Page 1 of the GE AJEQ 08 user manual — TINSEA568JBRZ 49-7597-2 05-09 JR
Page 1 · cliquer pour agrandir
Page 1

GEAppliances.com

Owner’s Manual and Installation Instructions

Room

Air Conditioners

Safety Instructions 2, 3

Cool Only: AJCM 08, 10 ACD* AJCM 10, 12 DCD* AJCQ 06 LCD* AJCQ 08, 10, 12 ACD* AJCQ 09, 10, 12 DCD*

Operating Instructions 4-9

Care and Cleaning Air Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10

Heat/CoolAJEM 12 DCD AJEQ 06 LCD AJEQ 08 ACD AJEQ 09, 10, 12 DCD

Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional) 16-21

Español

Troubleshooting Tips 22 Normal Operating Sounds 22

For a Spanish version of this manual, visit our Website at GEAppliances.com.

Consumer Support Consumer Support Back Cover Warranty 23

Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet GEAppliances.com. Française

*ENERGY STAR® labeled product

For a French version of this manual, visit our Website at GEAppliances.com.

Pour une version française de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse GEAppliances.com.

As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.

Write the model and serial numbers here:

Model #

Serial # ______________________

Find these numbers on a label on the front of the base pan behind the front grille.

TINSEA568JBRZ 49-7597-2 05-09 JR

Page 2 of the GE AJEQ 08 user manual — Safety Instructions
Page 2 · cliquer pour agrandir
Page 2
Safety InstructionsIMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS WARNING! manufacturer and not repaired. Do not Risk of electric shock. use a cord that shows cracks or abrasion Can cause injury or death. For your safety, damage along its length or at either the the information in this manual must be followed plug or connector end. to minimize the risk of fire, electric shock or personal injury. ■ Turn OFF and unplug your air conditioner before making any repairs or cleaning. ■ Use this appliance only for its intended purpose as described in this Owner’s NOTE: We strongly recommend that any Manual. servicing be performed by a qualified individual. ■This air conditioner must be properly installed in accordance with the Installation ■ For your safety…do not store or use Instructions before it is used. combustible materials, gasoline or other flammable vapors or liquids in the vicinity ■Never unplug your air conditioner by pulling of this or any other appliance. on the power cord. Always grip plug firmly and pull straight out from the receptacle. ■ All air conditioners contain refrigerants, which under federal law must be removed ■ Replace immediately all electric service prior to product disposal. If you are getting cords that have become frayed or rid of an old product with refrigerants, check otherwise damaged. A damaged power with the company handling disposal about supply cord must be replaced with a new what to do. power supply cord obtained from the HOW TO CONNECT ELECTRICITY WARNING! ■Where a 2-prong wall outlet is encountered, Risk of electric shock. it is your personal responsibility and Can cause injury or death. This appliance must obligation to have it replaced with a be properly grounded. Do not, under any properly grounded 3-prong wall outlet. circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, WARNING! Risk of electric shock. this appliance must be properly grounded. Can cause injury or death. ■The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates ■The air conditioner should always be with a standard 3-prong (grounding) wall plugged into its own individual electrical outlet to minimize the possibility of electric outlet which has a voltage rating that shock hazard from this appliance. matches the rating plate. This provides ■Have the wall outlet and circuit checked the best performance and also prevents by a qualified electrician to make sure overloading house wiring circuits which the outlet is properly grounded. could cause a fire hazard from overheated wires. ■Power cord may include a current interrupter device. A test and reset button is ■See the Installation Instructions, Electrical provided on the plug case. The device should Requirements section for specific electrical be tested on a periodic basis by first pressing connection requirements. the TESTbutton and then the RESETbutton. If the TESTbutton does not trip or if the RESETbutton will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. SAVE THESE INSTRUCTIONS 2 Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Page 3 of the GE AJEQ 08 user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 3 · cliquer pour agrandir
Page 3

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GEAppliances.com

USE OF EXTENSION CORDS— 115-Volt models only

  • DO NOT use an extension cord with any

of the 230/208-volt models.

of an extension cord.

  • If you must use an extension cord,

it is absolutely necessary that it be a UL- listed, 14-gauge, 3-wire grounding-type appliance extension cord having a grounding-type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

USE OF ADAPTER PLUGS— 115-Volt models only

  • When disconnecting the power cord from

the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

of an adapter plug.

  • If you must use an adapter, where local

codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

  • If the adapter ground terminal breaks,

DO NOT USE the air conditioner until a proper ground has been established.

  • Attaching the adapter ground terminal

to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

  • The larger slot in the adapter must be

aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 4 of the GE AJEQ 08 user manual — Remote Control
Page 4 · cliquer pour agrandir
Page 4

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

About the controls on the air conditioner—Cool Only Models

Appearance may vary.

Air Conditioner Controls

Remote Control

Lights beside the touch pads on the air conditioner

control panel indicate the selected settings. Controls

ON/OFF Turns air conditioner on and off.

To cancel the On Timer, press the ON pad until the display time disappears.

Display Displays the temperature setting. Displays hours when setting the timer.

OFF—When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.

MODE On the remote control, use to set the air conditioner to COOL or FAN mode.

To cancel the Off Timer, press the OFF pad until the display time disappears.

On the air conditioner controls, use to set COOL or FAN mode at HIGH, MED or LOW fan speed. Indicator lights on the air conditioner controls will show the mode and fan speed selected.

SLEEP Press to set the air conditioner to run for 8 hours before it automatically returns to the previous setting.

TEMP Increase + /Decrease – Pads Use to set temperature when in COOL mode.

When the sleep timer is set, the set temperature will automatically increase 2°F after the second hour then 1°F each hour over the next two hours.

Fan Speeds (Remote control only) Use to set the fan speed at LOW, MED or HIGH.

To cancel the sleep mode, press the MODE pad or the SLEEPpad a second time. Remote Control Signal Receiver

TIMER ON—When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.

Remote Control

  • To ensure proper operation, aim the remote
  • Make sure nothing is between the air

control at the signal receiver on the air conditioner.

conditioner and the remote control that could block the signal.

  • The remote control signal has a range
  • Make sure batteries are fresh and installed

of up to 21 feet.

correctly—see the Care and Cleaning section.

Page 5 of the GE AJEQ 08 user manual — FAN MODE
Page 5 · cliquer pour agrandir
Page 5

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GEAppliances.com

COOL MODE

Set the thermostat at a higher number and the indoor air will become warmer.

1. Press COOL pad.
2. Press LOW , MED or HIGH pads to set desired fan speed.
3. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.

For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.

1. Press the MODE pad until the COOL indicator light is lit and the LOW , MED or HIGH indicator light is lit for the desired fan speed.

For Quieter and Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.

2. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.

FAN MODE

Use the FAN mode to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a temperature setting will not be displayed.

Press FAN pad. Press LOW, MED or HIGH pads to set desired fan speed.

Press the MODE pad until the FAN indicator light is lit and the LOW, MED or HIGH indicator light is lit for the desired fan speed.

Show 5 more labels / short text on this page
Remote Control · Cooling Descriptions · Control Panel · Remote Control · Control Panel
Page 6 of the GE AJEQ 08 user manual — Remote Control
Page 6 · cliquer pour agrandir
Page 6

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

About the controls on the air conditioner—Heat/Cool Models

Appearance may vary.

Air Conditioner Controls

Remote Control

Lights beside the touch pads on the air conditioner

control panel indicate the selected settings.

Controls

ON/OFF Turns air conditioner on and off.

TIMER ON—When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.

Display Displays the temperature setting. Displays hours when setting the timer.

MODE On the air conditioner controls, use to set COOL, HEAT or FAN mode. Indicator lights on the air conditioner controls will show the mode selected. TEMP Increase + /Decrease – Pads Use to set temperature when in COOL or HEAT mode.

To cancel the On Timer, press the ON pad until the display time disappears.

OFF—When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.

To cancel the Off Timer, press the OFF pad until the display time disappears.

FAN Speeds Use to set the fan speed at LOW or HIGH. Indicator lights will show the speed selected.

Remote Control Signal Receiver

Remote Control

  • To ensure proper operation, aim the
  • Make sure nothing is between the air

remote control at the signal receiver on the air conditioner.

conditioner and the remote control that could block the signal.

  • The remote control signal has a range
  • Make sure batteries are fresh and installed

of up to 21 feet.

correctly—see the Care and Cleaning section.

Page 7 of the GE AJEQ 08 user manual — FAN
Page 7 · cliquer pour agrandir
Page 7

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GEAppliances.com

COOL MODE

Set the thermostat at a higher number and the indoor air will become warmer.

1. Press COOL pad.
2. Press LOW or HIGH pads to set desired fan speed.
3. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

For Normal Cooling—Select the COOL mode and HIGH fan with a middle set temperature.

1. Press the MODE pad until the COOL indicator light is lit.
2. Press the FAN pad until HIGH or LOW indicator light is lit for desired fan speed.

For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.

3. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

For Quieter and Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.

HEAT MODE

Set the thermostat at a lower number and the indoor air will become cooler.

1. Press HEAT pad.
2. Press LOW or HIGH pads to set desired fan speed.
3. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

For Normal Heating—Select the Heat mode and HIGH fan with a middle set temperature.

1. Press the MODE pad until the HEAT indicator light is lit.
2. Press the FAN pad until HIGH or LOW indicator light is lit for desired fan speed.

For Maximum Heating—Select the HEAT mode and HIGH fan with a higher set temperature.

For Quieter and Nighttime Heating—Select the HEAT mode and LOW fan with a middle set temperature.

3. Press the INCREASE + / DECREASE – pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a higher number and the indoor air will become warmer.

FAN

Use the FAN to provide air circulation and filtering without cooling or heating. Since fan only settings do not provide cooling or heating, a temperature setting will not be displayed.

Press FAN pad. Press LOW or HIGH pads to set desired fan speed.

Press the MODE pad until the FAN indicator light is lit and the LOW or HIGH indicator light is lit for the desired fan speed.

Show 8 more labels / short text on this page
Remote Control · Cooling Descriptions · Control Panel · Remote Control · Heating Descriptions · Control Panel · Remote Control · Control Panel
Page 8 of the GE AJEQ 08 user manual — Fan Cycle/Continuous - Cool
Page 8 · cliquer pour agrandir
Page 8

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

About the controls on the air conditioner

Vent Control

The vent control is located behind the front grille on the right side of the air discharge area. When CLOSED, only the air inside the room will be circulated and conditioned. When OPEN, the vent allows outdoor fresh air exchange.

The unit leaves the factory set at the CLOSE position.

To open or close the vent: 1. Remove the front grille. 2. Remove the vent card screw. 3. Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.

OPEN position (Mesh end toward back)

CLOSE position (Mesh end toward front)

Horizontal louvers Remove the front grille on the front grille let to adjust the vertical you control the air louvers side-to-side direction up and down. to direct the air left or right. Horizontal louvers Remove the front grille on the front grille let to adjust the vertical you control the air louvers side-to-side direction up and down. to direct the air left or right. Auxiliary Controls – Dip Switches (location varies by model) The auxiliary dip switch controls are located behind the room cabinet—as shown in this figure. The owner is responsible for checking switches Fan Cycle/Continuous - Cool and ensuring they are in the desired position. Fan Cycle/Continuous - Heat (on some models Class 2 (on some models) No function (reserved for future use)xiliary Controls – Dip Switches (locationvaries by model) The auxiliary dip switch controls are located behind the room cabinet—as shown in this figure. The owner is responsible for checking switches and ensuring they are in the desired position.

Fan Cycle/Continuous - Cool

When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the compressor. When this switch is disabled (DOWN), it allows the indoor fan to run continuously. The default setting is down (continuous).

Fan Cycle/Continuous - Cool

Fan Cycle/Continuous - Heat (on some models)

Fan Cycle/Continuous - Heat (on some models)

When this switch is enabled (UP), it allows the indoor fan to run continuously with the heater operation. When this switch is disabled (DOWN), it allows the indoor fan to cycle on/off. The default setting is down (cyclic).

Class 2 - Remote Thermostat (on some models)

When this switch is enabled (UP), it allows the unit to operate with a Class 2 Remote Control Wall Thermostat. The unit controls are disabled. The default setting is down (disabled).

Class 2 (on some models)

Show 4 more labels / short text on this page
Locating hole · Locating hole · Screw hole · Screw hole
Page 9 of the GE AJEQ 08 user manual — 1 Terminal connections
Page 9 · cliquer pour agrandir
Page 9

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GEAppliances.com

Terminal Connections Remote Thermostat - Class 2 (on some models)

The controls are located under a plastic cover behind the front grille.

1 Terminal connections

Remove the front grille. See the Front Grille section of Care and Cleaning.

Remove the screws securing the plastic cover over the wiring connections. Set aside screws and plastic cover.

To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.

After all desired connections have been made, replace the plastic cover and front grille.

The owner is responsible for making all connections and setting the appropriate dip switches.

When connected, the unit will be controlled by a remote thermostat.

If using a digital/electronic wall thermostat, ensure it is compatible with 24 VAC signal. See the Installation Instructions for the wall thermostat. NOTICE: Damage to a wall thermostat or to the electronics can result from improper connections. Special care must be used in connecting the wires. No line voltage connections should be made to any circuit. Isolate all wires in building from line voltage.

location under front · grille

Page 10 of the GE AJEQ 08 user manual — Front Grille
Page 10 · cliquer pour agrandir
Page 10

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Front Grille

The front grille can be removed for more thorough cleaning and to locate the model and serial numbers on the front of the base pan.

3. Pull the grille out from the bottom and lift up from the tabs on the top of the case.

To remove:

1. Pull the filter out. 2. Remove the two grille screws.

To replace:

Hook the tabs on the front grille even with the tabs on the case and snap into place.

Replace the screws and filter.

Show 6 more labels / short text on this page
Grille · Tab · On some models · On some models · Grille · Tab
Page 11 of the GE AJEQ 08 user manual — NOTES:
Page 11 · cliquer pour agrandir
Page 11

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GEAppliances.com

To maintain optimum performance, clean the filter at least every 30 days.

Air Filter

To remove the air filter, on other models:

FRONT FRONT

Pull it down.

Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.

Turn the air conditioner off before cleaning.

The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow.

To replace the air filter:

Replace the clean filter by pushing it back into place.

Keeping the air filter clean will:

  • Decrease cost of operation.
  • Save energy.
  • Prevent clogged heat exchanger coils.
  • Reduce the risk of premature component failure.

To clean the air filters:

  • Vacuum off the heavy soil.
  • Run water through the filters.
  • Dry thoroughly before replacing.

To remove the air filter, on some models:

Carefully pull the tab forward, up and out.

Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.

How to Insert the Batteries in the Remote Control

Remove the battery cover by sliding it according to the arrow direction.

NOTES:

  • Use 2 AAA (1.5 volt) batteries. Do not use

Insert new batteries making sure that the (+) and (–) of battery are installed correctly.

rechargeable batteries.

  • Remove the batteries from the remote control

if the system is not going to be used for a long time. 3

Reattach the cover by sliding it back into position.

Page 12 of the GE AJEQ 08 user manual — D
Page 12 · cliquer pour agrandir
Page 12

Installation Air Conditioner Instructions

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

ELECTRICAL REQUIREMENTS (cont.)

Read these instructions completely and carefully.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

  • IMPORTANT — Save these instructions for local inspector’s use.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.

IMPORTANT! GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.

J-MODEL QUALIFYING QUESTIONS

ELECTRICAL REQUIREMENTS

J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart on the next page for the proper kit.

B A

What brand air conditioner will you be replacing?

What are the dimensions of the wall case currently in use? What is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use? Frequently, the J-model adapter kit will apply to another brand model “series” or specific vintage. In these cases, you need the chassis model number and/or the wall case or “type” number to confirm the use of the correct adapter kit. What type of outdoor grille is used with the current wall case? There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow.

Some models require a 115/120-volt a.c., 60-Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Do not change the plug on the power cord of this air conditioner. Aluminum house wiring may present special problems—consult a qualified electrician.

D

Page 13 of the GE AJEQ 08 user manual — GE KIT NUMBERS
Page 13 · cliquer pour agrandir
Page 13
GE AJEQ 08 — Before You Begin diagram (page 13)
Fig. 1 · Before You Begin

Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TESTbutton and then the RESETbutton.

If the TESTbutton does not trip or if the RESETbutton will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

GE AJEQ 08 — Before You Begin diagram (page 13)
Fig. 2 · Before You Begin

GE KIT NUMBERS

USE GE KIT NUMBER: FOR: DESCRIPTION: RAB46A, 47A Use these kits for all GE Standard wall case for “J” model chassis. RAG13 stamped & 48A models and other brands aluminum exterior grille included. Remove the existing case not listed and replace. RAK65A1 All GE Models Kit for window installation. RAK56A100 GE RAB13, 14 & 15 Fits all GE wall cases 26″W x 18″H x 24″D. (ACLB & RCL Chassis) RAK1072 Hotpoint ACXB10 & 11 Adapts an older Hotpoint wall case to a “J” model chassis. (ACTB Chassis) Fits Hotpoint wall cases 253⁄ 4″W x 167⁄ 8″H x 185⁄ 8″D. RAK1082 Whirlpool Type 23W Adapts Whirlpool wall case to a “J” model chassis. Wall Case Fits Whirlpool wall cases 257⁄ 8″W x 161⁄ 2″H x 231⁄ 8″D. RAK1102 GE RAB30 Adapts GE wall case to a “J” model chassis. (“F” models) Fits the RAB 30 wall case 26″W x 18″H x 24″D. RAK123A64 Fedders Wall Case “A” Adapts Fedders wall case to a “J” model chassis. Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄ 4″D. RAK126 Westinghouse Wall Case Adapts Westinghouse wall case to a “J” model chassis. (Type 2626D73H01) Fits Westinghouse wall cases 257⁄ 8″W x 157⁄ 16″H x 16″D. RAB46, 47 & 48 Use these kits for all Standard wall case for “J” model chassis. RAG13 stamped other brands not listed. aluminum exterior grille included. Remove the existing case and replace. RAK690 RAB36, 37, 38, 46, 47 or 48 If you attach a custom architectural outdoor grille, use this kit (J-Chassis) to ensure proper airflow. RAG13 RAB36, 37, 38, 46, 47 or 48 Standard aluminum exterior grille (included with RAB46, 47 (J-Chassis) and 48 wall cases). RAG14E RAB36, 37, 38, 46, 47 or 48 Architectural louvered exterior grille. (J-Chassis)

Page 14 of the GE AJEQ 08 user manual — REMOVE ALL SHIPPING PADS (IF PRESENT) INSIDE AIR CONDITIONER NEXT TO COMPRESSOR
Page 14 · cliquer pour agrandir
Page 14
GE AJEQ 08 — Installing a J-Model in an Existing Wall Case diagram (page 14)
Fig. 3 · Installing a J-Model in an Existing Wall Case

REMOVE LOCKING PLATE ON FRONT LEFT SIDE 1 REINSTALL LOCKING PLATE WITH TAB BEHIND WALL CASE FLANGE. TIGHTEN SCREW Locking

REMOVE ALL SHIPPING PADS (IF PRESENT) INSIDE AIR CONDITIONER NEXT TO COMPRESSOR

ATTACH FRONT GRILLE An opening for the power cord is on the bottom of the front grille.

CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure.

Page 15 of the GE AJEQ 08 user manual — INSTALLING THROUGH THE WALL
Page 15 · cliquer pour agrandir
Page 15

INSTALLING THROUGH THE WALL

Read these instructions completely and carefully.

PREPARE OPENING IN WALL Make certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle. The cord length for the 115-volt models is 72″ to the right and 47″ to the left. For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left.

SUPPORT REQUIREMENTS FOR AIR CONDITIONER Mortar between the case and the brick wall around the case may be undercut at about 45° for improved caulking.

SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner wall case may be installed with 1/4″ min. extension out from the inside wall or with 1/4″ min. extension out from the outside wall. The finished sides of the opening should be structural wall members. Lintel – Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel. Flashing – Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.

Caulking (on all 4 sides on the outside

Trim molding (if desired)

and inside of the case)

Caulking (above and below the flashing)

1/4″ min. extension inside the wall from

Show 12 more labels / short text on this page
Inside · Top of case · Outside · Caulking · Undercut mortar · Brick veneer · Lintel angle · (if required) · Plaster line · Room side · Flashing (drip rail) · the trim molding
Page 16 of the GE AJEQ 08 user manual — B
Page 16 · cliquer pour agrandir
Page 16

WINDOW INSTALLATION—OPTIONAL

Case side gasket (2)

2 angles (left and right

Foam top window gasket

B

A

Filler Panels Cut panels and discard center piece

(holes are on the left)

(holes are on the right)

Type C (painted) (6)

  • WINDOW REQUIREMENTS
  • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
  • The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.
  • All supporting parts must be secured to firm wood, masonry or metal.
  • The electrical outlet must be within reach of the power cord.

17″ min.

31″ to 43″ (With filler panels)

261⁄4″ min. (Without filler panels)

Window opening dimensions are for

a standard double-hung window.

Show 20 more labels / short text on this page
Vinyl window gasket · Sill support · bracket (2) · hand) · Spring clip (4) · Case top gasket · Bottom window gasket · Right side · Left side · Window locking bracket · Air conditioner · Support bracket hardware · Spacer (2) · Type A (9) · Type D (2) · Lock nut (2) · Type E (4) · Adjusting bolt (2) · Type B (2) · Large washer (2)
Page 17 of the GE AJEQ 08 user manual — E
Page 17 · cliquer pour agrandir
Page 17

STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

WOOD PIECES WIDTH: 2″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame. Attach securely with nails or screws provided by the installer.

1/2″ higher than frame

REMOVE AIR CONDITIONER FROM CASE

F

Remove all shipping pads (if present) inside the air conditioner next to the compressor.

A

Remove the front grille. See the Care and Cleaning section. Find the locking plate located on the front left side.

B

Remove the screw and the locking plate to unlock the air conditioner.

Remove shipping pads (if present)

G

Remove the rear grille that is taped to the back of the case. Remove the packet of screws taped to the back of the grille. While holding the grille at a 45° angle, insert it into the clips at the top of the case and push the bottom in. Keep slight upward pressure on the grille until it fits flush with the bottom of the case.

D

Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case.

If attaching the grille from the outside of the case, use the 2 long screws.

If attaching the grille from the inside of the case, use the 2 short screws.

E

Pull the bottom corners of the air conditioner and slide it out of the case.

Insert the 2 long screws

Insert the 2 short screws

Show 14 more labels / short text on this page
Wood · Stool · Sill · Storm window · frame · Locking · plate · Remove · screw · Clips · Remove · screw · on the outside · on the inside
Page 18 of the GE AJEQ 08 user manual — N OTES:
Page 18 · cliquer pour agrandir
Page 18

WINDOW INSTALLATION—OPTIONAL (cont.)

PREPARE WINDOW

A B

Measure 123⁄8″ from the centerline on both sides for the sill support brackets.

Mark the centerline of the stool. Measure from the centerline 133⁄8″ on both sides for the panel cuts.

133⁄8″

133⁄8″ 123⁄8″ 123⁄8″

INSTALL SILL SUPPORTS

Turn the bolts and tighten the lock nuts to make the sill supports level or tilt down 1/8″ to the outside. Line up the “V” notch with 123⁄8″ marks. Drill pilot holes and attach the sill supports.

A

Assemble the sill supports. Do not fully tighten the spacer mounting screws at this time.

Spacer mounting screws Type (A)

Large washer (for use with wood sills)

Offset sill (such as brick or stone)

B

Before attaching the sill supports, place them on the window stool. Select the spacer position that will place the spacer near the outermost point on the sill. Tighten the spacer mounting screws.

N OTES:

  • On narrow sills, there may not be enough room to use the lock nut.
  • A deep offset sill may require a longer adjusting bolt than the standard hex-head bolt provided.
  • On wood sills use the large washer between the bolt head and the sill. This prevents the bolt from digging into the wood.

Screws are in position

Show 24 more labels / short text on this page
Centerline · Sill · Centerline · Sill · Outside Outside · Inside Inside · Stool · Stool · Type B · Average sill · Type E · Spacer · Sill support · Sill support · Spacer · Narrow sill · Lock nut · Adjusting bolt · Sill support · “V” notch · Inside · Stool · Sill Bolt · Outside
Page 19 of the GE AJEQ 08 user manual — B
Page 19 · cliquer pour agrandir
Page 19

MEASURE, CUT AND INSTALL FILLER PANELS

A

Measure from the edge of the panel marks (see Prepare the Window) to the inside of the window track on each side (A and B).

Type C (painted screws)

133⁄8″ 133⁄8″

A

Width of the air

B

conditioner (panel marks) Left side

D

Install the panels in the window. Place the spring clips 3″ from the top and the bottom. Squeeze and push the clips to fit in the window track and the tab into the sill support.

B

Mark the A and B measurements on each side of the filler panel board. Cut the panels and discard the center piece. Note position of the notches.

B

A

(holes are on the right)

(holes are on the left)

Cut panels and discard center piece

Hook the tab into the sill support

Put together the panel assemblies. Remove the paper backing from the case-side gasket and attach it to the angle. Push a pencil point through the gaskets to locate the holes in the angles.

Show 16 more labels / short text on this page
Gasket · Angle · Angle · Sill · Window track · Outside · Gasket · Panel · Tab · Inside · Right side · 3″ · Right · Left side · side · Filler Panels
Page 20 of the GE AJEQ 08 user manual — D
Page 20 · cliquer pour agrandir
Page 20

WINDOW INSTALLATION—OPTIONAL (cont.)

E

INSTALL CASE IN WINDOW

With the window closed, mark where the window sash meets the case.

A

Peel off the backing from the bottom window gasket.

F

Peel off the backing from the case top gasket.

B

G

Place the gasket on the stool and over the brackets, even with the rear edge, sticky side down.

Hold on to the case, open the window and place the gasket along the mark on the case.

Put the gasket on top of the case where the window will close.

Carefully slide the empty case into the window until the holes in the case line up with the holes in the panel angles.

H

Place the vinyl window gasket over the case top gasket. Insert the panel tabs through the slits in the gasket. Cut the gasket on each side to the width of the window.

N OTES:

  • The case should have a 1/8 ″ minimum tilt toward the outside.
  • Be sure the seal gasket and panel gaskets remain in position and do not roll with the case.

D

Lower the window so it fits behind the panel tabs. Insert the 4 type A screws through the holes in the case and into the panel angles, 2 on each side.

Close the window tightly on the vinyl gasket. Bend the gasket forward to expose the panel tabs. Drill pilot holes into the window sash.

Attach the panel tab to the window on each side with a type D screw.

Show 7 more labels / short text on this page
Bottom window gasket · Case holes · Panel tab · Vinyl window gasket · Panel · tabs · Case screws
Page 21 of the GE AJEQ 08 user manual — Window Installation (Optional)
Page 21 · cliquer pour agrandir
Page 21
GE AJEQ 08 — Window Installation (Optional) diagram (page 21)
Fig. 4 · Window Installation (Optional)

Cut the foam top window gasket to the window width.

Attach the window locking bracket with 1 type E screw.

Stuff the foam between the glass and the window to prevent air and insects from getting into the room.

Reinstall the locking plate with the tab behind the wall case flange. Tighten the screw.

Carefully slide the air conditioner back into the case.

Reattach the front grille. An opening for the power cord is on the bottom of the front grille.

Fill holes and cracks with caulking provided by the installer.

Attach the power cord to the base pan with the clamp.

Page 22 of the GE AJEQ 08 user manual — Normal Operating Sounds
Page 22 · cliquer pour agrandir
Page 22

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

Before you call for service…

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do

Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.

The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.

Power failure. • If power failure occurs, turn the air conditioner OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

  • The current interrupter
  • Press the RESET button located on the power cord plug. device is tripped.
  • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
  • Air conditioner does Airflow is restricted.
  • Make sure there are no curtains, blinds or furniture blocking not cool or heat (some the front of the air conditioner. models) as it should The temp control may
  • In COOL mode or HEAT mode (some models), press the not be set correctly. DECREASE – pad.

The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.

The room may have been hot. • When the air conditioner is first turned on, you need to allow time for the room to cool down.

  • Cold air is escaping.
  • Check for open furnace registers and cold air returns.
  • Make sure the air conditioner’s vent is in the closed position.

Cooling coils have iced up. • See “Air conditioner freezing up” below.

Air conditioner Ice blocks the airflow • Set the controls at HIGH FAN or HIGH COOL and set the freezing up and stops the air conditioner thermostat to a higher temperature to allow the ice to melt. from cooling the room.

The remote control is The batteries are inserted • Check the position of the batteries. They should be not working incorrectly. inserted correctly.

The batteries may be dead. • Replace the batteries.

Water drips outside Hot, humid weather. • This is normal.

Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner tilted to the outside. slants slightly from the case front to the rear.

Water collects in Moisture removed from air • This is normal for a short period in areas with little base pan and drains into base pan. humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

  • You may hear a pinging noise caused by water
  • Water will collect in the base pan during high

being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

  • The fan may run even when the compressor
  • You may hear the thermostat click when the

does not.

compressor cycles on and off.

Page 23 of the GE AJEQ 08 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 23 · cliquer pour agrandir
Page 23

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

Air Conditioner Warranty.

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line visit us at GEAppliances.com, or call 800.GE.CARES (800.432.2737). For service in Canada, contact Gordon Williams Corp. at 1.888.209.0999. Please have serial number and model number availa ble when calling for service.

Staple your receipt here. Proof of the original purchase

date is needed to obtain service under the warranty.

For The Period Of: GE Will Replace:

One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor original purchase and related service to replace the defective part.

Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.

What GE Will Not Cover:

  • Service trips to your home to teach you how to use
  • Replacement of house fuses or resetting of circuit

the product.

breakers.

  • Improper installation, delivery or maintenance. If you
  • Failure due to corrosion on models not corrosion-

have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

protected.

  • Damage to the product caused by improper power

supply voltage, accident, fire, floods or acts of God.

  • Incidental or consequential damage caused by possible
  • Failure of the product resulting from modifications to

defects with this air conditioner.

the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

  • Damage caused after delivery.
  • Product not accessible to provide required service.
  • In commercial locations labor necessary to move the

unit to a location where it is accessible for service by an individual technician.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 24 of the GE AJEQ 08 user manual — Consumer Support
Page 24 · cliquer pour agrandir
Page 24

Consumer Support.

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 5 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 6 · Consumer Support

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 7 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 8 · Consumer Support

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800.626.2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 9 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 10 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225

GE AJEQ 08 — Consumer Support diagram (page 24)
Fig. 11 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.

Printed in China

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : GE AJEQ 08

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le GE AJEQ 08

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

GE AJEQ 08 manuel PDF

72 pages·5.1 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…