Manuel d'utilisation / d'entretien du produit ESCAPE-42DV du fabricant Heat & Glo
Aller à la page of 57
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 1 Model: Escape-42DV • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 2 Congratulations Congratulations on selecting a Heat & Glo gas appliance —an elegant and clean alternative to wood burning appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety , reliability , and ef fi ciency .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Speci fi cations . . . . . . . . . . . . .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 4 B. Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC).
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 5 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwel.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 6 A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 7 D. Inspect Firebox Surface cracking or crazing of fi rebrick material is normal and expected. The following types of cracks are acceptable and do not require replacement of the unit or the fi rebox: • Cracks that do not propagate entirely thru the material.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 8 3 3 F raming and Clearances Note: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 9 Fire Risk. • Construct chase to all clearance speci fi cations in manual. • Locate and install appliance to all clearance speci fi cations in manual.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 10 NON-COMBUSTIBLE MA TERIAL 4 INCH MINIMUM UNLIMITED D. Mantel Projections Figure 3.3 Clearances to mantels or other combustibles above appliance Figure 3.4 Clearances to Mantel Legs or W all Projections (Acceptable on both sides of opening.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 1 1 A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 12 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 13 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 14 Note: Must have a 24 inches minimum vertical vent before at taching any elbow to t he unit. V 1 H 1 Figure 5.3 Figure 5.4 D. V ent Diagrams 1. T op V ent - Horizontal T ermination One Elbow T wo Elbows H 2 H 1 V 1 INST ALLED HORIZONT ALL Y Fire Risk.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 15 Note: Must have a 24 inches minimum vertical vent before at taching any elbow to t he unit.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 16 2. T op V ent - V ertical T ermination No Elbow Figure 5.6 Figure 5.7 T wo Elbows V 1 V 1 = 50 ft. Max. (15.2 m) V 1 = 3 ft. Min. (914mm) FLUE RESTRICTOR FLUE RESTRICTOR NOTE: A fl ue restrictor can only be used in vent runs that include no elbows and exceed 30 ft.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 17 Figure 5.8 2. T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y V 2 H 2 H 1 V 1 V 1 H 1 H 2 V 2 H t Max. 2 ft 610 mm * * ** 7 in 178 mm 3 ft 914 mm * * ** 2 ft 610 mm 4 ft 1.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 18 A. Pipe Clearances to Combustibles 6 6 V ent Clearances and F raming B. W all Penetration Framing Combustible W all Penetration Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 19 C. V ertical Penetration Framing Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/ fl oor (see Figure 6.4). • Frame the area with the same sized lumber as used in ceiling/ fl oor joist.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 20 7 7 Appliance Preparation CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. The diagram shows how to properly position, level, and secure the appliance (see Figure 7.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 21 C. Installing Non-combustible Facing Material Figure 7.3 Complete Installation of Non-combustible Facing Material Fire Risk. • Follow these instructions exactly . • Facing materials must be installed properly to prevent fi re.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 22 Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 1-1/2 inches. • Use pilot holes for screws. • Screws must not exceed one inch long.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 23 Assembling DVP-12A Slip Sections The outer fl ue of the slip section should slide over the outer fl ue of the pipe section and into (inner fl ue) the last pipe section (see Figure 8.6) .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 24 B. Disassembly of V ent Sections T o disassemble any two pieces of pipe, rotate either section (see Figure 8.10), so that the seams on both pipe sections are aligned (see Figure 8.1 1). They can then be carefully pulled apart.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 25 C. Installing Heat Shield and Horizontal T ermination Cap Installing the Horizontal T ermination Cap V ent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 26 SCREWS CAULK STORM COLLAR (1 of 3) D. Installing Roof Flashing and V ertical T ermination Cap T o install roof fl ashing see Figure 8.13. For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 8.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 27 Figure 8.16 Assembling the Storm Collar Figure 8.17 Assembling the Storm Collar Around the Pipe Connect both halves of the storm collar with two screws (see Figure 8.16). Wrap the storm collar around the exposed pipe section and align brackets.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 28 Note: Hav e the gas supp ly line installed in acc ordanc e w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 . Installation shou ld b e done by a quali fi ed ins taller approv ed and/or li censed as requ ired b y the locality .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 29 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 30 A. Recommendation for Wire This appliance requires 1 10-120 V AC be wired to the factory installed junction box.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 31 Figure 10.1 Intelli fi re Pilot Ignition (IPI) W iring Diagram IPI VA LV E ORANGE GREEN RED RED GROUND PIGT AIL GREEN AUX CONNECTION F.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 32 Figure 10.2 IPI Wiring diagram for optional PVK-80 power vent termination cap PVK-80 MOTOR V ACUUM SWITCH NEUTRAL 120V AC HOT (ORANGE) .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 33 A. Mantel Projections Figure 1 1.1 shows the minimum vertical and correspond- ing maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 34 C. Finishing Materials Requirements Note: Optional fi rescreen sits out 1-1/2 inches from the face of the fi replace. When using thin fi nishing material, you may want to use thicker non-combustible backer board to bring the fi nishing material fl ush with the fi re screen.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 35 1 2 12 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 36 E. Positioning the Logs Log Assembly: LOGS-Escape-42 If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 37 LOG #1 (SRV750-706) (Three): There are quantity three (3) of log #1. Place one of the logs on the fl oor of the fi replace on the left side of the grate between the fi rebox and the left grate tine.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 38 LOG #4 (SRV2012-162): Place log #4 on top of the burner in front of log 3. The triangle shaped groove in the bottom fi ts onto the right grate tine. The right side is pushed back until it touches the back log.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 39 LOG #6 (SRV2052-702): Place log #6 on the left side of the grate with the groove on the end of the log fi tting into the vertical left grate tine. The other end has a slot in the bottom side.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 40 F . Glass Assembly Handle glass doors with care. • Inspect the gasket to ensure it is undamaged. • Inspect the glass for cracks, chips or scratches. • Do NOT strike, slam or scratch glass.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 41 A. Before Lighting Appliance This appliance has an Intelli fi re ignition system. Before operating this appliance have a quali fi ed tech- nician: • Remove all shipping materials from inside the fi rebox.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 42 B. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 43 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 44 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 45 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 46 1 5 15 Maintaining and Ser v icing Applianc e Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 47 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 48 1 6 16 R eference Mater ials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions and clearances refer to Section 3.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 49 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 50 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 51 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 52 C. Service Parts Service Parts Diagram ESCAPE-42DV Beginning Manufacturing Date: Mar . 2005 Ending Manufacturing Date: ______ 9 10 11 12 13 14 15 16 17 Part number list on following page.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 53 C. Service Parts List ESCAPE-42DV IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 54 Service Parts V alve Assembly Parts List ESCAPE-42DV Beginning Manufacturing Date: Mar . 2005 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 55 D. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its res.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 56 D. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.
Heat & Glo • Escape-42DV • 2052-900 Rev . R • 10/08 57 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo ESCAPE-42DV c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo ESCAPE-42DV - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo ESCAPE-42DV, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo ESCAPE-42DV va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo ESCAPE-42DV, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo ESCAPE-42DV.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo ESCAPE-42DV. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo ESCAPE-42DV ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.