Manuel d'utilisation / d'entretien du produit CXI du fabricant Glowworm Lighting
Aller à la page of 16
www.glow-worm.co.uk 1 www.glow-worm.co.uk To be left with the user Instructions f or Use High Efficiency Condensing Boilers Ultracom cxi.
www.glow-worm.co.uk 2 WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking, blowlamps, hot air guns etc. Do not operate electrical lights or switches either on or off. Open all doors and windows, ventilate the area.
www.glow-worm.co.uk 3 13206 G.C. No. 47-019-01 G.C. No. 47-019-02 G.C. No. 47-019-03 Ultracom 24cxi Ultracom 30cxi Ultracom 38cxi.
www.glow-worm.co.uk 4 Contents P a ge Important Information 5 Boiler Design and Clearances 6 Boiler Safety Devices 7 Servicing, Maintenance and Spare Parts 8 User Control Panel 9 Lighting the Boiler 1.
www.glow-worm.co.uk 5 Gas Safety (Installation and Use) Regulations In your own interests and that of safety, it is the Law that ALL gas appliances have been installed by a competent person in accordance with the current issue of these regulations.
www.glow-worm.co.uk 6 Boiler Design and Clearances Description These boilers are designed for use as part of a sealed water central heating system with fully pumped circulation. The pump, expansion vessel and associated safety devices are all fitted within the boiler.
www.glow-worm.co.uk 7 Boiler Safety Devices Boiler Shutdown The boiler software is designed to recognise the potential for an overheat lockout and will shutdown before this happens.
www.glow-worm.co.uk 8 General Note Servicing/maintenance should be carried out by a competent person in accordance with the rules in force in the countries of destination.
www.glow-worm.co.uk 9 User Contr ol Panel General Description The User Control panel consists of three toggle buttons, a reset button and display, which will indicate with symbols the status of the boiler, refer to diagram 2.
www.glow-worm.co.uk 10 Initial Lighting Remove the cover plate, refer to the fault finding section on page 15 and diagram 8. Check that all isolating valves and the gas service cock on the appliance are open and that water flows from the hot water taps, then close taps, refer diagram 3.
www.glow-worm.co.uk 11 Adjusting T emperatur e 13178 Diagram 4 13179 Domestic Hot Water Central Heating Domestic Hot Water Domestic hot water has priority over central heating. The temperature is factory preset to the minimum 40 O C, but can be adjusted to a maximum of 62 O C as required, refer to diagram 4.
www.glow-worm.co.uk 12 To set the clock, refer to diagram 5. Setting the 24 hour Clock Diagram 5 13177 STEP 1 STEP 2 MODE PROG MODE PROG STEP 3 Press and hold "PROG" 5 secs. the "hours" symbol will flash. Press "PROG" to confirm.
www.glow-worm.co.uk 13 24hr Timed Central Heating Factory preset timed intervals are:- ON 6.00 - OFF 8.00 ON 16.00 - OFF 23.00 Setting the Pr ogrammer Diagram 6 13468 To alter the times to suit your requirments, follow "Steps" 1 to 4 MODE PROG Flashing cursor .
www.glow-worm.co.uk 14 Advancing the Pr ogrammer Advancing the timed central heating programmer ON /OFF times This function will only work when the appliance is in timed operating mode, "Clock symbol". Refer to diagram 2. The activated/deactivated segments will flash for 5 seconds.
www.glow-worm.co.uk 15 Double Check Inlet V alve V AL VES SHOWN CLOSED Appliance fails to light The LCD will display a flashing 'F' and code number, press the reset button on the control panel, see diagram 2. If the display shows a flashing pressure of 0.
www.glow-worm.co.uk 16 Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions. Glow-worm, Nottingham Road, Belper, Derbyshire.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Glowworm Lighting CXI c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Glowworm Lighting CXI - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Glowworm Lighting CXI, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Glowworm Lighting CXI va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Glowworm Lighting CXI, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Glowworm Lighting CXI.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Glowworm Lighting CXI. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Glowworm Lighting CXI ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.