306–993 Rev . D Supersedes Rev . B and PCN C First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Hydra-Clean ) Pressure W ashers 42 bar , 4.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . .
W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .
4 306-993 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re - sult in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 306-993 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE OR EXPLOSION HAZARD on page 4. Although water generally provides a natural electrical ground, the following equipment must be grounded if the cleaning chemical are volatile.
Setup Connect Hoses and Mount Pump Connect hoses and pump as follows: NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket.
7 306-993 Setup D U B F M J R P KEY A Barbed Hose Stud B Suction Hose C Pump Intake housing D Bracket E Screw , Lockwasher , and Nut F Pump Runaway V alve G Air Line Lubricator H Pu.
8 306-993 Operation General Information The following instructions are for operation of the Monark 5:1 Ratio Hydra–Clean Pressure W ashers Model 205–985 and Model 207–860.
Operation W ARNING T o avoid serious injury , including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using See Fig. 2. Prepare cleaning solution as instructed, observing all safety precautions.
10 306-993 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to relieve the pressure .
11 306-993 Service General W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. See Parts illustration for referenced items. Shut of f the air supply to the pump and relieve the pressure .
12 306-993 Parts 0676 8 17 (MODEL 205–985) 11 4 13 2 18 15 21 19 14 16 20 3 5 12 6 Model 205–985 Monark Hydra-Clean and Model 207–860 Monark Hydra-Clean 1 7 8 8 9 10 (MODEL 207–860) 22 23.
13 306-993 Parts Model 207–860 Monark Hydra-Clean Ref No. Part No. Description Qty . 1 214–847 AIR LINE LUBRICA TOR 1 2* 206–300 FIL TER, fluid intake 1 3 224–343 5:1 Ratio Monark Pump See man.
14 306-993 Accessories Stainless Steel Spray Tips AIR SUPPL Y T O PUMP TIP NO. ORIFICE SIZE SPRA Y ANGLE 70 PSI (4.8 bar , 0.48 MPa) 100 psi (7 bar , 0.7 MPa) NO . SIZE ANGLE GPM CFM WP GPM CFM WP 164–435 .043 40 160–964 .043 25 164–434 .052 25 164–436 .
15 306-993 Dimensions 24.5” (622 mm) 1 1.75” (298 mm) T echnical Data Air pressure range 40 to 120 psi (2.8 to 8.4 bar , .28 to .84 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air volume requirements 8.
16 306-993 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco Hydra-Clean 205-985 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco Hydra-Clean 205-985 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco Hydra-Clean 205-985, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco Hydra-Clean 205-985 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco Hydra-Clean 205-985, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco Hydra-Clean 205-985.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco Hydra-Clean 205-985. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco Hydra-Clean 205-985 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.