT NUM BER 1 O N/OF F Ro c k.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 9 Î For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in wh.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 10 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 11 Figure 1. Diagram of the 6000TR-OAK, 6000TR-OAK-IPI TOP VENT COLL ARS REAR VE NT COL LA RS GAS LINE ACCE SS ELE CTR ICAL A.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 12 3 Inst alling the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fireplace within a room.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 13 Framing should be constructed of 2 X 4 lumber or heavier . A . ............. 42”* B . ......... 38 1/2” C . ............... 22” D . ......... 42 3/4” E . ......... 27 7/8” Figure 3.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 14 Figure 4. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . D V P 9 0 S T 12-9/16 11- 1/ 4 7-1/4 1-1/4 TYP 1/2 TYP 8-9/16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 15 Figure 5. V ent System Component s and T ermination Kits Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP-series direct vent pipe components and terminations (see Figures 4 and 5).
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 16 Figure 6. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) CAP V Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7).
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 17 HORIZONT AL VENTING Kit No. H Max. Run DV P-T RA P 24" (610 mm) Figure 1 1. Corner Installation NOTE: This model is tested and approved to use 45° elbows in corner installations.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 18 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 19 Figure 14. V enting with T wo 90° Elbows VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 20 Figure 16. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 21 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H + H 1 (FT .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 22 ! B. Inst alling V ent Component s After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly .
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 23 3. Continue Adding V ent Component s W ARNING: INST ALLA TION OF THIS FIREPLACE REQUIRES THE USE OF HEA T SHIELD 570-290 ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM. Figure 20 T o Inst all the Heat Shield: 1.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 24 5. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 25 Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole. NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm).
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 26 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Minimum Clearances for T erminations A = 12" ....................... clearances above grade, veran- da, porch, deck or balcony B = 12" .
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 27 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 28 Step 5. Installing the Optional Heat-Zone-Gas Kit NOTE: There must be NO INSULA TION or other com- bustibles inside the framed firestop opening. Figure 32. 1. Remove the knockout from the fireplace and discard it (see Figure 32).
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 29 Figure 34. Gas Supply Line • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 30 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 31 Intermittent Pilot Ignition (IPI) Wiring 3 V olt T ransformer This appliance comes with a 3 volt transformer . The trans- former plugs into the junction box and the two leads plug into the green control module (see Figure 37).
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 32 Step 10. Finishing Figure 38 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 33 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 34 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev . K • 5/06 35 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle 6000TR-OAK-IPI c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle 6000TR-OAK-IPI - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle 6000TR-OAK-IPI, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle 6000TR-OAK-IPI va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle 6000TR-OAK-IPI, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle 6000TR-OAK-IPI.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle 6000TR-OAK-IPI. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle 6000TR-OAK-IPI ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.