CLAVADORA NEUMÁTICA ALIMENTADA CON ROLLO
PARA REVESTIMIENTOS
CLOUEUSE PNEUMATIQUE À CARTOUCHE POUR REVÊTEMENT

MANUEL D’INSTRUCTIONS ET D’ENTRETIEN
BEFORE OPERATING THIS TOOL, ALL OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS. KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE. IF YOU HAVE ANY QUESTIONS, CONTACT YOUR BOSTITCH REPRESENTATIVE OR DISTRIBUTOR.
ANTES DE OPERAR ESTA HERRAMIENTA, TODOS LOS OPERADORES DEBERÁN ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES. MANTENGA ESTAS INSTRUCCIONES CON LA HERRAMIENTA PARA FUTURA REFERENCIA, SI TIENE ALGUNA DUDA, COMUNÍQUESE CON SU REPRESENTANTE DE BOSTITCH O CON SU DISTRIBUIDOR.
LIRE ATTENTIVEMENT LE PRÉSENT MANUEL AVANT D’UTILISER L’APPAREIL. PRÉTER UNE ATTENTION TOUTE PARTICULIÈRE AUX CONSIGNES DE SÉCURITÉ ET AUX AVERTISSEMENTS. GARDER CE MANUEL AVEC L’OUTIL POUR FUTUR RÉFÉRENCE. SI VOUS AVEZ DES QUESTIONS, CONTACTEZ VOTRE REPRÉSENTANT OU VOTRE CONCESSIONNAIRE BOSTITCH.
STANLEY FASTENING SYSTEMS L.P.


EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.
The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.
CAUTION: Additional Safety Protection will be required in some environments. For example, the working area may include exposure to noise level which can lead to hearing damage. The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area. Some environments will require the use of head protection equipment. When required, the employer and user must ensure that head protection conforming to ANSI Z89.1 is used.
Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.
Do not use supply sources which can potentially exceed 200 P.S.I.G. as tool may burst, possibly causing injury.
The connector on the tool must not hold pressure when air supply is disconnected. If a wrong fitting is used, the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury.
Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle, possibly causing injury.
Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool; 3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area, as accidental actuation may occur, possibly causing injury.
When loading tool: 1.) Never place a hand or any part of body in fastener discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger or depress the trip as accidental actuation may occur, possibly causing injury.
Always handle the tool with care: 1.) Never engage in horseplay; 2.) Never pull the trigger unless nose is directed toward the work; 3.) Keep others a safe distance from the tool while tool is in operation as accidental actuation may occur, possibly causing injury.
The operator must not hold the trigger pulled on contact arm tools except during fastening operation as serious injury could result if the trip accidentally contacted someone or something, causing the tool to cycle.
Keep hands and body away from the discharge area of the tool. A contact arm tool may bounce from the recoil of driving a fastener and an unwanted second fastener may be driven possibly causing injury.
Check operation of the contact arm mechanism frequently. Do not use the tool if the arm is not working correctly as accidental driving of a fastener may result. Do not interfere with the proper operation of the contact arm mechanism.
Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury.
Do not drive fasteners close to the edge of the work piece as the wood may split, allowing the fastener to be deflected possibly causing injury.
When working on air tools note the warnings in this manual and use extra care when evaluating problem tools.

All screws and nuts are metric.
This tool will accept plastic and wire collated coil nails in lengths of 1-1/2” to 3” (38 - 75mm) and shank diameters of .090” to .131” (2.3mm to 3.3mm).
This tool uses a free-flow connector plug, 1/4” N.P.T. The minimum inside diameter should be .200” (5mm). The fitting must be capable of discharging tool air pressure when disconnected from the air supply.
70 to 120 p.s.i.g. (4.8 to 8.3 kg/cm2). Select the operating pressure within this range for best fastener performance.
DO NOT EXCEED THE RECOMMENDED OPERATING PRESSURE.
AIR CONSUMPTION: The N75C requires 5.40 cubic feet per minute (.153 m3) of free air to operate at the rate of 100 nails per minute, at 80 p.s.i. (5.62 kg/cm2). Take the actual rate at which the tool will be run to determine the amount of air required. For instance, if your fastener usage averages 50 nails per minute, you need 50% of the tool’s c.f.m. which is required to operate the tool at 100 nails per minute.
BOSTITCH OFFERS TWO TYPES OF OPERATION FOR THIS SERIES TOOL.
The common operating procedure on “Contact Trip” tools is for the operator to contact the work to actuate the trip mechanism while keeping the trigger pulled, thus driving a fastener each time the work is contacted. This will allow rapid fastener placement on many jobs, such as sheathing, decking and pallet assembly. All pneumatic tools are subject to recoil when driving fasteners. The tool may bounce, releasing the trip, and if unintentionally allowed to recontact the work surface with the trigger still actuated (finger still holding trigger pulled) an unwanted second fastener will be driven.
The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger. This makes accurate fastener placement easier, for instance on framing, toe nailing and crating applications.The Sequential Trip allows exact fastener location without the possibility of driving a second fastener on recoil, as described under “Contact Trip”. The Sequential Trip Tool has a positive safety advantage because it will not accidentally drive a fastener if the tool is contacted against the work – or anything else – while the operator is holding the trigger pulled.
Refer to Operation Instructions on page 8 before proceeding to use this tool.
CONTACT TRIP SEQUENTIAL TRIP Identified by: Identified by: BLACK TRIGGER GRAY TRIGGER

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury. FITTINGS:
Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected from the supply source.
Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm2) working pressure rating or 150 percent of the maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” from the male plug on the tool.
Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE.
A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 kg/cm2) is required to control the operatiing pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 kg/cm2) as tool may fracture or burst, possibly causing injury.
Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.
Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance.
Frequent, but not excessive, lubrication is required for best performance. Oil added through the air line connection will lubricate the internal parts. Use BOSTITCH Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance.
If no airline lubricator is used, add oil during use into the air fitting on the tool once or twice a day. Only a few drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle.
For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of BOSTITCH WINTER FORMULA air tool lubricant or permanent antifreeze (ethylene glycol) as a cold weather lubricant.

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.
The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.

2. Check Adjustment: The nailer must be set for the length of nail to be used. Nails will not feed smoothly if the magazine is not correctly adjusted. The magazine contains an adjustable nail platform on which the nail coil rests. The nail platform can be moved up and down to four nail settings. To change setting twist the post and place into the correct step. Fig.B 1-1/2” (38mm) nails - use 1st step 1-3/4” – 2” (45-50mm) nails - use 2nd step 2-1/4” – 2-3/8” (55-60mm) nails - use 3rd step 2-1/2” – 3” (65-75mm) nails - use 4th step 3. Load the coil of nails: Place the coil of nails over the post in the magazine. Uncoil enough nails to reach the feed pawl. Place the first nail in front of the front tooth on the feed pawl, in the driver channel. The nail heads must be in the slot in the nose. Fig. C and Fig. D


4. Swing cover closed: To aid in the feeding of plastic collated nails the tab on the cover should be repositioned. To do so apply pressure to the top center of the tab and simultaneously apply pressure to the bottom outer edge of the tab until it rests on the top outer brim of the cover. Swing the door/magazine cover closed. Check that the latch engages when released. (If it does not engage, check that the nail heads are in the slot in the nose.)



The DIAL-A-DEPTH™Fastener Control adjustment feature provides close control of the fastener drive depth: from flush with the work surface to shallow or deep countersink. First, set the air pressure for consistent drive in the specific work as described on page 4, then use the DIAL-A-DEPTH™ Fastener Control adjustment to give the desired depth of drive.

The adjustable exhaust deflector can be rotated to any desired position by hand without the use of any tools.

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS
MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.
The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection. BEFORE HANDLING OR OPERATING THIS TOOL:
I. READ AND UNDERSTAND THE WARNINGS CONTAINED IN THIS MANUAL.
II. REFER TO “TOOL SPECIFICATIONS” IN THIS MANUAL TO IDENTIFY THE OPERATING SYSTEM ON YOUR TOOL.
There are two available systems on BOSTITCH pneumatic tools. They are:
OPERATION
on the work surface, WITHOUT PULLING THE TRIGGER. Depress the contact trip until the nose touches the work surface and then pull the trigger to drive a fastener. Do not press the tool against the work with extra force. Instead, allow the tool to recoil off the work surface to avoid a second unwanted fastener. Remove your finger from the trigger after each operation.
trip pointing towards but not touching the work surface. Pull the trigger and then tap the contact trip against the work surface using a bouncing motion. Each depression of the contact trip will cause a fastener to be driven.
The operator must not hold the trigger pulled on contact trip tools except during fastening operation, as serious injury could result if the trip accidentally contacted someone or something, causing the tool to cycle.
Keep hands and body away from the discharge area of the tool. A contact trip tool may bounce from the recoil of driving a fastener and an unwanted second fastener may be driven, possibly causing injury. 2. SEQUENTIAL TRIP OPERATION:
The SEQUENTIAL TRIP MODEL contains a contact trip that operates in conjunction with the trigger to drive a fastener. To operate a sequential trip tool, first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER. Depress the contact trip and then pull the trigger to drive a fastener. As long as the contact trip is contacting the work and is held depressed, the tool will drive a fastener each time the trigger is depressed. If the contact trip is allowed to leave the work surface, the sequence described above must be repeated to drive another fastener.

A. With finger off the trigger, press the contact trip against the work surface.
THE TOOL MUST NOT CYCLE.
B. Hold the tool off the work surface, and pull the trigger.
THE TOOL MUST NOT CYCLE.
C. With the tool off the work surface, pull the trigger. Press the contact trip against the work surface.
THE TOOL MUST CYCLE.
D. Without touching the trigger, press the contact trip against the work surface,
then pull the trigger. THE TOOL MUST CYCLE.
A. Press the contact trip against the work surface, without touching the trigger.
THE TOOL MUST NOT CYCLE.
B. Hold the tool off the work surface and pull the trigger.
THE TOOL MUST NOT CYCLE. Release the trigger. The trigger must return to the trigger stop on the frame.
C. Pull the trigger and press the contact trip against the work surface.
THE TOOL MUST NOT CYCLE.
D. With finger off the trigger, press the contact trip against the work surface. Pull the trigger.
THE TOOL MUST CYCLE.
When working on air tools, note the warnings in this manual and use extra care evaluating problem tools.
BOSTITCH replacement parts are recommended. Do not use modified parts or parts which will not give equivalent performance to the original equipment.
When repairing a tool, make sure the internal parts are clean and lubricated. Use Parker “O”-LUBE or equivalent on all “O”-rings. Coat each “O”-ring with “O”-LUBE before assembling. Use a small amount of oil on all moving surfaces and pivots. After reassembly add a few drops of BOSTITCH Air Tool Lubricant through the air line fitting before testing.
Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of undersize fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent the tool from receiving an adequate volume of air, even though the pressure reading is high. The results will be slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace the air supply from the tool to the supply source for restrictive connectors, swivel fittings, low points containing water and anything else that would prevent full volume flow of air to the tool.

Trigger valve housing leaks air O-ring cut or cracked Replace O-ring
Trigger valve stem leaks air O-ring/seals cut or cracked Replace trigger valve assembly
Frame/nose leaks air Loose nose screws Tighten and recheck
O-ring or Gasket is cut or cracked Replace O-ring or gasket
Bumper cracked/worn Replace bumper
Frame/cap leaks air Damaged gasket or seal Replace gasket or seal
Cracked/worn head valve bumper Replace bumper
Loose cap screws Tighten and recheck
Failure to cycle Air supply restriction Check air supply equipment
Tool dry, lack of lubrication Use BOSTITCH Air Tool Lubricant
Worn head valve O-rings Replace O-rings
Broken cylinder cap spring Replace cylinder cap spring
Head valve stuck in cap Disassemble/Check/Lubricate
Lack of power; slow to cycle Tool dry, lacks lubrication Use BOSTITCH Air Tool Lubricant
Broken cylinder cap spring Replace cap spring
O-rings/seals cut or cracked Replace O-rings/seals
Exhaust blocked Check bumper, head valve spring, muffler
Trigger assembly worn/leaks Replace trigger assembly
Dirt/tar build up on driver Disassemble nose/driver to clean
Cylinder sleeve not seated correctly on bottom bumper Disassemble to correct Head valve dry Disassemble/lubricate Air pressure too low Check air supply equipment
Skipping fasteners; intermittent feed Worn bumper Replace bumper
Tar/dirt in driver channel Disassemble and clean nose and driver
Air restriction/inadequate air flow through quick disconnect socket and plug Replace quick disconnect fittings Worn piston O-ring Replace O-ring, check driver Tool dry, lacks lubrication Use BOSTITCH Air Tool Lubricant
Damaged feed piston spring Replace spring
Low air pressure Check air supply system to tool
Loose canister nose screws Tighten all screws
Fasteners too short for tool Use only recommended fasteners
Bent fasteners Discontinue using these fasteners
Wrong size fasteners Use only recommended fasteners
Leaking head cap gasket Tighten screws/replace gasket
Trigger valve O-ring cut/worn Replace O-ring
Broken/chipped driver Replace driver (check piston O-ring)
Dry/dirty magazine Clean magazine
Fasteners jam in tool Driver channel worn Replace nose/check door
Wrong size fasteners Use only recommended fasteners
Bent fasteners Discontinue using these fasteners
Loose canister/nose screws Tighten all screws
Broken/chipped driver Replace driver
Skipping fasteners; intermittent feed Feed piston dry Add BOSTITCH Air Tool Lubricant in hole in feed piston cover
Feed piston O-rings cracked/worn Replace O-rings/check bumper and spring. Lubricate assembly.
Check Pawl binding Inspect Pawl and spring on door. Must work freely.
Canister bottom not set correctly Set canister bottom for length of nails being used
Broken weld wires in nail coil Remove coil of nails and use another coil
Fasteners jam in tool/canister Wrong size fasteners for tool Use only recommended fasteners/check canisterbottom adjustment
Broken welded wires in nail coil Remove coil of nails and use another coil

BC601 4 oz. Bostitch Air -Tool Lubricant BC602 1 pint Bostitch Air -Tool Lubricant BC603 1 pint Bostitch “Winter-Formula” Air-Tool Lubricant BC604 1 quart Bostitch Air -Tool Lubricant 100679 O-Ring Lube (1lb. can) 851325 Locite Grade 271 (.02 oz.) 851385 Locite Grade 242 (.02 oz.) CNTK1 Kit, Contact Trip Conversion (Black Trigger) TVA6 Trigger Valve Assembly SEQ4 Kit, Sequential Trip Conversion (Gray Trigger) N66C-RK Rebuild Kit – N66C, N66BC, N75C
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.