GSC13 S plit S ystem A ir C onditioner

13 SEER / R-22 1½ to 5 T ons

Contents

Nomenclature 2 Product Specifications 3 Expanded Cooling Data 4 AHRI Ratings 18 Dimensions 18 Wiring Diagram 19 Accessories 20

Goodman Mfg Split System Air Conditioner — Contents diagram (page 1)
Fig. 1 · Contents
  • Standard Features
  • Energy-efficient compressor
  • Quiet condenser fan system
  • Factory-installed liquid-line filter drier
  • Copper tube/aluminum fin coil
  • For use with R-22 refrigerant; charged with inert gas for shipping
  • R-22 piston kit included
  • Brass liquid and suction service valves with sweat connections
  • Contactor with lug connections
  • Ground lug connection
  • ETL Listed
  • Cabinet Features
  • Louver design sound control top
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

* Complete warranty details available from your local dealer or at www.goodmanmfg.com

SS-GSC13 www.goodmanmfg.com 11/13 Supersedes 9/13

Page 2 of the Goodman Mfg Split System Air Conditioner user manual — G C
Page 2 · cliquer pour agrandir
Page 2

N omenclature

G C

A S

A

Brand Engineering * G Goodman® (Standard Minor Revision Feature Set Models)

Engineering * Product Category Major Revision S Split System Electrical Unit Type 1 208/230 V, 1 Phase, 60 Hz C Condenser R-22 H Heat Pump R-22 Nominal Capacity 018 1½ Tons 042 3½ Tons Efficiency 024 2 Tons 048 4 Tons 13 13 SEER 030 2½ Tons 060 5 Tons 036 3 Tons

* Neither used for order entry or inventory management.

4,5 9 · 6,7,8

Page 3 of the Goodman Mfg Split System Air Conditioner user manual — S pecifications
Page 3 · cliquer pour agrandir
Page 3

S pecifications

GSC13 0181G*GSC13 0241F*GSC13 0301E*GSC13 0361G*GSC13 0421C*GSC13 0481C*GSC13 0601D* Cooling Capacities Tonnage Decibels1½ 762 762½ 723 753½ 764 765 77 Compressor RLA LRA6.8 4010.8 5613.5 6813.4 7415.4 8719.2 11221.8 137 Condenser Fan Motor Horsepower FLA1/8 0.651/8 0.651/8 0.71/6 1.1¼ 1.5¼ 1.5¼ 1.5 Refrigeration System Refrigerant Line Size Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) ³ Valve Type Refrigerant Charge⅜" ¾" ⅜" ¾" Sweat 87⅜" ¾" ⅜" ¾" Sweat 77⅜" ¾" ⅜" ¾" Sweat 66⅜" ⅞" ⅜" ¾" ³ Sweat 77⅜" 1⅛" ⅜" ¾" ³ Sweat 108⅜" 1⅛" ⅜" ⅞" 4 Sweat 128⅜" 1⅛" ⅜" ⅞" 4 Sweat 118 Electrical Data AC Volts-Hz Min. Circuit Ampacity¹ Max. Overcurrent Device² Min / Max Volts Electrical Conduit Size208-230/ 60 9.2 15 197/253 ½" or ¾"208/230-60 14.2 25 197/253 ½" or ¾"208/230-60 17.6 30 197/253 ½" or ¾"208/230-60 17.9 30 197/253 ½" or ¾"208/230-60 20.8 35 197/253 ½" or ¾"208/230-60 25.5 40 197/253 ½" or ¾"208/230-60 28.8 50 197/253 ½" or ¾" Equipment Weight (lbs) Ship Weight (lbs)116 130116 130142 159141 159141 159176 194207 225
Goodman Mfg Split System Air Conditioner — S pecifications diagram (page 3)
Fig. 2 · S pecifications

¹ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. ³ Installer will need to supply ¾” to ⅞” adapters for suction line connections. ⁴ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.

  • Always check the S&R plate for electrical data on the unit being installed.
  • Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge. System charge must be adjusted per Installation Instructions Final Charge Procedure.
Page 4 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130181G*
Page 4 · cliquer pour agrandir
Page 4

E xpanded R atings — GSC130181G*

MBh 17.9 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1 17.6 19.1 20.5 16.7 17.2 18.6 20.0 15.9 16.3 17.7 19.0 14.7 15.1 16.4 17.6 S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43 ∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10 kW 1.06 1.08 1.12 1.16 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.35 1.30 1.33 1.38 1.43 1.36 1.39 1.45 1.50 1.41 1.45 1.50 1.56 Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7 HI PR 137 147 155 162 154 165 174 182 175 188 198 207 199 214 226 236 224 241 254 265 247 266 281 293 LO PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 5 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130181G* ( cont .)
Page 5 · cliquer pour agrandir
Page 5

E xpanded R atings — GSC130181G* ( cont .)

MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7 18.1 18.9 20.2 17.3 17.6 18.4 19.7 16.4 16.7 17.5 18.7 15.2 15.5 16.2 17.3 S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80 ∆T 25 25 23 20 25 25 23 20 24 25 23 20 24 24 24 20 22 23 23 20 21 21 22 19 kW 1.08 1.10 1.14 1.18 1.17 1.20 1.24 1.29 1.25 1.28 1.33 1.38 1.32 1.36 1.41 1.46 1.39 1.42 1.47 1.53 1.44 1.48 1.53 1.59 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.8 HI PR 140 150 159 165 157 169 178 186 178 192 202 211 203 218 231 240 228 246 259 271 252 271 287 299 LO PR 63 67 73 78 67 71 78 83 69 74 81 86 73 78 85 90 76 81 89 94 79 84 92 98 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 6 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130241F*
Page 6 · cliquer pour agrandir
Page 6

E xpanded R atings — GSC130241F*

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 7 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130241F* ( cont .)
Page 7 · cliquer pour agrandir
Page 7

E xpanded R atings — GSC130241F* ( cont .)

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 8 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130301**
Page 8 · cliquer pour agrandir
Page 8

E xpanded R atings — GSC130301**

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 9 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130301** ( cont .)
Page 9 · cliquer pour agrandir
Page 9

E xpanded R atings — GSC130301** ( cont .)

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 10 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded C ooling D ata — GSC130361G*
Page 10 · cliquer pour agrandir
Page 10

E xpanded C ooling D ata — GSC130361G*

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 11 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded C ooling D ata — GSC130361G* ( cont .)
Page 11 · cliquer pour agrandir
Page 11

E xpanded C ooling D ata — GSC130361G* ( cont .)

IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power

Page 12 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130421C*
Page 12 · cliquer pour agrandir
Page 12

E xpanded R atings — GSC130421C*

MBh 40.4 41.6 45.0 48.3 39.4 40.6 44.0 47.2 38.5 39.6 42.9 46.1 37.6 38.7 41.9 44.9 35.7 36.7 39.8 42.7 33.1 34.0 36.8 39.5 S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43 ∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 15 11 20 19 15 11 19 17 14 10 kW 2.22 2.28 2.36 2.45 2.42 2.48 2.58 2.67 2.60 2.67 2.77 2.87 2.76 2.83 2.93 3.05 2.89 2.97 3.08 3.19 3.01 3.08 3.20 3.32 Amps 8.4 8.6 8.8 9.1 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.6 10.3 10.6 10.9 11.3 11.0 11.2 11.6 12.0 11.6 11.8 12.2 12.6 HI PR 133 143 151 157 149 160 169 176 169 182 192 201 193 207 219 228 217 233 246 257 240 258 272 284 LO PR 63 67 73 78 66 71 77 82 69 74 80 85 73 77 84 90 76 81 88 94 79 84 91 97 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 13 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130421C* ( cont .)
Page 13 · cliquer pour agrandir
Page 13

E xpanded R atings — GSC130421C* ( cont .)

MBh 41.8 42.6 44.6 47.6 40.8 41.6 43.6 46.5 39.9 40.6 42.6 45.4 38.9 39.7 41.5 44.3 37.0 37.7 39.5 42.1 34.2 34.9 36.5 39.0 S/T 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.80 ∆T 24 24 22 19 24 24 23 19 23 24 23 20 23 23 23 20 22 22 22 19 20 20 21 18 kW 2.26 2.32 2.41 2.50 2.47 2.53 2.63 2.73 2.65 2.72 2.82 2.93 2.81 2.88 2.99 3.11 2.95 3.02 3.14 3.26 3.07 3.14 3.26 3.39 Amps 8.5 8.7 9.0 9.3 9.2 9.4 9.6 10.0 9.9 10.1 10.4 10.8 10.5 10.8 11.1 11.5 11.1 11.4 11.8 12.2 11.8 12.0 12.4 12.9 HI PR 135 146 154 160 152 163 173 180 173 186 196 205 197 212 224 233 221 238 251 262 244 263 278 290 LO PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 14 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130481C*
Page 14 · cliquer pour agrandir
Page 14

E xpanded R atings — GSC130481C*

MBh 46.3 47.7 51.6 55.4 45.2 46.6 50.4 54.1 44.2 45.5 49.2 52.8 43.1 44.4 48.0 51.5 40.9 42.1 45.6 48.9 37.9 39.0 42.2 45.3 S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42 ∆T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 10 19 17 14 10 kW 2.58 2.65 2.75 2.85 2.82 2.89 3.00 3.11 3.03 3.10 3.22 3.34 3.21 3.29 3.42 3.55 3.37 3.45 3.58 3.72 3.50 3.59 3.73 3.87 Amps 10.3 10.5 10.9 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.3 14.9 14.3 14.7 15.2 15.7 HI PR 133 143 151 158 149 161 170 177 170 183 193 201 194 208 220 229 218 234 247 258 241 259 273 285 LO PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 90 76 81 88 94 78 83 91 97 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 15 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130481C* ( cont .)
Page 15 · cliquer pour agrandir
Page 15

E xpanded R atings — GSC130481C* ( cont .)

MBh 48.0 48.9 51.2 54.6 46.8 47.7 50.0 53.3 45.7 46.6 48.8 52.1 44.6 45.5 47.6 50.8 42.4 43.2 45.2 48.3 39.3 40.0 41.9 44.7 S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 ∆T 24 23 22 19 24 24 22 19 23 24 22 19 23 23 23 20 22 22 22 19 20 20 21 18 kW 2.63 2.70 2.80 2.90 2.87 2.95 3.06 3.17 3.09 3.16 3.28 3.41 3.27 3.36 3.48 3.62 3.43 3.52 3.65 3.80 3.57 3.66 3.80 3.95 Amps 10.5 10.7 11.0 11.4 11.3 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.3 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 HI PR 136 146 154 161 152 164 173 181 173 187 197 206 197 213 224 234 222 239 252 263 245 264 279 291 LO PR 64 68 74 79 68 72 79 84 70 75 82 87 74 79 86 91 77 82 90 96 80 85 93 99 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 16 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130601D*
Page 16 · cliquer pour agrandir
Page 16

E xpanded R atings — GSC130601D*

MBh 54.6 56.2 60.9 65.3 53.4 54.9 59.5 63.8 52.1 53.6 58.1 62.3 50.8 52.3 56.6 60.8 48.3 49.7 53.8 57.7 44.7 46.0 49.8 53.5 S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.38 0.89 0.80 0.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41 ∆T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 kW 3.06 3.14 3.26 3.39 3.35 3.43 3.56 3.70 3.60 3.69 3.83 3.98 3.82 3.92 4.07 4.22 4.01 4.11 4.27 4.43 4.17 4.28 4.44 4.61 Amps 12.0 12.3 12.6 13.1 12.9 13.2 13.6 14.1 14.0 14.3 14.8 15.3 14.9 15.3 15.8 16.4 15.9 16.3 16.8 17.4 16.8 17.2 17.8 18.4 HI PR 133 143 151 157 149 160 169 176 169 182 192 201 193 207 219 228 217 233 246 257 240 258 272 284 LO PR 59 63 69 73 63 67 73 78 65 69 76 81 68 73 79 85 72 76 83 89 74 79 86 92 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 17 of the Goodman Mfg Split System Air Conditioner user manual — E xpanded R atings — GSC130601D* ( cont .)
Page 17 · cliquer pour agrandir
Page 17

E xpanded R atings — GSC130601D* ( cont .)

MBh 56.6 57.7 60.4 64.4 55.3 56.3 59.0 62.9 53.9 55.0 57.6 61.4 52.6 53.6 56.2 59.9 50.0 51.0 53.4 56.9 46.3 47.2 49.4 52.7 S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.93 0.76 ∆T 27 27 25 22 27 27 25 22 27 27 25 22 27 27 26 22 26 26 25 22 24 24 24 20 kW 3.12 3.20 3.32 3.45 3.41 3.50 3.63 3.77 3.67 3.76 3.91 4.06 3.89 3.99 4.15 4.31 4.08 4.19 4.35 4.52 4.25 4.36 4.53 4.70 Amps 12.2 12.5 12.9 13.3 13.2 13.5 13.9 14.4 14.3 14.6 15.1 15.6 15.2 15.6 16.1 16.7 16.2 16.6 17.1 17.7 17.1 17.5 18.1 18.8 HI PR 135 146 154 160 152 163 172 180 173 186 196 205 197 212 223 233 221 238 251 262 244 263 278 290 LO PR 61 64 70 75 64 68 74 79 66 71 77 82 70 74 81 86 73 78 85 91 76 81 88 94 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

Page 18 of the Goodman Mfg Split System Air Conditioner user manual — Unit Coil Cooling Ratings CFM AHRI # Total¹ Sens.¹ SEER² EER³
Page 18 · cliquer pour agrandir
Page 18

AHRI R atings

Goodman Mfg Split System Air Conditioner — AHRI R atings diagram (page 18)
Fig. 3 · AHRI R atings

Unit Coil Cooling Ratings CFM AHRI # Total¹ Sens.¹ SEER² EER³

¹ BTU/h ² Seasonal Energy Efficiency Ratio; tested and rated per AHRI 210/240 ³ Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F

  • Always check the S&R plate for electrical data on the unit being installed.
  • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit.
  • EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay.
Page 19 of the Goodman Mfg Split System Air Conditioner user manual — W iring D iagram
Page 19 · cliquer pour agrandir
Page 19

W iring D iagram

Goodman Mfg Split System Air Conditioner — W iring D iagram diagram (page 19)
Fig. 4 · W iring D iagram
1. TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR

sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡

unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power

Wiring is subject to change. Always

refer to the wiring diagram or the

Page 20 of the Goodman Mfg Split System Air Conditioner user manual — H
Page 20 · cliquer pour agrandir
Page 20

D imensions

Goodman Mfg Split System Air Conditioner — D imensions diagram (page 20)
Fig. 5 · D imensions

W

D

Goodman Mfg Split System Air Conditioner — W diagram (page 20)
Fig. 6

H

A ccessories

Goodman Mfg Split System Air Conditioner — H diagram (page 20)
Fig. 7

ABK-20 Anchor Bracket Kit ▼ X ABK-21 Anchor Bracket Kit ▼ X X ASC-01 Anti-Short Cycle Kit X CSR-U-1 Hard-start Kit X CSR-U-2 Hard-start Kit X CSR-U-3 Hard-start Kit FSK01A Freeze Protection Kit 1 X LSK01A Liquid Line Solenoid Kit 2 X 0263M00019 Crankcase Heater X OT18-60A Outdoor Thermostat X

▼ Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ² Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating

compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.

  • Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2013
  • Goodman Manufacturing Company, L.P.
  • Houston, Texas
  • Printed in the USA.
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Goodman Mfg Split System Air Conditioner

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Goodman Mfg Split System Air Conditioner

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Goodman Mfg Split System Air Conditioner manuel PDF

20 pages·543 KB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…