Room
Air Conditioners
Safety Instructions 2, 3
Cool Only: AJCM 08, 10 ACD* AJCM 10, 12 DCD* AJCQ 06 LCD* AJCQ 08, 10, 12 ACD* AJCQ 09, 10, 12 DCD*
Care and Cleaning Air Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10
Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional) 16-21
Troubleshooting Tips 22 Normal Operating Sounds 22
For a Spanish version of this manual, visit our Website at GEAppliances.com.
Consumer Support Consumer Support Back Cover Warranty 23
Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet GEAppliances.com. Française
*ENERGY STAR® labeled product
For a French version of this manual, visit our Website at GEAppliances.com.
Pour une version française de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse GEAppliances.com.
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Write the model and serial numbers here:
Serial # ______________________
Find these numbers on a label on the front of the base pan behind the front grille.


Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
of the 230/208-volt models.
of an extension cord.
it is absolutely necessary that it be a UL- listed, 14-gauge, 3-wire grounding-type appliance extension cord having a grounding-type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
of an adapter plug.
codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
DO NOT USE the air conditioner until a proper ground has been established.
to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Appearance may vary.
Remote Control
Lights beside the touch pads on the air conditioner
ON/OFF Turns air conditioner on and off.
To cancel the On Timer, press the ON pad until the display time disappears.
Display Displays the temperature setting. Displays hours when setting the timer.
OFF—When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.
MODE On the remote control, use to set the air conditioner to COOL or FAN mode.
To cancel the Off Timer, press the OFF pad until the display time disappears.
On the air conditioner controls, use to set COOL or FAN mode at HIGH, MED or LOW fan speed. Indicator lights on the air conditioner controls will show the mode and fan speed selected.
SLEEP Press to set the air conditioner to run for 8 hours before it automatically returns to the previous setting.
TEMP Increase + /Decrease – Pads Use to set temperature when in COOL mode.
When the sleep timer is set, the set temperature will automatically increase 2°F after the second hour then 1°F each hour over the next two hours.
Fan Speeds (Remote control only) Use to set the fan speed at LOW, MED or HIGH.
To cancel the sleep mode, press the MODE pad or the SLEEPpad a second time. Remote Control Signal Receiver
TIMER ON—When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.
control at the signal receiver on the air conditioner.
conditioner and the remote control that could block the signal.
of up to 21 feet.
correctly—see the Care and Cleaning section.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Set the thermostat at a higher number and the indoor air will become warmer.
For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.
Use the FAN mode to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a temperature setting will not be displayed.
Press FAN pad. Press LOW, MED or HIGH pads to set desired fan speed.
Press the MODE pad until the FAN indicator light is lit and the LOW, MED or HIGH indicator light is lit for the desired fan speed.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Appearance may vary.
Remote Control
Lights beside the touch pads on the air conditioner
control panel indicate the selected settings.
ON/OFF Turns air conditioner on and off.
TIMER ON—When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.
Display Displays the temperature setting. Displays hours when setting the timer.
MODE On the air conditioner controls, use to set COOL, HEAT or FAN mode. Indicator lights on the air conditioner controls will show the mode selected. TEMP Increase + /Decrease – Pads Use to set temperature when in COOL or HEAT mode.
To cancel the On Timer, press the ON pad until the display time disappears.
OFF—When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.
To cancel the Off Timer, press the OFF pad until the display time disappears.
FAN Speeds Use to set the fan speed at LOW or HIGH. Indicator lights will show the speed selected.
remote control at the signal receiver on the air conditioner.
conditioner and the remote control that could block the signal.
of up to 21 feet.
correctly—see the Care and Cleaning section.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Set the thermostat at a higher number and the indoor air will become warmer.
For Normal Cooling—Select the COOL mode and HIGH fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.
Set the thermostat at a lower number and the indoor air will become cooler.
For Normal Heating—Select the Heat mode and HIGH fan with a middle set temperature.
For Maximum Heating—Select the HEAT mode and HIGH fan with a higher set temperature.
For Quieter and Nighttime Heating—Select the HEAT mode and LOW fan with a middle set temperature.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a higher number and the indoor air will become warmer.
Use the FAN to provide air circulation and filtering without cooling or heating. Since fan only settings do not provide cooling or heating, a temperature setting will not be displayed.
Press FAN pad. Press LOW or HIGH pads to set desired fan speed.
Press the MODE pad until the FAN indicator light is lit and the LOW or HIGH indicator light is lit for the desired fan speed.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
The vent control is located behind the front grille on the right side of the air discharge area. When CLOSED, only the air inside the room will be circulated and conditioned. When OPEN, the vent allows outdoor fresh air exchange.
The unit leaves the factory set at the CLOSE position.
To open or close the vent: 1. Remove the front grille. 2. Remove the vent card screw. 3. Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.
OPEN position (Mesh end toward back)
CLOSE position (Mesh end toward front)
When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the compressor. When this switch is disabled (DOWN), it allows the indoor fan to run continuously. The default setting is down (continuous).
Fan Cycle/Continuous - Cool
Fan Cycle/Continuous - Heat (on some models)
Fan Cycle/Continuous - Heat (on some models)
When this switch is enabled (UP), it allows the indoor fan to run continuously with the heater operation. When this switch is disabled (DOWN), it allows the indoor fan to cycle on/off. The default setting is down (cyclic).
Class 2 - Remote Thermostat (on some models)
When this switch is enabled (UP), it allows the unit to operate with a Class 2 Remote Control Wall Thermostat. The unit controls are disabled. The default setting is down (disabled).
Class 2 (on some models)

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Terminal Connections Remote Thermostat - Class 2 (on some models)
The controls are located under a plastic cover behind the front grille.
Remove the front grille. See the Front Grille section of Care and Cleaning.
Remove the screws securing the plastic cover over the wiring connections. Set aside screws and plastic cover.
To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.
After all desired connections have been made, replace the plastic cover and front grille.
The owner is responsible for making all connections and setting the appropriate dip switches.
When connected, the unit will be controlled by a remote thermostat.
If using a digital/electronic wall thermostat, ensure it is compatible with 24 VAC signal. See the Installation Instructions for the wall thermostat. NOTICE: Damage to a wall thermostat or to the electronics can result from improper connections. Special care must be used in connecting the wires. No line voltage connections should be made to any circuit. Isolate all wires in building from line voltage.
location under front · grille

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Care and cleaning of the air conditioner.
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.
The front grille can be removed for more thorough cleaning and to locate the model and serial numbers on the front of the base pan.
To remove:
To replace:
Hook the tabs on the front grille even with the tabs on the case and snap into place.
Replace the screws and filter.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
To maintain optimum performance, clean the filter at least every 30 days.
To remove the air filter, on other models:
Pull it down.
Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.
Turn the air conditioner off before cleaning.
The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow.
To replace the air filter:
Replace the clean filter by pushing it back into place.
Keeping the air filter clean will:
To clean the air filters:
To remove the air filter, on some models:
Carefully pull the tab forward, up and out.
Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.
Remove the battery cover by sliding it according to the arrow direction.
Insert new batteries making sure that the (+) and (–) of battery are installed correctly.
rechargeable batteries.
if the system is not going to be used for a long time. 3
Reattach the cover by sliding it back into position.

BEFORE YOU BEGIN
ELECTRICAL REQUIREMENTS (cont.)
Read these instructions completely and carefully.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
IMPORTANT! GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.
ELECTRICAL REQUIREMENTS
J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart on the next page for the proper kit.
What brand air conditioner will you be replacing?
What are the dimensions of the wall case currently in use? What is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use? Frequently, the J-model adapter kit will apply to another brand model “series” or specific vintage. In these cases, you need the chassis model number and/or the wall case or “type” number to confirm the use of the correct adapter kit. What type of outdoor grille is used with the current wall case? There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow.
Some models require a 115/120-volt a.c., 60-Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Do not change the plug on the power cord of this air conditioner. Aluminum house wiring may present special problems—consult a qualified electrician.


Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TESTbutton and then the RESETbutton.
If the TESTbutton does not trip or if the RESETbutton will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

USE GE KIT NUMBER: FOR: DESCRIPTION: RAB46A, 47A Use these kits for all GE Standard wall case for “J” model chassis. RAG13 stamped & 48A models and other brands aluminum exterior grille included. Remove the existing case not listed and replace. RAK65A1 All GE Models Kit for window installation. RAK56A100 GE RAB13, 14 & 15 Fits all GE wall cases 26″W x 18″H x 24″D. (ACLB & RCL Chassis) RAK1072 Hotpoint ACXB10 & 11 Adapts an older Hotpoint wall case to a “J” model chassis. (ACTB Chassis) Fits Hotpoint wall cases 253⁄ 4″W x 167⁄ 8″H x 185⁄ 8″D. RAK1082 Whirlpool Type 23W Adapts Whirlpool wall case to a “J” model chassis. Wall Case Fits Whirlpool wall cases 257⁄ 8″W x 161⁄ 2″H x 231⁄ 8″D. RAK1102 GE RAB30 Adapts GE wall case to a “J” model chassis. (“F” models) Fits the RAB 30 wall case 26″W x 18″H x 24″D. RAK123A64 Fedders Wall Case “A” Adapts Fedders wall case to a “J” model chassis. Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄ 4″D. RAK126 Westinghouse Wall Case Adapts Westinghouse wall case to a “J” model chassis. (Type 2626D73H01) Fits Westinghouse wall cases 257⁄ 8″W x 157⁄ 16″H x 16″D. RAB46, 47 & 48 Use these kits for all Standard wall case for “J” model chassis. RAG13 stamped other brands not listed. aluminum exterior grille included. Remove the existing case and replace. RAK690 RAB36, 37, 38, 46, 47 or 48 If you attach a custom architectural outdoor grille, use this kit (J-Chassis) to ensure proper airflow. RAG13 RAB36, 37, 38, 46, 47 or 48 Standard aluminum exterior grille (included with RAB46, 47 (J-Chassis) and 48 wall cases). RAG14E RAB36, 37, 38, 46, 47 or 48 Architectural louvered exterior grille. (J-Chassis)


REMOVE LOCKING PLATE ON FRONT LEFT SIDE 1 REINSTALL LOCKING PLATE WITH TAB BEHIND WALL CASE FLANGE. TIGHTEN SCREW Locking
ATTACH FRONT GRILLE An opening for the power cord is on the bottom of the front grille.
CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure.

Read these instructions completely and carefully.
PREPARE OPENING IN WALL Make certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle. The cord length for the 115-volt models is 72″ to the right and 47″ to the left. For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left.
SUPPORT REQUIREMENTS FOR AIR CONDITIONER Mortar between the case and the brick wall around the case may be undercut at about 45° for improved caulking.
SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner wall case may be installed with 1/4″ min. extension out from the inside wall or with 1/4″ min. extension out from the outside wall. The finished sides of the opening should be structural wall members. Lintel – Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel. Flashing – Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.
Caulking (on all 4 sides on the outside
Trim molding (if desired)
and inside of the case)
Caulking (above and below the flashing)
1/4″ min. extension inside the wall from

Case side gasket (2)
2 angles (left and right
Foam top window gasket
A
Filler Panels Cut panels and discard center piece
(holes are on the left)
(holes are on the right)
Type C (painted) (6)
17″ min.
31″ to 43″ (With filler panels)
261⁄4″ min. (Without filler panels)
Window opening dimensions are for
a standard double-hung window.

STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.
1/2″ higher than frame
Remove all shipping pads (if present) inside the air conditioner next to the compressor.
Remove the front grille. See the Care and Cleaning section. Find the locking plate located on the front left side.
Remove the screw and the locking plate to unlock the air conditioner.
Remove shipping pads (if present)
Remove the rear grille that is taped to the back of the case. Remove the packet of screws taped to the back of the grille. While holding the grille at a 45° angle, insert it into the clips at the top of the case and push the bottom in. Keep slight upward pressure on the grille until it fits flush with the bottom of the case.
Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case.
If attaching the grille from the outside of the case, use the 2 long screws.
If attaching the grille from the inside of the case, use the 2 short screws.
Pull the bottom corners of the air conditioner and slide it out of the case.
Insert the 2 long screws
Insert the 2 short screws

Measure 123⁄8″ from the centerline on both sides for the sill support brackets.
Mark the centerline of the stool. Measure from the centerline 133⁄8″ on both sides for the panel cuts.
133⁄8″
133⁄8″ 123⁄8″ 123⁄8″
Turn the bolts and tighten the lock nuts to make the sill supports level or tilt down 1/8″ to the outside. Line up the “V” notch with 123⁄8″ marks. Drill pilot holes and attach the sill supports.
Assemble the sill supports. Do not fully tighten the spacer mounting screws at this time.
Spacer mounting screws Type (A)
Large washer (for use with wood sills)
Offset sill (such as brick or stone)
Before attaching the sill supports, place them on the window stool. Select the spacer position that will place the spacer near the outermost point on the sill. Tighten the spacer mounting screws.
Screws are in position

Measure from the edge of the panel marks (see Prepare the Window) to the inside of the window track on each side (A and B).
Type C (painted screws)
133⁄8″ 133⁄8″
Width of the air
conditioner (panel marks) Left side
Install the panels in the window. Place the spring clips 3″ from the top and the bottom. Squeeze and push the clips to fit in the window track and the tab into the sill support.
Mark the A and B measurements on each side of the filler panel board. Cut the panels and discard the center piece. Note position of the notches.
A
(holes are on the right)
(holes are on the left)
Cut panels and discard center piece
Hook the tab into the sill support
Put together the panel assemblies. Remove the paper backing from the case-side gasket and attach it to the angle. Push a pencil point through the gaskets to locate the holes in the angles.

INSTALL CASE IN WINDOW
With the window closed, mark where the window sash meets the case.
Peel off the backing from the bottom window gasket.
Peel off the backing from the case top gasket.
G
Place the gasket on the stool and over the brackets, even with the rear edge, sticky side down.
Hold on to the case, open the window and place the gasket along the mark on the case.
Put the gasket on top of the case where the window will close.
Carefully slide the empty case into the window until the holes in the case line up with the holes in the panel angles.
Place the vinyl window gasket over the case top gasket. Insert the panel tabs through the slits in the gasket. Cut the gasket on each side to the width of the window.
Lower the window so it fits behind the panel tabs. Insert the 4 type A screws through the holes in the case and into the panel angles, 2 on each side.
Close the window tightly on the vinyl gasket. Bend the gasket forward to expose the panel tabs. Drill pilot holes into the window sash.
Attach the panel tab to the window on each side with a type D screw.


Cut the foam top window gasket to the window width.
Attach the window locking bracket with 1 type E screw.
Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
Reinstall the locking plate with the tab behind the wall case flange. Tighten the screw.
Carefully slide the air conditioner back into the case.
Reattach the front grille. An opening for the power cord is on the bottom of the front grille.
Fill holes and cracks with caulking provided by the installer.
Attach the power cord to the base pan with the clamp.

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.
Problem Possible Causes What To Do
Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.
The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cooling coils have iced up. • See “Air conditioner freezing up” below.
Air conditioner Ice blocks the airflow • Set the controls at HIGH FAN or HIGH COOL and set the freezing up and stops the air conditioner thermostat to a higher temperature to allow the ice to melt. from cooling the room.
The remote control is The batteries are inserted • Check the position of the batteries. They should be not working incorrectly. inserted correctly.
The batteries may be dead. • Replace the batteries.
Water drips outside Hot, humid weather. • This is normal.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air • This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
does not.
compressor cycles on and off.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Air Conditioner Warranty.
All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line visit us at GEAppliances.com, or call 800.GE.CARES (800.432.2737). For service in Canada, contact Gordon Williams Corp. at 1.888.209.0999. Please have serial number and model number availa ble when calling for service.
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor original purchase and related service to replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.
the product.
breakers.
have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
protected.
supply voltage, accident, fire, floods or acts of God.
defects with this air conditioner.
the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
unit to a location where it is accessible for service by an individual technician.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Consumer Support.

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.
Printed in China
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.