Manuel d'utilisation / d'entretien du produit 6000GL-IPI-R du fabricant Heat & Glo LifeStyle
Aller à la page of 67
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 1 Models: 6000GL-IPI-S 6000GL-IPI-R 6000GL-IPILP-S 6000GL-IPILP-R • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: _____.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 4 Î = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 50 B. Facing Material . . . . . . . . . . . . . .
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 5 B. Limited Lifetime W arranty Î.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 6 B. Limited Lifetime W arranty (continued) Î.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 7 C. BTU Speci fi cations This product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable s.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer .
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 12 J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 15 Figure 3.1 IPI Pilot Flame Patterns.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 19 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 21 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .............
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 22 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16.B for vent component information.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 24 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 T op V ent - Horizontal T ermination T op V ent - Hor.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 25 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 26 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the fl ue restrictor should be used.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 27 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 28 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 29 Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45º Elbow H 1 H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 30 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 31 Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 H 1 V 1 INST ALL ED HORIZONT ALL Y H 1 H 2 V 2 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 32 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 33 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 34 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 35 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 36 A. T op V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 37 B. Rear V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 38 D. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 39 1 0 10 Inst alli ng V ent Pi pe (D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 40 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 41 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 42 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 43 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 44 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 45 Figure 10.20 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 46 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 47 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 48 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 49 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 50 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 51 C. Doors Only doors certi fi ed for use with this appliance model may be used.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 52 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 53 F . Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually .
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 54 G. Install the Log Assembly Log Assembly: LOGS-6000GL STEP 2. Place the metal grate on top of the burner . Position the legs of the grate into the forward set of indentations in the burner top.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 55 Figure 14.1 1 T op View STEP 5. Log #3 (SR V2102-105): Place log #3 on top of the burner surface in front of the hump. The bottom of the log is contoured to match some of the burner surface features.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 56 K. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 57 A. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 58 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 59 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 60 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 61 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 62 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 63 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 64 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 65 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 8-3/4 in.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 66 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TV.
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 70 D. Contact Information - NOTES - ________________________________________________________________________________ _______.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle 6000GL-IPI-R c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle 6000GL-IPI-R - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle 6000GL-IPI-R, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle 6000GL-IPI-R va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle 6000GL-IPI-R, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle 6000GL-IPI-R.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle 6000GL-IPI-R. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle 6000GL-IPI-R ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.