Air Conditioners
Zoneline ®
Safety Instructions 2
Operating Instructions Air Direction 4 Auxiliary Controls 5–8 Controls 3 To Remove the Room Cabinet 4 Ventilation Control 4
Heat/Cool Model 4100 Heat Pump Model 6100
Care and Cleaning Air Filters 10 Base Pan 9 Outdoor Coils 9 Room Cabinet and Case 9 Ventilation Filter 9
For a Spanish version of this manual, visit our Website at www.zoneline.com/literature
Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet www.zoneline.com/literature Français
Installation Instructions Electrical Connection 13–16 Installing the Zoneline 17, 18 Optional Drain Kit 19 Preparation 11 Replacing an Existing Unit? 12
For a French version of this manual, visit our Website at www.zoneline.com/literature
Pour un version français de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse www.zoneline.com/literature
Troubleshooting Tips 20, 21 Normal Operating Sounds 22
Consumer Support Consumer Support Back Cover Warranty 23
Write the model and serial numbers here:
Find these numbers on a label behind the room cabinet on the base pan.
Model # · Serial #

I This Zoneline must be properly installed
I These R410A air conditioning systems
in accordance with the Installation Instructions before it is used. See the Installation Instructions in the back of this manual.
require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. DO NOT use equipment certified for R22 refrigerant only.
I Replace immediately all electric service
cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
For details, see the Installation Instructions in this manual.
I Unplug or disconnect the Zoneline
at the fuse box or circuit breaker before making any repairs.

TEMP CONTROL FAN, MODE & SLEEP OPERATION
Controls
Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. Press the pad to raise the temperature. Press the pad to lower the temperature. NOTE: The display shows the set temperature, not the room temperature. Sleep Press to set the air conditioner to run for 8 hours before it automatically returns to the previous setting. When in the cooling mode and the sleep timer is set, the set temperature will automatically increase 2°F after the second hour then 1°F each hour over the next two hours. Also, the fan speed will change to low. When in the heating mode, the set temperature will decrease in the same manner.
FAN—Sets the fan operation for HIGH, LOW or AUTO speed. When set at AUTO, it automatically switches between LOW and HIGH as room temperature changes.
FAN—For fan-only operation HEAT—For heating
OPERATION—ON/STOP—Turns the unit on or off. Power remains connected to the Zoneline. The Freeze/Heat Sentinel features still function if active.See the Freezer/Heat Sentinel section on page 6.
Quick Heat Recovery Activates each time the thermostat is switched from STOP or COOL mode to HEAT mode. Electric heaters are energized until the thermostat set point is reached. On heat pump models, the heat pump operation will resume at the next call for heat.
To cancel the sleep mode, press the MODE pad or the SLEEP pad a second time.
Heat pumps can save money by removing heat from the outside air—even when the outside temperature is below freezing—and releasing that heat indoors. To get the best performance from your heat pump, don’t change the room thermostat very often. Raising the heat setting 2–3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly.
There is a 3-minute minimum compressor run time at any setting to prevent short cycling. The indoor fan motor starts before the compressor and stops after the compressor cycles off. When the outdoor temperature is lower than 25°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump. The electric heating elements use much more electricity than heat pumps and cost more to operate.
+ – · MODE—COOL—For cooling

Other features of your Zoneline.
Ventilation Control
The ventilation control lever is located at the middle left side of the Zoneline unit, behind the room cabinet.
When set at the closed position, only the air inside the room is circulated and filtered.
When set at the open position, some outdoor air will be drawn into the room. This will reduce the heating or cooling efficiency.
Vent control (shown in middle position)
Remove two shipping screws (if operation is desired)
Energy Tip: Keep the vent control in the closed position. The room air will be filtered and circulated.
Additional controls are located behind the room cabinet.
To remove: Pull out at the bottom to release it from the tabs (1). Then lift up (2).
To replace: Place the tabs over the top rail (1). Push inward at the bottom until it snaps into place (2).
To change the air direction, remove the room cabinet. Remove the 7 louver screws that hold the louver insert in place. Flip the louver insert 180°, replace the screws and the room cabinet.
Remove the room cabinet and flip the louver
insert to change the air direction.

Auxiliary Controls—Aux Set Button
The auxiliary set controls are located behind the room cabinet, below the control panel.
Remove the room cabinet. See the To Remove the Room Cabinet section.
The owner is responsible for ensuring the auxiliary controls are set to the desired function. There are 9 different modes that can be set using the auxiliary set button. To change modes, press AUX SET (“AU” appears on the display). Press the mode button on the control pad until the first digit in the display shows the number corresponding to the mode you are choosing and the correct HEAT/COOL LED is lit. Press the up or down arrow (shown in the second digit of the display) to make the mode setting selection where applicable. Press the AUX SET button to confirm the selection.
Smart Fan—Cooling/Heating
The default setting for Mode 1 is as follows: Cooling: Continuous (ON) Heating: Cycle (OFF)
Press MODE until a 1 appears in the first digit of the display for Smart Fan cool mode. The COOL LED light on the main control will be on. To change to heat mode, press MODE again. The HEAT LEDlight on the main control will be lit. Press the down arrow to set the indoor fan to cycle on/off when the unit is heating or cooling " ." Press the up arrow to set the indoor fan to run continuously " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions.
HIGH COOL LOW FAN AUTO HEAT
HIGH COOL LOW FAN AUTO HEAT
MODE 2
Load Shedding (Central Desk Control)
The default setting for Mode 2 is OFF.
This feature is active only if the unit is connected to a CDC and the CDC has control. Press MODE until a 2 appears in the first digit of the display for Load Shedding mode. Press the down arrow for OFF " " or the up arrow for ON " ." This is shown in the second digit of the display. When this mode is on, only the indoor fan can be turned ON or OFF with the unit controls. When this mode is off, all operation is disabled except Heat/Freeze Sentinel (Mode 3). Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions.
ON

Auxiliary controls on your Zoneline.
MODE 3
Freeze Sentinel/Heat Sentinel
In the default setting for Mode 3, Heat Sentinel is off, Freeze Sentinel is on. Press MODE until a 3 appears in the first digit of the display for Freeze Sentinel mode. The COOL LEDlight on the main control will be on. Press MODE again to change to the Heat Sentinel. The HEAT LEDlight on the main control will be on. Press the down arrow for OFF " " or the up arrow for ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions. When Freeze Sentinel is activated, it automatically provides heat without user interface. This helps to prevent plumbing damage by turning the heater and indoor fan ON at 41ºF and OFF at 46ºF. When Heat Sentinel is activated, it automatically provides cooling without user interface. This helps to prevent an excessively hot room by turning the air conditioner ON at 85ºF and OFF at 80ºF. NOTE: These functions are active whenever the unit is plugged in, even if the unit is in the STOP position.
HIGH COOL LOW FAN AUTO HEAT
HIGH COOL LOW FAN AUTO HEAT
HIGH COOL LOW FAN AUTO HEAT
MODE 4
Constant ON Fan
The default setting for Mode 4 is OFF. Press MODE until a 4 appears in the first digit of the display to set the fan to run continuously at high speed, even if the unit is in the STOP position. Press the down arrow for OFF " " or the up arrow for ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions.
Temperature Limiting
Temperature Limiting Cool – Limit 2
Temperature Limiting Heat – Limit 3
Remote Thermostat – Class 2
The default setting for Mode 6 is OFF. Setting this mode to ON will allow the unit to operate with a Class 2 Remote Control Wall Thermostat. Press MODE until a 6 appears in the first digit of the display for Class 2 mode. Press the down arrow to turn the option OFF " ." Press the up arrow to turn this option ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions.
Class 2 OFF Class 2 ON

MODE 7
Duct Mode
The default setting for Mode 7 is OFF. This setting is used when the unit is installed using a duct adapter kit. If the unit is ducted, the Duct Mode needs to be set to ON. This increases the fan speed to ensure proper circulation. Press MODE until a 7 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode.
For Model AZ6100, press MODE to continue setting other functions. Pressing MODE on Model AZ4100 will return you to AUX SET mode and an “AU” will appear in the display.
Duct Mode OFF Duct Mode ON
All-Electric Heat (AZ6100 only)
The default setting for Mode 8 is OFF. This electric heat option functions only on the 6100 model. When this option is ON " ," heat pump operation is locked out, causing the unit to provide only electric resistance heat. To set All-Electric Heat option, press MODE until an 8 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display.
Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions.
MODE 9
The default setting for Mode 9 is OFF. When Heat Boost is ON and outer temperatures are between 25ºF and 46ºF, heat pump only operation is locked out. This setting is used to provide supplementary heat to the heat pump operation by electric resistance heat in conditions where the heat pump-only operation is not sufficient to maintain a consistent, comfortable room temperature. NOTE: Temperature Boost option should not be used with remote thermostat operation. This will cause the unit to switch to resistance heat when the outdoor temperature is 46ºF.
To set Heat Boost, press MODE until a 9 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode.
Heat Boost OFF Heat Boost ON
The auxiliary controls are located behind the room cabinet beneath the access cover.
The owner is responsible for making all connections and setting the appropriate AUX SET mode.
Turn off and unplug the unit.
Remove the room cabinet. See the To Remove the Room Cabinet section. Remove the screw from the access cover.
To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely. After all desired connections have been made, replace the access cover and room cabinet.
FAN
CDC
24 VAC R
FAN LO G
FAN HI G
REV VAL B
COMP Y
AUX HEAT W
COMMON C
Common White - Heater Yellow - Compressor Black - Solenoid (AZ61 only) Green - High Speed Fan Green - Low Speed Fan Red - 24 V AC only
External Fan Central Desk Control

Auxiliary controls on your Zoneline.
External Fan (Obtained locally)
When connected, an auxiliary or external fan can be controlled with the indoor fan motor on the Zoneline. Connections provide 24 V AC to energize a remote relay, turning on the external fan.
When connected, the unit can be turned ONor OFF with a switch located at the Central Control Panel. A separate wire pair must be run from each separate controlling switch to each individual Zoneline.
Refer to MODE2 on page 5 for fan setting options.
When connected to a remote thermostat, the indoor air temperature sensing is shifted from the unit to the remote thermostat. For this reason, the units will operate slightly differently when connected to a remote thermostat. The following chart shows the unit operation when connected to a remote thermostat.
Class 2 Shown ON
If using a digital/electronic wall thermostat, you must set it to the 24 V ACsetting. See the Installation Instructions for the wall thermostat.

Care and cleaning.
Room Cabinet and Case
Check it periodically and clean, if necessary.
If the vent door is open, access requires the removal of the unit from the wall sleeve. Clean the vent filter twice a year or as required.
To clean the vent filter: IMPORTANT: This filter is not removable. Trying to remove this filter will damage the unit.
Turn the Zoneline off and unplug before cleaning.
I Use a vacuum to remove debris from the filter.
I Use a damp rag to wipe down the filter and
surrounding area after vacuuming.
Remove two shipping screws (if operation is desired)

Care and cleaning.
To maintain optimum performance, clean the filters at least every 30 days.
To remove the air filters:
Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.
Turn the Zoneline off before cleaning.
The most important thing you can do to maintain the Zoneline is to clean the filter at least every 30 days. Clogged filters reduce cooling, heating and air flow.
To replace the air filters:
Keeping these filters clean will:
I Decrease cost of operation.
I Save energy.
I Prevent clogged heat exchanger coils.
I Reduce the risk of premature component failure.
To clean the air filters:
I Vacuum off the heavy soil.
I Run water through the filters from the
back side.
I Dry thoroughly before replacing.
Operating without the filters in place or with damaged filters will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit.
Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.
2 Air filters · Pull up · Push down


BEFORE YOU BEGIN
IMPORTANT ELECTRICAL SAFETY—READ CAREFULLY
Read these instructions completely and carefully.
ZONELINE COMPONENTS Appearance may vary.
** Shipped with the Zoneline unit ** Check the “Essential Elements” list on the unit located on front of the base pan

Replacing a ducted unit New ducted installation: If this unit is to be installed in a new ducted application using a duct adapter kit, the kit must be installed before the unit is placed in the wall case. The installation instructions are packed with the kit.
Check the “Essential Elements” label for important information.
Use the correct wall case This unit is designed to be installed in a GE plastic or insulated metal wall case. This minimizes condensation from forming on the room side of the case. If the current wall case is not insulated, you can reduce the possibility of condensation forming by installing insulation kit RAK901L, available where you purchased the unit. NOTE: There are several extra holes in the unit side flanges for installation in wall cases other than GE. To avoid damaging the flange insulation, the installer should use an awl or other sharp tool to puncture the insulation in the appropriate holes before installing the attachment screws.
Existing ducted installation: Replacement of an existing ducted unit may require different components. Request this information from your sales representative.
Duct Mode Shown ON
Use the correct power cord Local codes may require the use of arc fault or leakage current detection devices on 230/208-volt installations.
Mounting · plate Duct · Case

Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the Zoneline and contact a qualified service technician.
ELECTRICAL SUBBASE CONNECTION
A power supply kit with LCDI must be used to supply power to the Zoneline unit. The appropriate kit is determined by the voltage, the means of electrical connection and the amperage of the branch circuit.
230/208-volt models may be installed using one of the following electrical subbases:
Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit
20 RAK204D20P
30 RAK204D30P*
Appearance may vary.
*Not approved for use on 7000 BTUmodels.
Electrical subbases provide an enclosure for direct connection or enclosed receptacles. The subbase kit includes the power cord.
Connections of 208 or 230-volt circuits may be with a power supply kit or a junction box kit.
All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations. Codes require the use of an arc fault or leakage current detection device on the power cord except direct connect. Be sure to select the correct cord for your installation.
The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.
Order the following Kit for 230/208-volt direct connection as required:
20 Amp. Large Tandem
15 Amp.
30 Amp.
Branch Circuit and Power Supply Power Unit Amperage Rating Accessory Supply Kit
230/208-volt receptacle configuration.
Branch Circuit and Proper GE Power Cord Unit Amperage Rating with LCDI Device
20 RAK4002A RAK4207
15 RAK3153
30 RAK4002A RAK4307*
20 RAK3203
*Not approved for use on 7000 BTU models.
Skip to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.
*Not approved for use on 7000 BTU models.
Power supply kit · Tandem · Perpendicular

WARNING: Connection of this 265V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electrical Code. Plugging this unit into a building-mounted exposed receptacle is not permitted by code. These models must be installed using the appropriate GE power supply kit for the branch circuit amperage and the electrical resistance heater wattage desired. Use the POWER CONNECTION CHART on page 16 to determine the correct kit required. One of the following installation methods (A or B) must be used.
INSTALLATION If an electrical subbase is not used, direct connection to branch circuit wiring inside the provided junction box must be done in accordance with the following steps. Order the following Kit for 265-volt direct connection as required:
Branch Circuit and Power Unit Amperage Rating Supply Kit
20 RAK5207
30 RAK5307*
A. FOR SUBBASE INSTALLATION Electrical subbase kits are available to provide a flexible enclosure for direct connection.
*Not approved for use on 7000 BTUmodels. Proceed to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.
Branch Circuit and Proper GE Power Unit Amperage Rating Subbase Kit Supply Kit
20 RAK204E20 RAK5202
30 RAK204E30 RAK5302*
*Not approved for use on 7000 BTUmodels.
The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

REMOVE JUNCTION BOX 1. Remove the junction box cover by removing the front two screws. 2. Remove the junction box by removing the top and bottom rear screws. Note how the tabs on the lower left side of the junction box serve to hold the side in place. This will help when the box is being reinstalled.
ATTACH CONDUIT 1. Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box. Leave 6″ of wire free at the end of the conduit to allow connections to be made.
CONNECT THE CORDSET Plug the connector, provided in the Direct Connect Kit, fully into place in the unit mating connector. Be sure the locking tabs at the sides are engaged.
REINSTALL JUNCTION BOX • Reinstall the junction box by engaging the left tabs on the lower right face of the unit, aligning the screw holes at the top and bottom and driving the two screws until secure. Be sure that all wire leads are inside the box and not pinched between the box and the unit. The green insulated ground wire from the unit MUST be connected to the branch circuit ground wire. Make all wire connections by using appropriate UL-listed electrical connectors and techniques (black to black, white to white and green to green).
REINSTALL JUNCTION BOX COVER 1. Carefully tuck all wires and connections back inside the junction box. Be sure there are no loose connections or stray uninsulated wires exposed. 2. Place the junction box cover in place. Replace the two screws removed earlier and tighten securely.

230/208 Volt Power Supply Kits with Current Leakage Wall Plug Heater Wattage Detection Device Configuration Circuit Protective Device @ 230/208 Volts
RAK3153 Tandem 15-Amp Time-Delay Fuse or Breaker 2.55/2.09 KW RAK3203 Perpendicular 20-Amp Time-Delay Fuse or Breaker 3.45/2.82 KW RAK3303* Large Tandem 30-Amp Time-Delay Fuse or Breaker 5.00/4.10 KW
230/208 Volt Heater Wattage Power Supply Kits Circuit Protective Device @ 230/208 Volts
RAK4157 15-Amp Time-Delay Fuse or Breaker 2.55 KW/2.09 KW RAK4207 20-Amp Time-Delay Fuse or Breaker 3.45 KW/2.82 KW RAK4307* 30-Amp Time-Delay Fuse or Breaker 5.00 KW/4.10 KW
265 Volt Heater Wattage Power Supply Kits Circuit Protective Device @ 265 Volts
RAK5157 15-Amp Time-Delay Fuse or Breaker 2.55 KW RAK5207 20-Amp Time-Delay Fuse or Breaker 3.45 KW RAK5307* 30-Amp Time-Delay Fuse or Breaker 5.00 KW
*Not approved for use on 7000 BTUH units.


INSTALL THE WALL CASE AND EXTERIOR GRILLE The RAB71A series or RAB77A4 wall case must be properly installed per instructions packed with the case. • Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out.
PREPARE THE UNIT • Carefully remove shipping tape and foam shipping blocks from the room cabinet, compressor and vent door. There may be multiple blocks and pieces of shipping tape that need to be removed.
Insulated Wall Case This unit is designed to be installed in a GE plastic or an insulated steel wall case. This minimizes condensation from forming on the room side of the case. The RAB71A series wall cases are insulated. Insulation kit RAK901L is available for use with RAB77A4 or existing uninsulated wall cases when needed. NOTE: For installation with a subbase or duct adapter, see the instructions packed with those kits.


3 REPLACE THE ROOM CABINET Reinstall the room cabinet by hooking the top over the rail along the unit top (1), then pushing it in at the bottom (2).
INSTALL THE UNIT INTO THE WALL CASE Slide the unit into the wall case and secure with four screws through the unit flange holes.

Dry Air 25 Series models are designed to improve dehumidification by 25%. Since more moisture will be removed from the air, there is a greater possibility that water will drip from the wall case than with a standard unit. To prevent this water from dripping onto external building walls, we recommend the use of RAD10 Drain Kit.

External Drain See the Installation Instructions in the RAD10 kit.
Type “A” screw for metal case or Type “B” screw for molded case

Internal Drain See the Installation Instructions in the RAD10 kit.
Type “A” screw for metal case or Type “B” screw for molded case

Troubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for service.
Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged. into the outlet.
The power cord is not • Remove the room cabinet and make sure that the firmly attached. yellow connector on the end of the power cord is firmly engaged.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.
The unit is waiting for • This is normal. The Zoneline will start again after the compressor overload it resets. protector to reset.
Power failure. • If power failure occurs, set the mode control to STOP. When power is restored, set the mode control to the desired setting.
The current interrupter • Press the RESETbutton located on the power cord plug device is tripped. or the box near the plug.
Zoneline does not cool Indoor airflow • Make sure there are no curtains, blinds or furniture or heat as it should is restricted. blocking the front of the Zoneline.
Outdoor airflow is • Make sure the rear grille is not restricted. This can restricted or recirculated. cause the unit to cycle off due to the compressor overload protector.
The temp control may • Turn the control to a lower or higher setting. not be set properly. NOTE: The temperature limiter may be limiting the temperature range.
The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.
The room may have • When the Zoneline is first turned on you need to been hot or cold. allow time for the room to cool down or warm up.
Outdoor air is • Set the vent control to the closed position. entering the room.
Burningodoratthestart Dust is on the surface • This can cause a “burning” odor at the beginning of of heating operation of the heating element. the heating operation. This odor should quickly fade.

Problem Possible Causes What To Do
The air is not always The heat pump is not • This is normal. The heat pump will produce warm air cool or hot during producing hot air. but not as hot as air produced when the higher-cost operation electric heat is used.
The Smart Fan Auxiliary • This causes the fan to blow room temperature air Controls may be set to even when the compressor or heater cycles off. continuous fan. The continuous air movement provides better overall temperature control in the cool mode. See Smart Fan – Cooling/Heating on page 5.
The air does not feel The heat pump alone • Use the Electric Heat Option. This turns off the warm enough during produces air that feels heat pump and warms with electric heat only. heating operation cooler than desired. NOTE: Use of this option will result in increased energy consumption.
The unit is not The Smart Fan Auxiliary • See Smart Fan – Cooling/Heating on page 5. blowing out air Controls may be set to cycle.
The electric heating The power cord is not • Remove the room cabinet and make sure that the feature does not work firmly attached. yellow connector on the end of the power cord is firmly engaged.
Temperature display The compressor may • Set the operation control to STOP and then restart flashes have failed. the unit. If the flashing light reappears within 30 minutes, call for service.

Things that are normal.
Normal Operating Sounds
You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
You may hear relays click when the controls cycle on and off or are adjusted to change the room temperature.
Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
The indoor fan runs continuously when the unit is operating in the cooling mode, unless the Smart Fan Auxiliary Control is set to cycle. This will cause the fan to cycle on and off with the compressor. You may also hear a fan noise stop and start.
You may notice a few minutes delay in starting if you try to restart the Zoneline too soon after turning it off or if you adjust the thermostat right after the compressor has shut off. This is due to a built-in restart protector for the compressor that causes a 3-minute delay.
S I L E N C E
During the defrost cycle, both indoor and outdoor fans stop and the compressor will operate in the cooling mode to remove frost from the outdoor coil. After defrost, the unit will restart in electric heat to quickly warm the room to the desired comfort level.
To protect the compressor and prevent short cycling, the unit is designed to run for a minimum of 3 minutes after the compressor starts at any thermostat setting.

Zoneline Warranty.
All warranty service provided by our Factory Service Centers or an authorized Customer Care® technician. To schedule service, on-line, visit us at GEAppliances.com, or call 800.GE.CARES (800.432.2737). For service in Canada, contact Gordon Williams Corp. at 1.888.209.0999. Please have serial number and model number available when calling for service.
Staple your receipt here. Proof of the original purchase date is needed to obtain service
under the warranty.
One Year Any part of the Zoneline which fails due to a defect in materials or workmanship. During this From the date of the limited one-year warranty, GE will also provide, free of charge, all labor and related service to original purchase replace the defective part.
Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator and all From the date of the connecting tubing) which fails due to a defect in materials or workmanship. During this original purchase four-year limited additional warranty, GE will also provide, free of charge, all labor and related service to replace the defective part.
Five Years For the second through the fifth year from the date of original purchase, GE will replace From the date of the certain parts that fail due to a defect in materials or workmanship. Parts covered are fan original purchase motors, switches, thermostats, heater, heater protectors, compressor overload, solenoids, circuit boards, auxiliary controls, thermistors, frost controls, ICR pump, capacitors, varistors and indoor blower bearing. During this four-year limited additional warranty, you will be responsible for any labor or on-site service costs.
I Service trips to your site to teach you how to use
I Failure of the product resulting from modifications
the product. I Improper installation, delivery or maintenance. I If you have an installation problem, or if the air
to the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance. I Failure or damage resulting from corrosion due
conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities. I In commercial locations, labor necessary to move the
to installation in a coastal environment, except for models treated with special factory-applied anti-corrosion protection as designated in the model number. I Damage to product caused by improper power supply
unit to a location where it is accessible for service by an individual technician. I Failure or damage resulting from corrosion due to
voltage, accident, fire, floods or acts of God. I Incidental or consequential damage to personal property
installation in an environment containing corrosive chemicals. I Replacement of fuses or resetting of circuit breakers.
caused by possible defects with this air conditioner. I Damage caused after delivery. I Product not accessible to provide required service.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within the USA and Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your site.
Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province. To know what your legal rights are, consult your local, state or provincial consumer affairs office or your state’s Attorney General.

Consumer Support.

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line.

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year! Or call 800.GE.CARES (800.432.2737) during normal business hours.

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800.TDD.GEAC (800.833.4322).

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800.626.2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park Louisville, KY 40225

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material.