FR
Friedrich logo
Notice d'utilisation officielle

Friedrich WS16B30A

6 pages·938 KB·Climatiseur·PDF·EN
Friedrich WS16B30A
Table des matières 32 sections THRU-THE-WALL AIR CONDITIONERS · cool only | heat pumps | electric heat · Perfect for new construction, retrofits and remodeling · ANTIMICROBIAL · … AfficherMasquer
Page 1 of the Friedrich WS16B30A user manual — THRU-THE-WALL AIR CONDITIONERS
Page 1 · cliquer pour agrandir
Page 1
Friedrich WS16B30A — THRU-THE-WALL AIR CONDITIONERS diagram (page 1)
Fig. 1

THRU-THE-WALL AIR CONDITIONERS

cool only | heat pumps | electric heat

Friedrich WS16B30A — THRU-THE-WALL AIR CONDITIONERS diagram (page 1)
Fig. 2
Friedrich WS16B30A — THRU-THE-WALL AIR CONDITIONERS diagram (page 1)
Fig. 3
Page 2 of the Friedrich WS16B30A user manual — ANTIMICROBIAL
Page 2 · cliquer pour agrandir
Page 2
Friedrich WS16B30A — Perfect for new construction, retrofits and remodeling diagram (page 2)
Fig. 4 · Perfect for new construction, retrofits and remodeli…

Perfect for new construction, retrofits and remodeling

ANTIMICROBIAL

FILTER

The Most Energy Efficient Solid-side Air Conditioner

Installs in existing 27” sleeves

Friedrich WS16B30A — ANTIMICROBIAL diagram (page 2)
Fig. 5

Cooling only, heat pump & electric heat

  • High efficiency operation saves on energy costs
  • Ideal for thicker wall installations, where side fins don’t fit
  • Residential/commercial applications
  • Easy-to-reach, top mount controls
  • Mounts flush with the exterior wall for a neat appearance
  • Three-speed fan
  • Efficient rotary compressor
  • A high efficiency replacement for 27" sleeves including Fedders A and B*. Sleeve measures 27" W x 16 3/4" H
  • Easy-to-clean filter
Friedrich WS16B30A — ANTIMICROBIAL diagram (page 2)
Fig. 6
  • 24 hour programmable timer
  • Money Saver® setting saves energy by cycling the fan with the compressor
Friedrich WS16B30A — ANTIMICROBIAL diagram (page 2)
Fig. 7
  • Smart Fan auto-adjusts fan speed to maintain desired temperature
Friedrich WS16B30A — ANTIMICROBIAL diagram (page 2)
Fig. 8
Friedrich WS16B30A — ANTIMICROBIAL diagram (page 2)
Fig. 9
Height (inches)16 3/416 3/416 3/4 Width (inches)272727 Depth (inches)16 3/416 3/419 3/4

Units are shown installed in WSC sleeve (sold and shipped separately)

*Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories.

REMOTE CONTROL features · FIVE EnergyStar models

Page 3 of the Friedrich WS16B30A user manual — REMOTE CONTROL
Page 3 · cliquer pour agrandir
Page 3
Friedrich WS16B30A — THRU-THE-WALL units mount flush with diagram (page 3)
Fig. 10 · THRU-THE-WALL units mount flush with

THRU-THE-WALL units mount flush with

exterior walls for a sleek appearance, as well as unobstructed window views. (Wallmaster WSC sleeve shown with architectural grille. Uni-fit grille has different appearance.)

Friedrich WS16B30A — THRU-THE-WALL units mount flush with diagram (page 3)
Fig. 11 · THRU-THE-WALL units mount flush with

Universal Fit for Easy Replacement Chassis installs into existing 26" sleeves

Cooling only & electric heat

Friedrich WS16B30A — Universal Fit for Easy Replacement Chassis installs into existing 26" sleeves diagram (page 3)
Fig. 12 · Universal Fit for Easy Replacement Chassis installs…
  • Rotary compressors provide quiet, dependable performance
  • Auto re-start
  • Washable/reusable filter
  • Six-way air flow control
  • Seacoast protection
  • Stale air exhaust

HEAT/COOL MODELS feature mechanical controls, two cooling speeds, two heating speeds, plus one fan-only setting.

COOLING MODELS feature electronic controls with remote control, Money Saver® setting that saves energy by cycling the fan with the compres- sor and three cooling/three fan-only speeds.

Friedrich WS16B30A — Universal Fit for Easy Replacement Chassis installs into existing 26" sleeves diagram (page 3)
Fig. 13 · Universal Fit for Easy Replacement Chassis installs…

REMOTE CONTROL features (cool only models)

  • 12 hour programmable timer
  • Money Saver® setting saves energy by cycling the fan with the compressor

REMOTE CONTROL

12-HOUR TIMER

MONEY SAVER

FEATURE

Sleeve DimensionsFriedrich USC SleeveGEAmanaWhirlpool/ FeddersFrigidaire Height (inches)15 17/3215 5/815 5/815 3/415 7/16 Width (inches)25 7/8262626 3/425 7/8 Depth (inches)16 23/3216 7/816 7/81518
Friedrich WS16B30A — REMOTE CONTROL diagram (page 3)
Fig. 14

Units are shown without USC sleeve (USC sleeves sold and shipped separately)

TWO EnergyStar models

Page 4 of the Friedrich WS16B30A user manual — THRU-THE-WALL units mount flush with
Page 4 · cliquer pour agrandir
Page 4
Friedrich WS16B30A — THRU-THE-WALL units mount flush with diagram (page 4)
Fig. 15 · THRU-THE-WALL units mount flush with

ROOM AIR CONDITIONER Blocked side vents restrict air flow

SOLID SIDE wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty.

Page 5 of the Friedrich WS16B30A user manual — Installation Accessories (WallMaster only)
Page 5 · cliquer pour agrandir
Page 5

Exterior Grilles

Friedrich WS16B30A — Exterior Grilles diagram (page 5)
Fig. 16 · Exterior Grilles
Friedrich WS16B30A — Exterior Grilles diagram (page 5)
Fig. 17 · Exterior Grilles
Friedrich WS16B30A — Exterior Grilles diagram (page 5)
Fig. 18 · Exterior Grilles
Friedrich WS16B30A — Exterior Grilles diagram (page 5)
Fig. 19 · Exterior Grilles

WSC Sleeve/Standard Grille WSC Sleeve/Optional Architectural Grille, AG

Installation Accessories (WallMaster only)

DK / Drain Kit Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired.

SB / Sub Base Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall.

IDK / Internal Drain Kit New construction applications where a condensate drain system has been built into the wall interior.

BAK / Baffle Adapter Kit Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).

Friedrich WS16B30A — Installation Accessories (WallMaster only) diagram (page 5)
Fig. 20 · Installation Accessories (WallMaster only)
Friedrich WS16B30A — Installation Accessories (WallMaster only) diagram (page 5)
Fig. 21 · Installation Accessories (WallMaster only)

STANDARD GRILLE – Expanded aluminum For use with USC sleeve. (Ships with USC sleeve). *REPLACEMENT GRILLE – High-tech plastic For use on existing sleeves without any grille. (Ships with chassis).

USC Sleeve/Standard Grille USC Sleeve/Replacement Grille*

Friedrich WS16B30A — Installation Accessories (WallMaster only) diagram (page 5)
Fig. 22 · Installation Accessories (WallMaster only)
HeightWidthDepthDepth with FrontMinimum Extension Into RoomMinimum Extension OutsideThru-the-wall Finished Hole HeightWidth MASTER eeve 16 3/4" 15 3/4"27"16 3/4"23"7 1/2"9/16"17 1/4"27 1/4" 26 1/2"21"––––– IT eeve 15 1/2"25 7/8"16 3/4"20 1/2"–1/2"15 3/4"26 1/8" ssis 14 3/8"24"20 1/8"3 3/4"––– ssis 14 3/8"24 5/8"19 5/8"3 1/2"–––
Show 5 more labels / short text on this page
CORRECT Vertical Louvers · INCORRECT Horizontal Louvers · 16 3/4" · Fedders B · 19 3/4”
Page 6 of the Friedrich WS16B30A user manual — Plug Face/ Circuit Rating
Page 6 · cliquer pour agrandir
Page 6

Specifications E nergy S tar ® models

Energy Efficiency

Cooling Capacity

Heating Capacity

Moisture

Room Side Air Circulation

Net Weight

Volts Rated

Cooling

Cooling

Heating

Heating

Ratio

Removal Pints/Hr.

Model

BTU/h

BTU/h

Amps

Watts

Amps

Watts

EER

Lbs.

WALLMASTER WS08B10A 8000 — 115 6.8 762 — — 10.5 1.3 245 93 WS10B10A 10000 — 115 8.7 954 — — 10.5 2.4 245 103 WS14B10A 13500 — 115 12.0 1415 — — 9.5 3.3 295 112 WS10B30A 10000/10000 — 230/208 4.6/5.0 1005/996 — — 10.0/10.0 2.1 260 101 WS13B30B 12500/12000 — 230/208 6.3/6.7 1404/1379 — — 8.9/8.7 3.3 280 109 WS16B30A 15800/15000 — 230/208 7.8/8.5 1756/1705 — — 9.0/8.8 4.2 290 119 WE10B33C 10000/10000 11000/9100 230/208 4.6/5.0 1005/996 16.0/14.7 3550/2950 10.0/10.0 2.1 260 103 WE13B33C 12500/12000 11000/9100 230/208 6.3/6.7 1404/1379 16.0/14.7 3550/2950 8.9/8.7 3.3 280 111 WE16B33C 15800/15000 11000/9100 230/208 7.8/8.5 1756/1705 16.0/14.7 3550/2950 9.0/8.8 4.2 290 121 WY10B33C 10100/9800 8100/7800 230/208 4.6/4.8 1013/976 3.9/4.0 857/821 10.0/10.0 2.5 230 107 WY13B33C 12500/12100 10400/10000 230/208 6.4/6.8 1389/1352 5.4/5.7 1182/1136 9.0/9.0 3.2 280 116 UNI-FIT US08B10A 8000 — 115 7.5 830 — — 9.6 2.2 260 73 US10B10A 9800 — 115 10.2 1110 — — 8.8 3.2 285 78 US10B30A 10000/9800 — 230/208 4.7/5.2 1060/1040 — — 9.4 3.2 285 78 US12B10A 11500 — 115 12.0 1310 — — 8.8 3.8 290 80 US12B30B 11500/11200 — 230/208 6.0/6.4 1310/1270 — — 8.8 3.8 290 80 US14B30A 13000/12600 — 230/208 7.0/7.5 1530/1480 — — 8.5 4.0 300 84 UE08A13B 8000 3850 115 7.5 830 10.7 1230 9.6 2.2 260 73 UE10A33B 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4 3.2 285 78

UE12A33B 11500/11200 11200/9200 230/208 6.0/6.4 1310/1270 15.3/14.0 3500/2900 8.8 3.8 290 80

WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.

WALLMASTER HEAT PUMP HEATING PERFORMANCE Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approxi- mately 35°F. Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating per- formance will be satisfactory. Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.

DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and termi- nated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/2950 watts.

DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.

Plug Face/ Circuit Rating

Friedrich WS16B30A — Plug Face/ Circuit Rating diagram (page 6)
Fig. 23 · Plug Face/ Circuit Rating
WallMaster Model NumberUni-Fit Model NumberCircuit Rating Breaker or T-D FusePlug Face (NEMA#)Wall Outlet Appearance WS08B10A, WS10B10A, WS14B10AUS08B10A, UE08A13B US10B10A, US12B10A125V - 15A 5 - 15P WS10B30A, WS13B30A, WS16B30AUS10B30A, US12B30B, US14B30A250V - 15A 6 - 15P WE10, WE13, WE16 WY10, WY13UE10A33B, UE12A33B250V - 20A 6 - 20P

As an Energy Star® partner, Friedrich Air Conditioning Co. has determined that the selected Energy Star® models ( ) meet the Energy Star® guidelines for energy efficiency.

Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com

TTW-08 Printed in USA

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Friedrich WS16B30A

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Friedrich WS16B30A

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Friedrich WS16B30A manuel PDF

6 pages·938 KB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…