cool only | heat pumps | electric heat




FILTER
The Most Energy Efficient Solid-side Air Conditioner
Installs in existing 27” sleeves

Cooling only, heat pump & electric heat




Units are shown installed in WSC sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories.
REMOTE CONTROL features · FIVE EnergyStar models


exterior walls for a sleek appearance, as well as unobstructed window views. (Wallmaster WSC sleeve shown with architectural grille. Uni-fit grille has different appearance.)

Cooling only & electric heat

HEAT/COOL MODELS feature mechanical controls, two cooling speeds, two heating speeds, plus one fan-only setting.
COOLING MODELS feature electronic controls with remote control, Money Saver® setting that saves energy by cycling the fan with the compres- sor and three cooling/three fan-only speeds.

REMOTE CONTROL features (cool only models)
12-HOUR TIMER
MONEY SAVER
FEATURE

Units are shown without USC sleeve (USC sleeves sold and shipped separately)
TWO EnergyStar models


ROOM AIR CONDITIONER Blocked side vents restrict air flow
SOLID SIDE wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty.





WSC Sleeve/Standard Grille WSC Sleeve/Optional Architectural Grille, AG
DK / Drain Kit Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired.
SB / Sub Base Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall.
IDK / Internal Drain Kit New construction applications where a condensate drain system has been built into the wall interior.
BAK / Baffle Adapter Kit Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).


STANDARD GRILLE – Expanded aluminum For use with USC sleeve. (Ships with USC sleeve). *REPLACEMENT GRILLE – High-tech plastic For use on existing sleeves without any grille. (Ships with chassis).
USC Sleeve/Standard Grille USC Sleeve/Replacement Grille*


Cooling Capacity
Heating Capacity
Moisture
Room Side Air Circulation
Net Weight
Volts Rated
Cooling
Cooling
Heating
Heating
Ratio
Removal Pints/Hr.
BTU/h
BTU/h
Amps
Watts
Amps
Watts
EER
Lbs.
WALLMASTER WS08B10A 8000 — 115 6.8 762 — — 10.5 1.3 245 93 WS10B10A 10000 — 115 8.7 954 — — 10.5 2.4 245 103 WS14B10A 13500 — 115 12.0 1415 — — 9.5 3.3 295 112 WS10B30A 10000/10000 — 230/208 4.6/5.0 1005/996 — — 10.0/10.0 2.1 260 101 WS13B30B 12500/12000 — 230/208 6.3/6.7 1404/1379 — — 8.9/8.7 3.3 280 109 WS16B30A 15800/15000 — 230/208 7.8/8.5 1756/1705 — — 9.0/8.8 4.2 290 119 WE10B33C 10000/10000 11000/9100 230/208 4.6/5.0 1005/996 16.0/14.7 3550/2950 10.0/10.0 2.1 260 103 WE13B33C 12500/12000 11000/9100 230/208 6.3/6.7 1404/1379 16.0/14.7 3550/2950 8.9/8.7 3.3 280 111 WE16B33C 15800/15000 11000/9100 230/208 7.8/8.5 1756/1705 16.0/14.7 3550/2950 9.0/8.8 4.2 290 121 WY10B33C 10100/9800 8100/7800 230/208 4.6/4.8 1013/976 3.9/4.0 857/821 10.0/10.0 2.5 230 107 WY13B33C 12500/12100 10400/10000 230/208 6.4/6.8 1389/1352 5.4/5.7 1182/1136 9.0/9.0 3.2 280 116 UNI-FIT US08B10A 8000 — 115 7.5 830 — — 9.6 2.2 260 73 US10B10A 9800 — 115 10.2 1110 — — 8.8 3.2 285 78 US10B30A 10000/9800 — 230/208 4.7/5.2 1060/1040 — — 9.4 3.2 285 78 US12B10A 11500 — 115 12.0 1310 — — 8.8 3.8 290 80 US12B30B 11500/11200 — 230/208 6.0/6.4 1310/1270 — — 8.8 3.8 290 80 US14B30A 13000/12600 — 230/208 7.0/7.5 1530/1480 — — 8.5 4.0 300 84 UE08A13B 8000 3850 115 7.5 830 10.7 1230 9.6 2.2 260 73 UE10A33B 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4 3.2 285 78
UE12A33B 11500/11200 11200/9200 230/208 6.0/6.4 1310/1270 15.3/14.0 3500/2900 8.8 3.8 290 80
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP HEATING PERFORMANCE Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approxi- mately 35°F. Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating per- formance will be satisfactory. Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and termi- nated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/2950 watts.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.

As an Energy Star® partner, Friedrich Air Conditioning Co. has determined that the selected Energy Star® models ( ) meet the Energy Star® guidelines for energy efficiency.
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
TTW-08 Printed in USA