FR
GE logo
Notice d'utilisation officielle

GE AE1RD10AM

56 pages·6.1 MB·Climatiseur·PDF·ENDEITNLJA
GE AE1RD10AM
Table des matières 27 sections English · Safety Instructions · Operating Instructions · Batteries · … AfficherMasquer
Page 1 of the GE AE1RD10AM user manual — 49-7600 05-09 JR
Page 1 · cliquer pour agrandir
Page 1

Air Conditioners Mini Split-System

Safety Instructions 2

Owner’s Manual and Installation Instructions

Operating Instructions Batteries 3 Care and Cleaning 6, 7 Remote Control Features 4, 5

Cool Only Models AE1CD10AM / AE0CD10AM AE1CD14DM / AE0CD14DM AE1CD20DM / AE0CD20DM

Installation Instructions Air Purging and Leakage Test 15 Before You Begin 8 Connection Tubing 11 Dimensions 9 Drainage Hose 11 Electrical Requirements 8 Electrical Wiring 12–14 Indoor Unit 12, 13 Location 10 Outdoor Unit 14, 15 Tubing Hole 11 Power Line 14 Mounting Plate 11 Test Operation 16 Wiring Indoor Unit 12 Wiring Outdoor Unit 14

Heat/Cool Models AE1RD10AM / AE0RD10AM AE1RD14DM / AE0RD14DM AE1RD20DM / AE0RD20DM

Climatiseurs

Minibloc

Manuel d’utilisation et instructions d’installation

La section française commence à la page 19

Troubleshooting Tips 17 Normal Operating Sounds 17

Acondicionador de aire

Consumer Support Consumer Support Back Cover Warranty 18

de sistema mini split

Manual del propietario

e instrucciones de

instalación

La sección en español empieza en la página 37

Write the model and serial numbers here for the indoor and outdoor units:

Indoor Model #

Indoor Serial # ____________________

Outdoor Model # ____________________

Outdoor Serial # ____________________

Find these numbers on a label on the side of each unit.

49-7600 05-09 JR

Page 2 of the GE AE1RD10AM user manual — Safety Instructions
Page 2 · cliquer pour agrandir
Page 2
Safety InstructionsIMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS I Use this equipment only for its intended I All electrical work must be completed by a purpose as described in this Owner’s qualified electrician and completed to local Manual. and national building codes and regulations. I This system must be properly installed I Any servicing must be performed by a in accordance with the Installation qualified individual. Instructions before it is used. WARNING! I Risk of fire. Can I All wiring should be rated appropriate for cause injury or death: Do not store or use the current value listed on the rating plate. combustible materials, gasoline or other Use only copper wiring. flammable vapors or liquids in the vicinity WARNING! of this or any other appliance. I Risk of electric shock. Can cause injury or death: Earth For any service which requires entry connection is essential before connecting into the refrigerant sealed system, the power supply. Federal regulations require the work WARNING! be performed by a technician having I Risk of electric a Class II or Universal certification. shock. Can cause injury or death: Disconnect all remote electric power supplies before servicing. I All air conditioners contain refrigerants, which under federal law must be removed WARNING! I Risk of electric prior to product disposal. If you are getting shock. Can cause injury or death: Repair or rid of an old product with refrigerants, check replace immediately all electrical wiring with the company handling disposal. that has become frayed or otherwise I R410A air conditioning systems require damaged. Do not use wiring that shows contractors and technicians to use tools, cracks or abrasion damage along its equipment and safety standards approved length or at either end. for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS 2 Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support
Page 3 of the GE AE1RD10AM user manual — NOTES:
Page 3 · cliquer pour agrandir
Page 3

Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions

Operating the air conditioner. GEAppliances.com

General Procedure

Press the FAN pad to set the desired fan speed (AUTO/Low/Medium/High).

Make sure power is connected and press the ON/OFF pad to start the system.

Press the TEMP +/– pads to set the desired temperature.

Press the MODE pad to select the desired operation mode.

Press the SWING pad for automatic rotation of the louvers. Press again to stop the rotation.

How to Insert Batteries

The remote control uses two AAA batteries.

Remove the cover from the back of the remote control and insert two new batteries (pay attention to the polarity).

Reattach the cover.

NOTES:

I Do not mix new and used batteries or different

types of batteries.

Battery typeAAA

I Remove batteries when the remote control is not

in use for an extended time.

I The remote control signal can only be received

within a range of 20 ft.

I The remote control should be placed about

3 feet or more away from TV sets or any other electrical appliances.

Battery cover

Page 4 of the GE AE1RD10AM user manual — Instructions
Page 4 · cliquer pour agrandir
Page 4

Instructions Safety Instructions Installation

About the remote control.

The remote control transmits the signals to the system.

Features and appearance may vary.

AUTO—In this mode, the unit automatically controls the room temperature within the range of 77ºF and 68ºF. The fan will run continuously while the unit is in AUTO mode. When the room temperature exceeds 77ºF, the unit will go into COOL Mode. When the room temperature drops to 73ºF, the fan will continue to run but COOL Mode will turn off. When the temperature drops below 68ºF, the unit will go into HEAT Mode. When the temperature reaches 73ºF, the fan will continue to run but HEAT Mode turns off. NOTE: This temperature range setting cannot be adjusted and will not be displayed.

Swing on Clock and timer

Consumer Support Troubleshooting Tips Operating

Timer set ON and OFF

COOL—Use to cool the room to the desired temperature set between 61ºF and 86ºF. NOTE: The unit will not provide optimum cooling if the outside temperature is below 60ºF. Under certain conditions, the unit may activate the antifreeze protection cycle for approximately 5 minutes to remove ice from the indoor coil.

Instructions

DRY—Use to dehumidify the room. The fan will run at a fixed low speed to provide maximum dehumidification. The temperature can be set between 61ºF and 86ºF.

FAN—Use to turn ON and OFF the fan-only operation. COOL, HEAT or DRY mode will not be provided.

HEAT (on models so equipped)—Use to warm the room to the desired temperature set between 61ºF and 86ºF. NOTE: The unit will not provide optimum heating if the outside temperature is below 14ºF. Under certain conditions, the unit may activate the antifreeze protection cycle for approximately 8 minutes to remove ice from the outdoor coil. During this cycle, it is normal to hear operating sounds such as refrigerant flowing inside the system.

Show 5 more labels / short text on this page
Fan setting · Operation · Mode · Sleep on · Temperature
Page 5 of the GE AE1RD10AM user manual — Features of the Remote Control
Page 5 · cliquer pour agrandir
Page 5

Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions

About the remote control . (cont.) GEAppliances.com

The remote control transmits the signals to the system.

Features of the Remote Control

Display Displays all set contents when turned on. Displays only the set temperature and time when turned off. ON/OFF Pad Press to turn the system on and off. MODE Pad Press to change the operation mode to AUTO, (COOL), (DRY), (FAN ONLY) or (HEAT). TEMP Pads Press + to increase the set temperature in 1ºF increments. Press – to decrease the set temperature in 1ºF increments. In the COOL and HEAT modes, the set temperature can be selected from 61ºF to 86ºF. The set temperature will not be displayed in the AUTO mode. FAN Pad Press to change the fan speed to AUTO FAN, (Low Fan), (Medium Fan) or

T-ON (Timer ON) Pad When the air conditioner is off, press T-ON (timer on) to set it to turn on automatically (using its previous settings) at the time you set.

Press TIME- or TIME+ pads to set the start time in 1-minute increments.

Press and hold the TIME- or TIME+ pads to set the start time in 10-minute increments.

To cancel ON (T-ON), press the CANCEL pad.

T-OFF (Timer OFF) Pad When the air conditioner is on, press T-OFF (timer off) to set it to automatically turn off at the time you set.

Press TIME- or TIME+ pads to set the turn- off time in 1-minute increments.

Press and hold the TIME- or TIME+ pads to set the turn-off time in 10-minute increments.

(High Fan). SWING Pad Press for automatic rotation of the louvers. Press again to stop them from rotating. SLEEP Pad Press to turn the sleep mode on and off. When in the cooling mode and the sleep timer is set, the set temperature will automatically increase 2ºF after the first hour and 2°F after the second hour. SLEEP Mode is compatible with COOL, HEAT and DRY. CLOCK Pad Press to set the time of day. Press TIME- or TIME+ pads to set the time in 1-minute increments. Press and hold the TIME- or TIME+ pads to set the time in 10-minute increments.

To cancel OFF (T-OFF), press the CANCEL pad.

TIME Pads Use when setting the CLOCK and timers (T-ON and T-OFF). Press to set in 1-minute increments. Press and hold to set in 10-minute increments.

CANCEL Pad Press to cancel the timer(s).

Page 6 of the GE AE1RD10AM user manual — Instructions
Page 6 · cliquer pour agrandir
Page 6

Instructions Safety Instructions Installation

Care and cleaning of the air conditioner.

Indoor Unit

Grille, Case and Remote Control

Air Filters The two air filters behind the front grille should be checked and cleaned at least every 30 days or more often, if necessary.

Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

Consumer Support Troubleshooting Tips Operating

Open the front access panel.

Instructions

Pull the filter tab slightly forward to remove the filter. Clean the filter with a vacuum or warm, soapy water. Rinse and allow the filter to dry before replacing it.

Reinsert the filters and close the front access panel.

Air intake vent · Air outlet vent

Page 7 of the GE AE1RD10AM user manual — Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions
Page 7 · cliquer pour agrandir
Page 7
GE AE1RD10AM — Care and Cleaning diagram (page 7)
Fig. 1 · Care and Cleaning

Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or debris, the heat exchanger and panel vents should be professionally cleaned.

I Dirty or clogged coils will reduce the operating

efficiency of the system and cause higher operating costs.

Operate the system in the fan mode for 2 hours. This will dry out the system.

Page 8 of the GE AE1RD10AM user manual — BEFORE YOU BEGIN
Page 8 · cliquer pour agrandir
Page 8

Mini Split-System Air Conditioners

BEFORE YOU BEGIN

ELECTRICAL REQUIREMENTS

Read these instructions completely and carefully.

  • Be certain all wiring complies with local building codes and NEC and that the supply voltage for this system is correct. The system supply voltage is connected to the outdoor unit only.
  • IMPORTANT — Save these instructions for local inspector’s use.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – A licensed, certified (to handle refrigerantR410A, recovery, etc.) technician and a qualified electrician are required for installation of this split air conditioning system.
  • Completion time – Approximately 2 1 ⁄ 2 hours
  • Two people are required to install this unit due to the weight of the product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • For personal safety, this system must be properly grounded.
  • Protective devices (fuses or circuit breakers) acceptable for installation are specified on the nameplate of each unit.
  • Servicing and installation of the refrigerant system must be performed only by a licensed, HVAC-certified technician.
  • Make sure to avoid wiring or plumbing inside the wall when installing.
  • For any service which requires entry into the refrigerant sealed system, Federal regulations require the work be performed by a technician having a Class II or Universal certification.
  • Check the rating nameplate on the side panel of outdoor unit for required circuit protection rating and required supply voltage.
  • Use UL-approved electrical branch circuit disconnect for providing supply voltage to split system indoor and outdoor units. Locate disconnect within sight and readily accessible per NEC and local codes.
  • All wiring should be rated appropriate for the current value listed on the rating plate.
  • Be certain there is an uninterrupted, unbroken electrical ground connection.
  • Wiring should be encased in liquid-tight tubing with connections sealed with liquid-tight connectors.
  • CAUTION:
  • Do not use an extension cord with this system.
  • Aluminum building wiring may present special problems—consult a qualified electrician.
  • When the unit is in the STOP position, there is still voltage to the electrical controls.
  • Disconnect the power to the system before servicing by removing the branch circuit fuses or turning the circuit breakers off at the panel.
  • DO NOT use equipment certified for R22 refrigerant only.
Page 9 of the GE AE1RD10AM user manual — OPTIONAL ACCESSORY KITS
Page 9 · cliquer pour agrandir
Page 9

PARTS INCLUDED INSTALLATION DIMENSIONS

  • Mounting plate
  • Sealer
  • Screws (5 for 10,000 and 14,000 BTU models/10 for 20,000 BTU models)
  • Remote control
  • Batteries AAA (2)
  • Drainage hose
  • Insulation hose
  • Two (2) filters

6” or more space to the ceiling

SUPPLIED BY INSTALLER

6” or more space to the wall

6” or more space to the wall

Adapter1/4 ″ male flare with Schrader

valve x 5/16″ female (1/2″-20UN)

Wr apapping e 12” mo intor re air ake side 20” or more space to the wall

OPTIONAL ACCESSORY KITS

118” or more air outlet side

79” or more space to the floor

To aid installation, the following tubing kits may be ordered:

GE KitTUE1650 TUE3250 For use on modelsAE1CD10AM AE0CD10AM AE1RD10AM AE0RD10AM AE1CD14DM AE0CD14DM AE1RD14DM AE0RD14DM Suction line dia. and length1/2″ x 16 ft.1/2″ x 32 ft. Liquid line dia. and length1/4″ x 16 ft.1/4″ x 32 ft. Tube insulation length16 ft.32 ft. Wall hole sleeves (2)includedincluded PVC wrapping tapeincludedincluded

12” or more space to the wall

79” or more air outlet side

111⁄4”–10K and 14K BTU models 117⁄8”–20K BTU models

211⁄4”–10K and 14K BTU models 227⁄16”–20K BTU models

  • IMPORTANT NOTES:
  • The installation must be done by a trained and qualified electrician and technician with Class II or Universal certification.
  • When picking up and moving the units, you must be guided by trained and qualified personnel .
GE KitTUE1662 TUE3262 For use on modelsAE1CD20DM AE0CD20DM AE1RD20DM AE0RD20DM Suction line dia. and length5/8″ x 16 ft.5/8″ x 32 ft. Liquid line dia. and length3/8″ x 16 ft.3/8″ x 32 ft. Tube insulation length16 ft.32 ft. Wall hole sleeves (2)includedincluded PVC wrapping tapeincludedincluded
Page 10 of the GE AE1RD10AM user manual — A
Page 10 · cliquer pour agrandir
Page 10

Read these instructions completely and carefully; then follow step by step.

SELECT THE BEST LOCATION 1

  • B INDOOR UNIT
  • Do not allow any heat or steam near the unit.
  • Select a location where there are no obstacles in front of the unit.
  • Make sure that condensate drainage can be conveniently routed away.
  • Do not install near a doorway.
  • Ensure that the space around the left and right of the unit is more than 6 ″ . The unit should be installed as high on the wall as possible, allowing a minimum of 6 ″ from ceiling.
  • Use a stud finder to locate studs for mounting and to prevent unnecessary damage to the wall.
  • Install on studs and in a location from which the condensation water can be drained out conveniently and that permits easy connection with the outdoor unit.
  • Do not cover the inlet and outlet so that the outflow air can reach all parts of the room.
  • Install in a location that is strong enough to withstand the full weight and vibration of the unit.
  • Be sure that the installation conforms to the installation dimension diagram.
  • Leave enough space to allow access for routine maintenance. The height of the installed location should be 79 ″ or more away from the floor.
  • Install in a location that is 3 ft. or more away from other electrical appliances, such as televisions and audio devices.
  • Select a location that gives you easy access to remove and clean the filter.

A

  • OUTDOOR UNIT
  • If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
  • Ensure that the space around the back and sides is more than 12 ″ . The front of the unit should have more than 79 ″ of space.

The platform must support a minimum of 200 lbs. See Installation Dimensions for mounting hole spacing.

  • Install in a location that is strong enough to permit safe installation and to withstand the full weight and vibration of the unit.
  • Construct and anchor a strong and level mounting base or pad for the outdoor unit.
  • Anchor the outdoor unit through its four mounts, using bolts.
  • Select a location from which noise and outflow air emitted by the unit will not inconvenience neighbors.
  • In humid locations, the unit may sweat and condensation (water) may drip from it. Take this into consideration when choosing the location.
  • Select a location that has sufficient ventilation.
  • Do not cover the inlet and outlet.
  • Install unit away from flammable gas or corrosive gas leaks.
  • Be sure the installation conforms to the installation dimension diagram.
  • Rooftop Installations: If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.
Show 7 more labels / short text on this page
More than 12” · More than 12” · More than 79” · More than 6” · More than 6” · More than 6” · More than 79”
Page 11 of the GE AE1RD10AM user manual — INSTALLATION 2
Page 11 · cliquer pour agrandir
Page 11

INSTALLATION 2

  • INSTALL THE MOUNTING PLATE
  • Always mount the mounting plate horizontally.
  • Attach the mounting plate at the selected location with screws supplied with the unit.
  • Be sure that the mounting plate has been attached firmly enough to withstand the weight of an adult of 130 lbs. Also, the weight should be evenly shared by each screw.

INSTALL THE CONNECTION TUBING • Connect the copper tubing with the relevant union tubes of the indoor unit and tighten the flare nut of the connection tubes. NOTE: Be careful when bending the connection tubes to avoid damaging them. 1. Align the center of the tube flare with the relevant valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench. See the table below for the correct torque. 3. Connecting tube specifications are shown below:

INSTALL THE TUBING HOLE • Make the tubing hole in the wall at a slight downward slant to the outdoor side.

Specifications10,000/14,000 BTU Units20,000 BTU Units Design Length Extra Refrigerant Charge Per Ft. Above Design Length20 ft. 0.16 oz./ft.26.2 ft. 0.54 oz./ft. Outer Diameter Liquid Pipe1/4″3/8″ Outer Diameter Gas Pipe1/2″5/8″ Max. Distance Height33 ft.33 ft. Max. Distance Length68 ft.98 ft.

3” from right edge to center of right tubing hole

Hole is 2” diameter for 10K and 14K BTU

11⁄2” from bottom edge to center of right tubing hole

models and 21⁄2” diameter for

20K BTU models.

  • To let water drain and prevent damage to wiring and tubing, insert a 2 1 ⁄ 2 ″ plastic pipe, cut to a length equal to the wall depth. Insert the tubing and wiring through the pipe.
  • Copper tubing should be capped until ready to install flare fitting, to prevent contamination.
Tubing ODTightening torque (in./lb.) 1/4″140–170 3/8″270–310 1/2″440–480 5/8″530–570
  • INSTALL THE DRAINAGE HOSE
  • For good drainage, the drain hose should be placed at a downward slant.
  • Do not wrench or bend the drain hose or allow it to contact standing water.
  • The extended drainage tube in the room should be wrapped with the insulating materials.
Show 7 more labels / short text on this page
Tightening torque table · Spanner · Bend Wrenched · Flare nut · Joint · Flooded · Torque wrench
Page 12 of the GE AE1RD10AM user manual — INSTALLATION (cont.) 2
Page 12 · cliquer pour agrandir
Page 12

INSTALLATION (cont.) 2

  • CONNECT ELECTRICAL WIRING BETWEEN INDOOR AND OUTDOOR UNITS
  • All wiring should be rated appropriately for the current value listed on the rating plate.
  • The power supply should accommodate the rated voltage.
  • Wiring must be done by a qualified electrician according to local codes, regulations and this manual.
  • All wiring connections should be tightened securely.

WIRE THE INDOOR UNIT (cont.) NOTE: Wiring must be done by a qualified electrician according to the local codes and regulations and this manual. The connecting wire should be correctly connected to the circuit interface.

WIRE THE INDOOR UNIT NOTE: Use UL-approved electrical branch circuit disconnect for providing supply voltage to split system indoor and outdoor units. Locate disconnect within sight and readily accessible per NEC and local codes. 1. Open the front access panel. 2. Remove the cover plate of the electrical box.

Electrical wires must be secured with attached strain reliefs.

*L1 will be used for neutral in 115V models.

Indoor unit Outdoor unit

3. On the back of the indoor unit, remove the conduit connecting cover. Using the fixing nut, connect the conduit to the connecting cover. Route the wire leads through the unit to the electrical box area. Reinstall the connecting cover.
  • NOTES:
  • Wiring should be consistent with the wiring diagrams above.
  • Tighten the nut of the terminal board to keep the board secured.
  • After tightening, the wire cannot be removed if pulled.
  • Incorrect wiring will cause the air conditioner to work abnormally.
  • Incorrect grounding will cause a short circuit. 4. Replace the cover plate over the electrical box and lower the access panel into position.
Show 18 more labels / short text on this page
4-way terminal board · Power connection cord · 115V Models · Outdoor unit · Indoor unit · Power supply · To branch circuit · Access panel · Ground · Cover plate · 230/208V Models · Power supply · To branch circuit · Ground · Back of unit · Fixing nut · Connecting cover · Conduit
Page 13 of the GE AE1RD10AM user manual — INSTALLATION (cont.) 2
Page 13 · cliquer pour agrandir
Page 13

INSTALLATION (cont.) 2

INSTALL THE INDOOR UNIT • Route the tubes and wiring from the right side of the indoor unit. Cut off the tailings from the chassis as necessary.

7 INSTALL THE INDOOR UNIT (cont.) • Wrap the tubes and wiring and pull them through the cut-off-tailings hole.

1. Cut off tailings 1 when routing the wiring only. 2. Cut off tailings 1 and 2 (or tailings 1, 2 and 3) when routing both the wiring and tubing. 1 and 2 below are the recommended tubing.

Control cord (for cooling/heating type only)

  • Hang the mounting slots of the indoor unit on the upper tabs of the mounting plate and make sure it is firm enough.

2 Right rear tube

  • The height of the installed location should be 79 ″ or more from the floor.
Show 8 more labels / short text on this page
Wrapping tape · Connection tubes · Power connection cord · Drainage hose · 1 Right tube · Tailings 3 · Tailings 2 · Tailings 1
Page 14 of the GE AE1RD10AM user manual — INSTALLATION (cont.) 2
Page 14 · cliquer pour agrandir
Page 14

INSTALLATION (cont.) 2

WIRE THE OUTDOOR UNIT 1. Open the cover of the outdoor unit. 2. The connecting wire lead from the terminal board of the indoor unit must be connected correctly. 3. The connecting wire should be a little longer so that it can be maintained easily.

  • 8 WIRE THE OUTDOOR UNIT (cont.) NOTES:
  • Wiring should be consistent with the above wiring diagrams.
  • Wiring must be correct.
  • Tighten the nut of the terminal board to keep the board secured.
  • After tightening, the wire cannot be removed if pulled.
  • Incorrect wiring will cause the air conditioner to work abnormally.
  • Incorrect grounding will cause a short circuit.
  • Electrical connections must be made by a qualified electrician.
  • All electrical work must be completed according to local codes and regulations.

INSTALL THE POWER LINE 1. Open the wiring cover and remove the knockouts. 2. The connector should be secured by the nut, and the wiring cover should be replaced and secured with the included screw. 3. All wiring should be protected by liquid-tight tubing, and connections to the wiring cover should be with liquid-tight connectors.

Wrap electrical cords with attached metal tie to provide strain relief.

10,000 and 14,000 BTU Models

*L1 will be used for neutral in 115V models.

Indoor unit Outdoor unit

  • NOTES:
  • The connecting wire and connection tube cannot touch each other.
  • The top cover of the outdoor unit and the electrical box assembly should be fixed by the screw. Otherwise, it can cause a fire or a short circuit caused by water or dust.
  • Use a UL-approved electrical branch circuit disconnect for providing supply voltage to the split system outdoor unit. Locate the disconnect within sight and readily accessible per NEC and local codes.
Show 14 more labels / short text on this page
6-way terminal board · 115V Models · Outdoor unit · Indoor unit · Power supply · Connector · To branch circuit · Ground · Electrical box assembly · 230/208V Models · Wiring cover · Power supply · To branch circuit · Ground
Page 15 of the GE AE1RD10AM user manual — INSTALLATION (cont.) 2
Page 15 · cliquer pour agrandir
Page 15

INSTALLATION (cont.) 2

INSTALL THE OUTDOOR UNIT • Install the connection tube 1. Align the center of the tubing flare with the relevant valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench. See the table below for the correct torque. 3. Connecting tube specifications are shown below:

10 PURGE THE AIR AND TEST FOR LEAKAGE 1. Install the connecting tubes of the indoor/outdoor unit. 2. DO NOT OPEN THE GAS VALVES UNTIL THE EVACUATION PROCESS IS COMPLETE. 3. Remove the gas line service port cap and connect the gas valves of the vacuum gauge, vacuum pump and outdoor unit. NOTE: Connect by using a 1/4″ Female x 1/2″ Male Adapter Access Fitting (obtain locally). 4. Start the vacuum pump. (Running time should be more than 15 minutes.) 5. Check the vacuum with the vacuum gauge. The gauge should read -30 in. Hg. After evacuation, fully close the handle on the manifold valve (on the vacuum pump device). Then stop the vacuum pump and disconnect it. 6. The pressure should be kept for 1–2 minutes to confirm that the reading of the vacuum gauge does not change. The pressure should be -30 in. Hg. 7. Remove the vacuum line and replace the service port cap. 8. Remove both the liquid and gas valve caps. 9. Open the gas and liquid valve entirely, using the 5 mm Allen wrench. If this is not done, the performance will be reduced, or an error will occur. 10. Replace the caps and tighten securely.

10,000/14,000 20,000 Specifications BTU Units BTU Units

Design Length 20 ft. 26.2 ft.

Extra Refrigerant Charge 0.16 oz./ft. 0.54 oz./ft. Per Ft. Above Design Length

Outer Diameter Liquid Pipe 1/4″ 3/8″

Outer Diameter Gas Pipe 1/2″ 5/8″

Max. Distance Height 33 ft. 33 ft.

Max. Distance Length 68 ft. 98 ft.

Tubing OD Tightening torque (in./lb.)

Show 14 more labels / short text on this page
Tightening torque table · 1/4″ 140–170 · 3/8″ 270–310 · 1/2″ 440–480 · 5/8″ 530–570 · Vacuum gauge · Spanner · Cap · Flare nut · Joint · Torque wrench · Liquid tube · Vacuum pump · Gas tube
Page 16 of the GE AE1RD10AM user manual — Installation Checklist
Page 16 · cliquer pour agrandir
Page 16

TEST OPERATION AND CHECK AFTER INSTALLATION Test operation

  • 1. Before test operation
  • Do not switch on power before installation is finished completely.
  • Electrical wiring must be connected correctly and securely.
  • Shut-off valves of the connection tubes should be opened.
  • All impurities such as scraps and particulates must be cleared from the unit.
  • 2. Test operation method
  • Switch on power and press the ON/OFF pad on the remote control to turn on the air conditioner.
  • Press the MODE pad and check the operation conditions of each of the modes.

10,000 and 14,000 BTU models only: • If the remote control is lost, the emergency run operation can be performed with a ballpoint pen or similar object. a. When the unit is off, set the handling switch to the AUTO mode.

10,000 and 14,000 BTU Models

The unit will then automatically run in the mode selected by the microcomputer system according to the surrounding temperature. If you want to turn the unit off, press the handling switch again. b. When the unit is on, set the handling switch to the STOP mode to

turn off the unit.

20,000 BTU models only: • If the remote control is lost, open the front access panel and perform the following: a. Set the handling switch to the AUTO position to operate in the

AUTO mode. Once there is a remote control signal, the unit will again be controlled by that signal. b. Set the handling switch to the STOP position to turn off the unit.

Installation Checklist

K Has the unit been securely installed? If not, the unit may fall, shake or make noises. K Has the refrigerant leak test been performed? Leakage may cause insufficient cooling capacity. K Does the unit drain well? Poor drainage can cause condensation and dripping. K Is the voltage correct according to the nameplate? Incorrect voltage may cause electrical malfunction. Diagnostic

information is available for this unit. Contact your service technician. K Is the unit properly grounded? A nonsecure ground connection can cause damage. K Are the air inlet and outlet completely free of cover? Covering the air inlet or outlet may cause insufficient cooling

capacity. K Have the length of the connection tubing and refrigerant capacity been recorded? It is important to know these

things for future reference.

Handling switch · 20,000 BTU Models · Handling switch

Page 17 of the GE AE1RD10AM user manual — Normal Operating Sounds
Page 17 · cliquer pour agrandir
Page 17

Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions

Before you call for service… GEAppliances.com

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do

The system The fuse is blown/circuit •Check the house fuse/circuit breaker box and does not start breaker is tripped. replace the fuse or reset the breaker.

The Timer operation is not set •Check the Timer functions and make sure they are correctly. set to the desired settings.

The unit does not operate when •This is normal. Wait about 3 minutes and the unit restarted. will restart.

The system does not Airflow is restricted. •Make sure there are no curtains, blinds or furniture cool as it should blocking the front of the system.

The temperature control may •Turn to a lower or higher setting. The lowest setting not be set high or low enough. provides maximum cooling.

The air filter is dirty. •Clean the filter at least every 30 days. See the Operating Instructions section.

The room may have been hot. •When the system is first turned on, you need to allow time for the room to cool down.

Cold air is escaping. •Check for open furnace floor registers and cold air returns.

  • The remote control The batteries are inserted
  • Check the position of the batteries. They should be display is faint or incorrectly. inserted in the opposite (+) and (–) direction. shows no display The batteries may be dead.
  • Replace the batteries . at all

Normal Operating Sounds

I These sounds are common during the

I A noise that sounds like air being released is a

antifreeze cooling or heating modes.

design feature of dehumidifying water being processed inside the system.

I You may hear a sound like water flowing. This

is the sound of refrigerant flowing inside the system.

I You may hear a clicking noise when you start

or stop the unit. This sound is the expansion or contraction of the unit due to changes in the temperature.

Page 18 of the GE AE1RD10AM user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 18 · cliquer pour agrandir
Page 18

Instructions Safety Instructions Installation

Split System Warranty.

All warranty service provided by our designated service network. To schedule service, call 866.404.5245. For service in Canada, contact Gordon Williams Corp. at 1.888.209.0999. Please have serial number and model number availa ble when calling for service.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: GE Will Replace:

One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor original purchase and related service to replace the defective part.

Consumer Support Troubleshooting Tips Operating

Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.

What GE Will Not Cover:

IService trips to your home to teach you how to use

IReplacement of house fuses or resetting of circuit

the product.

breakers.

IImproper installation, delivery or maintenance. If you

IFailure due to corrosion on models not corrosion-

have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

protected.

Instructions

IDamage to the product caused by improper power

supply voltage, accident, fire, floods or acts of God.

IIncidental or consequential damage caused by possible

IFailure of the product resulting from modifications to

defects with this air conditioner.

the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

IDamage caused after delivery.

IProduct not accessible to provide required service.

IIn commercial locations labor necessary to move the

unit to a location where it is accessible for service by an individual technician.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Poser une question sur : GE AE1RD10AM

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le GE AE1RD10AM

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

GE AE1RD10AM manuel PDF

56 pages·6.1 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…