Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards.
2 Model LFC Low-Profile Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection.
3 Model LFC Low-Profile Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Lifting / Hanging Instructions ................ 3 Dimensions / Weights ...................... 4 Filter Sizes / Quantity . . . . .
4 Model LFC Low-Profile Fan Coil ® Unit Dimensions Unit Size I J K Width Inlet Outlet w/o Filter w/ 2 in. Filter w/ 4 in. Filter Height Width Height Width 15 40 42 44 8.0 11.0 38 9.0 36 4.0 6.75 20 40 42 44 11.0 14.0 38 12.0 36 6.5 6.75 25 40 42 44 13.
5 Model LFC Low-Profile Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B 15 7.63 0.75 20 10.13 0.75 25 12.63 0.875 30 15.13 0.875 45 15.
6 Model LFC Low-Profile Fan Coil ® Unit Size A B 4 row 6 row 8 row CDCDCD 30 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 45 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 50 13.50 7.75 0.625 0.625 0.625 0.875 0.625 1.125 65 17.00 9.50 0.875 0.875 0.
7 Model LFC Low-Profile Fan Coil ® System Start-Up For proper unit function and safety , follow everything in this start-up procedur e in the order pr esented. This is to be done after the electrical connections are complete. PRE-ST ART CHECK LIST 1.
8 Model LFC Low-Profile Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Broken fa.
9 Model LFC Low-Profile Fan Coil ® Hot W ater , Chilled W ater Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections. USE WET TOWEL TO AVOID BURNING COIL CONNECTION GROMMETS.
10 Model LFC Low-Profile Fan Coil ® Steam Coils, General - continued 3. Standard steam coils are pitched in the casings when installed for horizontal airflow. The casing must be level after the unit is installed for proper condensate drainage. If condensate is not removed, the coil will suffer from water hammering and will have a shortened life.
11 Model LFC Low-Profile Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r elubricatable and will need to be regr eased depending on fan use.
12 Model LFC Low-Profile Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance.
13 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ ________________________________________________.
14 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ ________________________________________________.
15 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ ________________________________________________.
16 464496 • LFC, Rev . 1, August 2004 Copyright 2004 © Greenheck Fan Corporation Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the shipment date.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Greenheck Fan LFC c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Greenheck Fan LFC - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Greenheck Fan LFC, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Greenheck Fan LFC va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Greenheck Fan LFC, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Greenheck Fan LFC.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Greenheck Fan LFC. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Greenheck Fan LFC ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.