Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 1 Model: Escape-36DV • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 4 Not e: This installation must c onform wi th local c odes. In the absenc e of local c odes you must c omply wit h the Nation al Fuel Gas Code, A NSI Z2 23. 1- latest edition in th e U .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 5 F . Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in ever.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 6 A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 7 3 3 F raming and Clearances Note: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 8 Fire Risk. • Construct chase to all clearance speci fi cations in manual. • Locate and install appliance to all clearance speci fi cations in manual.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 9 D. Mantel Projections NON-COMBUSTIBLE MA TERIAL 7-1/2 IN. MINIMUM UNLIMITED E. Hearth Extension The base of the fi replace may sit on a combustible surface.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 10 4 4 T er mination Locations A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 1 1 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 12 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 13 H 1 V 1 Figure 5.3 Figure 5.4 D. V ent Diagrams 1. T op V ent - Horizontal T ermination One Elbow T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 1 Minimum H 1 Maximum 1 ft. 305 mm 1-1/2 ft.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 14 Figure 5.5 1. T op V ent - Horizontal T ermination - (continued) Three Elbows V 1 + V 2 Minimum H Maximum 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 2 ft. 610 mm 2 ft. 610 mm 2-1/2 ft. 762 mm 5 ft.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 15 2. T op V ent - V ertical T ermination No Elbow Figure 5.6 V 1 V 1 = 40 ft. Max. (12.2 m) FLUE RESTRICTOR Flue Restrictor Instructions 1. The fl ue restrictor (Figure 5.7) is located behind the right side panel.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 16 Figure 5.9 T wo Elbows H 1 V 1 V 2 V 1 + V 2 Minimum H Maximum 1-1/2 ft. 457 mm 2 ft. 610 mm 2 ft. 610 mm 2-1/2 ft. 762 mm 2-1/2 ft. 762 mm 5-1/2 ft. 1676 mm 3-1/2 ft. 1067 mm 8-1/2 ft.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 17 Figure 5.10 2. T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum 1-1/2 ft. 305 mm 2 ft. 610 mm 2 ft.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 18 A. Pipe Clearances to Combustibles 6 6 V ent Clearances and F raming B. W all Penetration Framing Combustible W all Penetration Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 19 C. V ertical Penetration Framing Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/ fl oor (see Figure 6.4).
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 20 7 7 Appliance Preparation NAILING T ABS (BOTH SIDES) CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. The diagram shows how to properly position, level, and secure the appliance (see Figure 7.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 21 C. Installing Non-combustible Facing Material Figure 7.3 Complete Installation of Non-combustible Facing Material Fire Risk. • Follow these instructions exactly . • Facing materials must be installed properly to prevent fi re.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 22 A. Assembly of V ent Sections (DVP Pipe) Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 1-1/2 inches. • Use pilot holes for screws.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 23 Figure 8.4 Seams Note: Make sure that the seams are not aligned to prevent unintentional disconnection.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 24 B. Disassembly of V ent Sections T o disassemble any two pieces of pipe, rotate either section (see Figure 8.10), so that the seams on both pipe sections are aligned (see Figure 8.1 1).
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 25 C. Installing Heat Shield and Horizontal T ermination Cap Fire Hazard Impaired performance of appliance • T elescoping flue section of termination cap MUST be used when connecting pipe section to termination cap.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 26 SCREWS CAULK STORM COLLAR (1 of 3) D. Installing Roof Flashing and V ertical T ermination Cap T o install roof fl ashing see Figure 8.13. For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 8.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 27 Figure 8.16 Assembling the Storm Collar Figure 8.17 Assembling the Storm Collar Around the Pipe Connect both halves of the storm collar with two screws (see Figure 8.16). Wrap the storm collar around the exposed pipe section and align brackets.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 28 Note: H av e the gas supply line inst alled in acc ordance w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 . Installation shou ld b e done by a quali fi ed ins taller approv ed and/or li censed as requ ired b y the locality .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 29 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 30 A. Recommendation for Wire This appliance requires 1 10-120 V AC be wired to the junction box for proper operation of the appliance (Intelli fi re ignition).
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 31 IPI VA LV E ORANGE GREEN RED RED GROUND PIGT AIL GREEN AUX CONNECTION FRONT VIEW REAR VIEW G Y R BLACK BLACK AC PLUG FA N CONNECTI.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 32 WHT WHT BLK BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebo x Romex Connector D.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 33 1 1 11 Finishing A. Mantel Projections Figure 1 1.1 shows the minimum vertical and correspond- ing maximum horizontal dimensions of appliance mantels or other combustible projections above the opening edge of the appliance.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 34 Figure 1 1.4. Non-combustible Finishing Material Requirements FRAMING ST ANDOFF COMBUSTIBLE OK 7-1/2 in. MIN. NON-COMBUSTIBLE MA TERIAL 12 IN. 43 IN. 54 IN. FINISH WALL NON-COMBUSTIBLE HIGH TEMPERATURE (300º F / 149º C MIN.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 35 1 2 12 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 36 Log Assembly: LOGS-ESCAPE F . Positioning the Logs 2012-925C 10/06 1 1 1 1 2 2 8 8 6 6 5 5 4 4 3 3 7 7 CAUTION: Logs are fragile! Carefully remove the logs from the packaging. Step 1.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 37 LOG #4 (SRV2012-162): Place log #4 on top of the burner in front of log 3. The triangle shaped groove in the bottom fi ts onto the right tine of the grate. The right side is pushed back until it touches the back log.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 38 LOG #6 (SRV2012-164): Place log #6 on the left side of the grate with the groove on the end of the log fi tting into the vertical left tine of the grate. The burned end of the log rests in the groove on the left side of log #3.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 39 LOG #8 (SRV2012-166): Place log #8 on top of log #5. The fl at bottom of log #8 sits on the large fl at area of log #5. The burned end of log #8 rests on the second vertical tine from the right of the grate.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 40 Figure 12.13 Glass Assembly G. Glass Assembly Handle glass doors with care. • Inspect the gasket to ensure it is undamaged. • Inspect the glass for cracks, chips or scratches. • Do NOT strike, slam or scratch glass.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 41 A. Before Lighting Appliance Before lighting this appliance determine if it has a Stand- ing Pilot or Intelli fi re ignition system by opening the con- trol access panel to view wiring system and gas valve.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 42 B. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 43 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 44 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 45 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 46 1 5 15 Maintaining and Ser v icing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 47 Figure 15.1 CAUTION Skin oils can cause early bulb failure. • Do not touch bulb with bare hands. • Use paper towel or rubber gloves when handling bulb. • If bulb has been touched, wipe it clean with rubbing alcohol.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 48 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 49 1 6 16 R eference Mater ials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions and clearances refer to Section 3.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 50 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 51 (Shown with optional extended heat shield) W all Shield Fir e sto p Heat Shield DVP-TRAP1 DVP- TRAPK1 Hori zo ntal T erminat ion C.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 52 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 53 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI appliances only.) 1 in. (25 mm) 14 in. (356 mm) 3/8 in.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 54 C. Service Parts Service Parts Diagram ESCAPE-36DV Beginning Manufacturing Date: Sept.
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 55 C. Service Parts List ESCAPE-36DV IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 56 1 2 3 4 5 6 7 8 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04-08 57 D. Limited Lifetime W arranty © 2007 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 BASIC ONE-YEAR W ARRANTY .
Heat & Glo • Escape-36DV • 2012-900 • Rev . AA • 04/08 58 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle 36DV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle 36DV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle 36DV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle 36DV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle 36DV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle 36DV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle 36DV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle 36DV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.