DS04-27706-2E FUJITSU SEMICONDUCT OR DA T A S H E E T ASSP F or P o wer Supply Applications (Secondar y batter y) DC/DC Con ver ter IC f or Char ging MB3878 ■ ■ ■ ■ DESCRIPTION The MB3878 is a.
MB3878 2 (Continued) • Built-in current detector amplifier with wide in-phase input v oltage range : 0 V to Vcc • In standb y mode, leav e output voltage setting resistor open to pre vent ineffici.
MB3878 3 ■ ■ ■ ■ PIN DESCRIPTION Pin No. Symbol I/O Descriptions 1 − INC2 I Current detection amplifier (Current Amp. 2) input pin. 2 OUTC2 O Current detection amplifier (Current Amp. 2) output pin. 3 + INE2 I Error amplifier (Error Amp. 2) non-inverted input pin.
MB3878 4 ■ ■ ■ ■ BLOCK DIA GRAM + − − + 8 10 13 12 9 + − − + 4 2 24 1 3 × 25 × 25 + + + − 5 20 21 19 − + + + − 11 16 22 17 6 23 14 18 <Current Amp.1> <Error Amp.1> 7 VREF <Current Amp.2> <Error Amp.2> VREF <Error Amp.
MB3878 5 ■ ■ ■ ■ ABSOLUTE MAXIMUM RA GINGS * : The package is mounted on the dual-sided epo xy board (10 cm × 10 cm). W ARNING: Semiconductor de vices can be per manently damaged by application of stress (v oltage, current, temperature , etc.
MB3878 6 ■ ■ ■ ■ ELECTRICAL CHARA CTERISTICS (Ta = + 25 ° C, VCC = 19 V, VCC (O) = 19 V, VREF = 0 mA) * : Standard design v alue. (Continued) Parameter Symbol Pin No. Conditions Value Unit Min Typ Max Reference voltage block (Ref) Output voltage V REF 6 Ta = + 25 ° C 4.
MB3878 7 (Ta = + 25 ° C, VCC = 19 V, VCC (O) = 19 V, VREF = 0 mA) * : Standard design v alue. (Continued) Parameter Symbol Pin No. Conditions Value Unit Min Typ Max Error amplifier block (Error Amp.3) Threshold voltage V TH1 16 FB3 = 2 V, Ta = + 25 ° C 4.
MB3878 8 (Continued) (Ta = + 25 ° C, VCC = 19 V, VCC (O) = 19 V, VREF = 0 mA) * : Standard design v alue Parameter Symbol Pin No. Conditions Value Unit Min Typ Max Current detection amplifier block (Current Amp.1, Current Amp.2) Output voltage V OUTCH 2, 10 4.
MB3878 9 ■ ■ ■ ■ TYPICAL CHARA CTERISTICS (Continued) Ta = + 25 ° C CTL = 5 V 12 10 8 6 4 2 0 0 5 10 15 20 25 Ta = + 25 ° C CTL = 5 V VREF = 0 mA 10 8 6 4 2 0 0 5 10 15 20 25 Ta = + 25 ° C VCC = 19 V CTL = 5 V 10 8 6 4 2 0 0 5 10 15 20 25 30 2.
MB3878 10 (Continued) Ta = + 25 ° C VCC = 19 V CTL = 5 V 1 M 100 k 10 k 10 k 100 k 1 M Ta = + 25 ° C CTL = 5 V RT = 47 k Ω 340 330 320 310 300 290 280 270 260 250 240 0 5 10 15 20 25 VCC = 19 V CTL = 5 V RT = 47 k Ω 340 330 320 310 300 290 280 270 260 250 240 − 40 − 20 0 20 40 60 80 100 VCC = 19 V CTL = 5 V 5.
MB3878 11 (Continued) − + −+ VCC = 19 V Error Amp.1 (Error Amp.2) (3) (5) (4) 2.5 V 10 k Ω 2.4 k Ω 240 k Ω 10 k Ω 5.2 V 1 µ F OUT IN φ A V Ta = + 25 ° C 40 20 0 − 20 − 40 180 90 0 − 90 − 180 1 k 10 k 100 k 1 M 10 M 7 8 9 VCC = 19 V Current Amp.
MB3878 12 ■ ■ ■ ■ FUNCTIONAL DESCRIPTION 1. DC/DC Con ver ter Unit (1) Reference v oltage bloc k (Ref) The ref erence voltage generator uses the v oltage supplied from the VCC ter minal (pin 18) to generate a tem- perature-compensated, stab le voltage (5.
MB3878 13 (7) PWM comparator b lock (PWM Comp.) The PWM comparator circuit is a v oltage-pulse width conv er ter f or controlling the output duty of the error amplifiers (Error Amp .
MB3878 14 ■ ■ ■ ■ SETTING THE CHARGING V OL T A GE The charging v oltage (DC/DC output voltage) can be set b y connecting e xter nal voltage setting resistors (R3, R4) to the -INE3 ter minal.
MB3878 15 ■ ■ ■ ■ A C AD APT OR V OL T A GE DETECTION With an e xter nal resistor connected to the +INE2 ter m inal(pin 3), the IC enters the dynamically-controlled charging mode to reduce the.
MB3878 16 ■ ■ ■ ■ PR OCESSING WITHOUT USE OF THE CS PIN If the soft-star t function is not used, the CS ter minal (pin 22) should be left open.
MB3878 17 ■ ■ ■ ■ APPLICA TION EXAMPLE 1 + − − + 8 10 13 12 A B 9 + − − + 4 2 24 1 3 × 25 × 25 + + + − 5 20 21 19 − + + + − 11 16 22 17 6 23 14 18 <Current Amp.1> <Error Amp.1> 7 VREF <Current Amp.2> <Error Amp.
MB3878 18 ■ ■ ■ ■ P ARTS LIST (f or APPLICA TION EXAMPLE 1) Note VISHA Y SILICONIX : VISHA Y Inter technolog y, Inc. MO T OROLA : Motorola J apan Ltd.
MB3878 19 ■ ■ ■ ■ REFERENCE D A T A 100 98 96 94 92 90 88 86 84 82 80 10 m 100 m 1 10 100 98 96 94 92 90 88 86 84 82 80 0 2 4 6 8 10 12 14 16 18 16 14 12 10 8 6 4 2 0 012345 DCC : Dynamically .
MB3878 20 ■ ■ ■ ■ APPLICA TION EXAMPLE 2 + − − + 8 10 13 12 A B C D 9 + − + − + − − + 4 2 24 1 3 × 25 × 25 + + + − 5 20 21 19 − + + + − 11 16 22 17 6 23 14 18 <Current Amp.1> <Error Amp.1> 7 VREF <Current Amp.
MB3878 21 ■ ■ ■ ■ P ARTS LIST (f or APPLICA TION EXAMPLE 2) Note VISHA Y SILICONIX : VISHA Y Inter technolog y, Inc. MO T OROLA : Motorola J apan Ltd.
MB3878 22 ■ ■ ■ ■ USA GE PRECA UTIONS • Printed cir cuit board gr ound lines should be set up with consideration f or common impedance. • T ake appropriate static electricity measures. • Containers f or semiconductor materials should ha v e anti-static protection or be made of conductive material.
MB3878 23 ■ ■ ■ ■ P A CKA GE DIMENSION 24-pin plastic SSOP (FPT-24P-M03) Note1: Pins width and pins thickness include plating thickness. Note2: * This dimension does not include resin protrusion. Dimensions in mm (inches) C 2001 FUJITSU LIMITED F24018S-c-3-4 7.
MB3878 FUJITSU LIMITED All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Fujitsu MB3878 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Fujitsu MB3878 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Fujitsu MB3878, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Fujitsu MB3878 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Fujitsu MB3878, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Fujitsu MB3878.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Fujitsu MB3878. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Fujitsu MB3878 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.