Table des matières 65 sections 115 Volts US08 US10 US12 230 Volts US10 US12 · Safety Precautions · READ THIS MANUAL · Electrical Data Electrical Data....................5 · … AfficherMasquer
Page 1 of the Friedrich US10 user manual — 115 Volts US08 US10 US12 230 Volts US10 US12
Page 1 · cliquer pour agrandir
Page 1
Friedrich US10 — 115 Volts US08 US10 US12 230 Volts US10 US12 diagram (page 1)
Fig. 1 · 115 Volts US08 US10 US12 230 Volts US10 US12

115 Volts US08 US10 US12 230 Volts US10 US12

Model information can be found on the name plate on the front of the unit. To register your application, complete and mail the enclosed registration card, or register on-line at www.friedrich.com (USA only). For your future convenience, record the model information here.

920-136-01(11/04)

Page 2 of the Friedrich US10 user manual — Electrical Data Electrical Data....................5
Page 2 · cliquer pour agrandir
Page 2

Safety Precautions

Safety Precautions Electrical Data Operating Instructions Parts and Installation Before you call for service...

READ THIS MANUAL

Safety Precautions 3

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the trouble shooting section. First review the trouble shooting section before calling service. Your question may already be answered.

Electrical Data Electrical Data 5

Operating Instructions Controls..............................6 Ventilation Control..............8 Air Direction........................8

  • Contact an authorized Service technician for repair or maintenance of this unit.
  • The air conditioner is not intended for use by young children without supervision.

Care and Maintenance Air Filter Cleaning 9 How to Attach Front Grille to Cabinet 9

Parts 10

Installation 11

How to Install 12

Procedure 13-17

Before you call for service...

Trouble Shooting Tips 18 Normal Operation 18 Abnormal Operation 18

Warranty 19

Page 3 of the Friedrich US10 user manual — WARNING WARNING
Page 3 · cliquer pour agrandir
Page 3

Safety Precautions

Safety Precautions

To prevent injury and property damage, the following instructions must be followed. I Ignoring instructions and incorrectly operating the unit can cause harm or damage.

The seriousness is classified by the following indications.

Friedrich US10 — Safety Precautions diagram (page 3)
Fig. 2 · Safety Precautions

CAUTION : This symbol indicates the possibility of injury or damage to

I Meanings of symbols used in this manual are as shown below.

WARNING WARNING

Plug in the power plug properly.

Do not operate or stop the unit by inserting or pulling out the power plug.

Do not damage or use an unspecified power cord.

  • Otherwise, it will cause electric shock or fire due to heat generation.
  • It will cause electric shock or fire due to heat generation.
  • It will cause electric shock or fire.
  • If the power cord is damaged, it must be replaced by the manufacturer or an authorized service center.

Do not modify power cord length or share the outlet with other appliances.

Do not operate with wet hands or in damp environment.

Do not direct airflow directly at room occupants.

  • It will cause electric shock or fire due to heat generation.
  • It will cause electric shock.
  • This could harm your health.
Page 4 of the Friedrich US10 user manual — Safety Precautions
Page 4 · cliquer pour agrandir
Page 4

Safety Precautions

Friedrich US10 — Safety Precautions diagram (page 4)
Fig. 3 · Safety Precautions

When the air filter is to be removed, do not touch the metal parts of the unit.

When the unit is to be cleaned, switch off, and turn off the breaker.

  • They are sharp and may cause an injury.
  • Water may enter the unit and damage the insulation.
  • Since the fan rotates at high speed during operation, it may cause an injury.

Do not put a pet or house plant where it will be exposed to direct air flow.

  • Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
  • It may cause a fire or damage the cabinet.
Page 5 of the Friedrich US10 user manual — 208/230 VOLT UNITS
Page 5 · cliquer pour agrandir
Page 5

Electrical Data

Electrical Data

115V~ 230V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Electrical Data

USE OF EXTENSION CORDS Because of potential safety hazards, do not use an extension cord.

Use Wall ReceptaclePower Supply Standard 125V, 3-wire grounding receptacle rated 15A, 125V ACUse 15 AMP. time delay fuse or 15 AMP. circuit breaker. Standard 250V, 3-wire grounding receptacle rated 15A, 250V AC Standard 250V, 3-wire grounding receptacle rated 20A, 250V ACUse 20 AMP. time delay fuse or 20 AMP. circuit breaker.

Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.

All wiring should be done in accordance with local electrical codes and regulations. NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician.

I ELECTRICAL SAFETY

208/230 VOLT UNITS

These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged in to a matching, properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.

FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

Page 6 of the Friedrich US10 user manual — AUTO RESTART
Page 6 · cliquer pour agrandir
Page 6

Operating Instructions

Friedrich US10 — Operating Instructions diagram (page 6)
Fig. 4 · Operating Instructions

REMOTE CONTROL SIGNAL RECEIVER

Friedrich US10 — REMOTE CONTROL SIGNAL RECEIVER diagram (page 6)
Fig. 5

TEMPERATURE SETTING

  • Use this button to automatically control the temperature of the room. The temperature can be set within a range of 60 ° F to 86 ° F by increments of 1 ° F.
  • The setting appears in the display.

POWER

  • To turn the air conditioner ON, push this button. To turn the air conditioner OFF, push the button again.
  • This button takes priority over any other button.
  • When you first turn it on, the unit is in cool mode, at High fan speed, and set at a temperature setting of 72 ° F.

Operating Instructions

  • You will usually use shut-off time while you sleep.
  • If unit is running, use Timer to set number of hours until shut-off.
  • For your sleeping comfort, once Time is set, the Temperature setting will raise 2 ° F after 30 min., and once again after another 30 min.
  • Push Timer button to advance setting from 1 Hour ¡ 2 Hours ¡ .... ¡ 12 Hours maximum.

FAN SPEED

  • Every time you push this button, it advances the setting as follows: {High ¡ Low ¡ Med ¡ High}
  • If unit is off, use Timer to set number of hours before unit starts.
  • Push Timer button to advance setting from 1 Hour ¡ 2 Hours ¡ ..... ¡ 12 Hours maximum.

MODE - Push this button to shift mode of operation from COOL ¡ MONEY SAVER ¡ FAN.

- COOL :

  • Fan runs continually for normal cooling operation.

- MONEY SAVER:

  • The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air to determine if cooling is needed. - FAN :
  • Fan-only operation.

AUTO RESTART

When power is restored after an electrical power failure, the unit will begin to run at its previous setting.

Page 7 of the Friedrich US10 user manual — - START TIME
Page 7 · cliquer pour agrandir
Page 7

REMOTE CONTROL

  • POWER
  • To turn the air conditioner ON, push this button. To turn the air conditioner OFF, push the button again.
  • This button takes priority over any other button.
  • When you first turn it on, the unit is in cool mode, High fan speed, Temperature setting at 72 ° F.
  • Auto Restart In the event at a power failure, the unit will run at the previous setting once power returns. TEMPERATURE SETTING
  • Use this button to automatically control the temperature of the room. The temperature can be set within a range of 60 ° F to 86 ° F by increments of 1 ° F.
  • The setting appears in the display.

Operating Instrucitons

FAN SPEED • Every time you push this button it advances the setting as follows: (High ¡ Low ¡ Med ¡ High)

TIMER - SHUT-OFF TIME

  • You will usually use shut-off time while you sleep.
  • If unit is running, use Timer to set number of hours until shut-off.
  • For your sleeping comfort, once Time is set, the Temperature setting will rise 2 ° F after 30 min, and after another 30 min.
  • Push Timer button to advance setting from : 1 Hour ¡ 2 Hours ¡ ..... ¡ 12 Hours maximum .

- START TIME

  • If unit is off, use Timer to set number of hours before unit start.
  • Push Timer button to advance setting from : 1 Hour ¡ 2 Hours ¡ ..... ¡ 12Hours maximum .

MODE - Push this button to shift mode of operation from COOL ¡ MONEY SAVER ¡ FAN. - COOL :

  • Fan runs continually for normal cooling operation. - MONEY SAVER
  • The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed. - FAN :
  • Fan-only operation
Show 4 more labels / short text on this page
Power · Temp · Fan Speed · Timer Mode
Page 8 of the Friedrich US10 user manual — Inserting the Remote Control Batteries
Page 8 · cliquer pour agrandir
Page 8

Additional controls and important information.

Ventilation Control

Push the lever to the "CLOSE" position to cool, heat or recirculate room air only. Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room. This feature is best used in conjunction with the FAN ONLY position.

Air Direction

PULL OPEN / PUSH CLOSE

The direction of air can be controlled by adjusting the horizontal and vertical louvers.

  • HORIZONTAL AIR-DIRECTION CONTROL

The horizontal air direction is adjusted by moving the vertical louver. The lever for the vertical louver is located in the right and left side of the air discharge.

Operating Instructions

  • VERTICAL AIR-DIRECTION CONTROL

The vertical air direction is adjusted by moving the horizontal louver.

Inserting the Remote Control Batteries

  • 1. Remove the cover from the back of the remote controller. 2. Insert two batteries.
  • Be sure that the (+) and ( – ) directions are correct.
  • Be sure that both batteries are new. 3. Reattach cover.
  • Do not use rechargeable batteries. Make sure that both batteries are new.
  • In order to prevent discharge, remove the batteries from the remote control if the air conditioner is not going to be used for an extended period of time Keep the remote control away from extremely hot or humid places. To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight.
Page 9 of the Friedrich US10 user manual — Operating Instrucitons
Page 9 · cliquer pour agrandir
Page 9

Care and Maintenance

TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.

Air Filter Cleaning

The air filter should be checked at least twice a month to see if cleaning is necessary. Trapped particles in the filter will build up and block the airflow. This reduces the cooling capacity and can also cause an accumulation of frost on the cooling coils. If the filter becomes torn or damaged you should replace it immediately. Replacement filters are available from your salesperson, dealer, and authorized customer service centers.

Friedrich US10 — Air Filter Cleaning diagram (page 9)
Fig. 6 · Air Filter Cleaning
1. Open the inlet grille downward by grasping the top outside edges of the inlet grille and pulling it towards you.
2. Remove the air filter from the front grille assembly by pulling the air filter up slightly.
3. Wash the filter using lukewarm water and a mild detergent.
4. Gently shake all excess water from the filter. Make sure the filter is completely dry and replace the filter back into the unit.

Operating Instrucitons

How to Attach Front Grille to Cabinet

The front grille can be removed for cleaning or to check the model and serial numbers. For your safety, you should attach the front grille using the following procedures.

1. Pull down front grille from the cabinet top. 2. Push front grille’s tips toward the cabinet in order to insert front grille’s tabs into the cabinet.
3. Open the inlet grille. 4. Tighten the screw through the front grille into the plate of control box. 5. Close inlet grille.
Friedrich US10 — Operating Instrucitons diagram (page 9)
Fig. 7 · Operating Instrucitons
Friedrich US10 — Operating Instrucitons diagram (page 9)
Fig. 8 · Operating Instrucitons
Page 10 of the Friedrich US10 user manual — 17. REAR GRILLE
Page 10 · cliquer pour agrandir
Page 10

Parts

Learning part name prior to installation will help you understand the installation procedure.

Parts

Friedrich US10 — Parts diagram (page 10)
Fig. 9 · Parts

4 11 13 14 12 15 10 8 9

The Sleeve with the Rear Grille (sold separately)

Friedrich US10 — The Sleeve with the Rear Grille (sold separately) diagram (page 10)
Fig. 10 · The Sleeve with the Rear Grille (sold separately)

1. CABINET

11. EVAPORATOR

2. HORIZONTAL AIR DEFLECTOR (Vertical Louver)

12. CONDENSER

13. COMPRESSOR

3. VERTICAL AIR DEFLECTOR (Horizontal Louver)

14. BASE PAN

15. BRACE

4. AIR DISCHARGE

16. SLEEVE ASSEMBLY (Including Expanded Aluminum Rear grille)

5. FRONT GRILLE

6. INLET GRILLE (Air Intake)

17. REAR GRILLE

7. AIR FILTER

8. CONTROL BOARD

9. BUTTONS

10. POWER CORD

Page 11 of the Friedrich US10 user manual — REQUIRED TOOLS:
Page 11 · cliquer pour agrandir
Page 11

Installation

Remove packing sheet from the back of the sleeve, and packing corner and blue tape from the air conditioner. INSTALLATION REQUIREMENTS

INSTALLATION HARDWARE

If you use an existing wall sleeve, you should measure its dimensions. Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1) Installing the FRIEDRICH USC sleeve ensures optimal performance of the new air conditioner. (FIG. 2)

ITEMNAME OF PARTSQ'TY ➀PLASTIC GRILLE1 ➁VERTICAL INSULATION STRIP1 ➂AROUND INSULATION STRIPS2 ➃HORIZONTAL INSULATION STRIP1 ➄SUPPORT BLOCK2 ➅BAFFLE1 ➆TRIM FRAME2 ➇SHIM2 ➈PLASTIC NUTS AND WASHER SCREWS4 ➉GRILLE REAR1

20-3/32" (511 mm)

14-13/32" (366 mm)

18-15/32"(468 mm)

FIG. 1 Air Conditioner

  • To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
  • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
  • Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.
  • Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.
  • Make sure air conditioner does not fall during installation.

25-7/8" (656 mm)

15-17/32" (394 mm)

16-23/32" (425 mm)

FIG. 2 FRIEDRICH Wall Sleeve

ELECTRICAL SERVICE Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

REQUIRED TOOLS:

  • Tight Fitting gloves
  • Standard screwdriver
  • Phillips screwdriver
  • Pliers
  • Sharp knife
  • 3/8-inch open end wrench or adjustable wrench
  • 1/4-inch hex socket and ratchet
  • Tape measure
  • Electric drill
  • 1/4-inch drill bit
Show 4 more labels / short text on this page
2 Size options · 2 Size options · 24"(610 mm) · aluminum metal grille
Page 12 of the Friedrich US10 user manual — FRONT
Page 12 · cliquer pour agrandir
Page 12

INSTALLATION

Installing the FRIEDRICH USC sleeve ensures optional performances of the unit. If you decide to keep the existing wall sleeve, you have to redirect the louvers at the back of the wall sleeve. Refer to FIG. 8 on p14. The use of pliers is recommended. If you DO NOT redirect, you run the risk of poor performance or premature product failure. This is not covered under the terms of the FRIEDRICH warranty.

Remove old air conditioner from existing wall sleeve.

Clean the interior of an existing sleeve. (Do not disturb seals.)

Wall sleeve must be securely fastened in wall before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.

  • Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.

Prepare the wall sleeve for installation of the unit. If you plan to use your existing wall sleeve, and it is not FRIEDRICH, use procedure B or C below.

ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit. Discard unused parts

ProcedureBrandDepth(inches) A(page 13)FRIEDRICH USC16-23/32 B (pages 14~15)White-Westinghouse Frigidaire Carrier (52F series)16, 17-1/2 or 22 General Electric /Hotpoint16-7/8 Whirlpool17-1/8 or 23 Carrier (51S series)18-5/8 C (pages 16~17)Fedders/Emerson Friedrich WSC16-3/4 or 19-3/4 Emerson/Fedders15
ITEM (inches)Qty. Plastic grille263/4 x 161/21 Vertical insulation strip159/16 x 13/8 x 13/81 Around Insulation Strips671/8 x 13/8 x 25/321 5927/32 x 13/8 x 13/81 Horizontal Insulation Strip237/32 x 13/8 x 13/161 Support Block13/4 x 13/8 x 45/162 Baffle14 x 41/2 x 1/81 Shim1113/16 x 1 x 3/42 Trim Frame2 Washer Screw4 Nuts(Plastic)4 Grille Rear1

Install new unit into wall sleeve.

HOW TO INSTALL

Before installing the unit, identify the existing wall sleeve from the list below.

BrandWall Sleeve Dimensions (inches) WidthHeightDepth White-Westinghouse Frigidaire Carrier (52F series)25-1/215-1/416, 17-1/2 or 22 General Electric /Hotpoint2615-5/816-7/8 Whirlpool25-7/816-1/217-1/8 or 23 Fedders/Emerson2716-3/416-3/4 Friedrich WSC FRIEDRICH USC25-7/815-17/32or 19-3/4 16-23/32 Emerson/Fedders26-3/415-3/415 Carrier (51S Series)25-3/416-7/818-5/8

1" high 3/4" High

UNIT

Shim Shi 6"6"

FRONT

SHIM PLACEMENT UNIT INSTALLATION

Wall Sleeve · 1/4"

Page 13 of the Friedrich US10 user manual — Wall
Page 13 · cliquer pour agrandir
Page 13

PROCEDURE A

Friedrich US10 — PROCEDURE A diagram (page 13)
Fig. 11

If you are using the new sleeve (optionally supplied with your unit),skip to step 3. Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

To assemble trim, snap the tab of each piece into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.

Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressing into the square holes of the rear flanges.Fasten the bracket to the upside of the wall sleeve using the washer screw. The bracket prevents the unit from leaving the sleeve.

Wall

FIG. 5 Fasten the screws and the bracket

Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below.

  • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
  • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
  • Make sure air conditioner does not fall during removal.
  • If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.

9 1/2" 6"

Remove the metal rear grille and replace it with the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates through the unit.

Show 6 more labels / short text on this page
Trim (2 ea) · Bracket Bracket · or · Indoor Outdoor · Around Insulation · Vertical Insulation
Page 14 of the Friedrich US10 user manual — PROCEDURE B
Page 14 · cliquer pour agrandir
Page 14

PROCEDURE B

Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below.

Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 9. The use of pliers is recommended.

Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 12
Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 13

If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

Remove the metal rear grille and replace it with the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates through the unit.

Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 14
Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 15

If the depth of your existing wall sleeve is less than or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according to length "A" in the table below.

Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.Fasten the bracket to the upside of the wall sleeve using the washer screw. The bracket prevents the unit from leaving the sleeve.

Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 16
Friedrich US10 — PROCEDURE B diagram (page 14)
Fig. 17
Page 15 of the Friedrich US10 user manual — Assemble trim as described in Step 6, Procedure A. 9
Page 15 · cliquer pour agrandir
Page 15

PROCEDURE B CONTINUED

Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 15. Slide the baffle into slots of the support blocks.

(7 3/32")

Install the new unit into the wall sleeve.

Assemble trim as described in Step 6, Procedure A. 9

  • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
  • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
  • Make sure air conditioner does not fall during removal.
  • If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.

Wall · Wall Sleeve Baffle · Front Support Block

Page 16 of the Friedrich US10 user manual — PROCEDURE C
Page 16 · cliquer pour agrandir
Page 16

PROCEDURE C

Remove the backing from the Horizontal Insulation strip 237/32 x 13/8 x 13/16 and attach that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 5927/32 x 13/8 x 13/8 and attach that to the inside front of the sleeve as shown below.

Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 16. The use of pliers is recommended.

Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 18
Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 19

If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1/2" wide and 15-1/2" high or to the sleeve dimensions. Place the plastic grille to the inside of the wall sleeve at the rear flange.

If the depth of your existing sleeve is less than or equal to 18”, skip to step 7. Otherwise, cut the baffles and the support blocks according to Length "A" in the table below.

Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 20
Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 21

Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 21. Slide the baffle into slots of the support blocks

Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges. Fasten the bracket to the upside of the wall sleeve using the washer screw. The bracket prevents the unit from leaving the sleeve.

Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 22
Friedrich US10 — PROCEDURE C diagram (page 16)
Fig. 23
Page 17 of the Friedrich US10 user manual — PROCEDURE C CONTINUED
Page 17 · cliquer pour agrandir
Page 17

PROCEDURE C CONTINUED

To achieve rearward slope for unit draining, remove the backing from the 1113/16" shim strips and attach them as shown below in Fig. 23. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve.

  • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
  • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
  • Make sure air conditioner does not fall during removal.
  • If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.
Friedrich US10 — PROCEDURE C CONTINUED diagram (page 17)
Fig. 24

Remove the metal rear grille and replace it with the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates through the unit.

Friedrich US10 — PROCEDURE C CONTINUED diagram (page 17)
Fig. 25

Install the new unit into the wall sleeve

Assemble trim as described in Step 6, Procedure A.

Page 18 of the Friedrich US10 user manual — Problem Possible Causes What To Do
Page 18 · cliquer pour agrandir
Page 18

Before you call for service...

Trouble Shooting Tips

Troubleshooting Tips Save Time and Money! Review the chart below first and you may not need to call for service.

Normal Operation

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
  • The fan may run even when the compressor does not.

Abnormal Operation

Problem Possible Causes What To Do

I The air conditioner is

  • Make sure the air conditioner plug is pushed completely into the outlet.

unplugged.

I The fuse is blown/circuit

  • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.

Air conditioner does not start

breaker is tripped.

I Power failure.

  • If power failure occurs, turn the mode control to OFF . When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

I Airflow is restricted.

  • Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.

I The THERMOSTAT may

  • Push temperature setting button to the coolest temperature setting 60.

not be set high enough.

Air conditioner does not cool as it should

I The air filter is dirty.

  • Clean the filter at least every 2 weeks. See the operating instructions section.

I The room may have been

  • When the air conditioner is first turned on, you need to allow time for the room to cool down.

hot.

I Cold air is escaping.

  • Check for open furnace floor registers and cold air returns.
  • Set the air conditioner's vent to the closed position.

Before you call for service...

I Cooling coils have iced up.

  • See Air Conditioner Freezing Up below.

I Ice blocks the air flow and

  • Set the mode control at Med Fan or High Cool with the thermostat towards the left.

Air conditioner freezing up

stops the air conditioner from cooling the room.

Page 19 of the Friedrich US10 user manual — SECOND THROUGH FIFTH YEAR
Page 19 · cliquer pour agrandir
Page 19

Friedrich Air Conditioning-Co.

P.O. Box 1540 San Antonio, TX 78295-1540

THRU-THE-WALL LIMITED WARRANTY

FIRST YEAR

ANY PART: If any Part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from the date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase.

SECOND THROUGH FIFTH YEAR

SEALED REFRIGERANT SYSTEM: If the sealed refrigeration system (defined for this purpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within Sixty months from the date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.

APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to:

1. Air filters or fuses. 2. Products on which the model and serial numbers have been removed. 3. Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.

OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.

LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.

All service calls for explaining the operation of this product will be the sole responsibility of the consumer.

All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made.

In case of questions regarding the provisions of this warranty, the English version will govern.

(210) 357-4400 · Revised (11/04)

Page 20 of the Friedrich US10 user manual — Memo
Page 20 · cliquer pour agrandir
Page 20

Memo

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Air conditioner does not startI The air conditioner is unplugged.• Make sure the air conditioner plug is pushed completely into the outlet. p.18
Air conditioner does not startI The fuse is blown/circuit breaker is tripped.• Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. p.18
Air conditioner does not startI Power failure.• If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. p.18
Air conditioner does not cool as it shouldI Airflow is restricted.• Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. p.18
Air conditioner does not cool as it shouldI The THERMOSTAT may not be set high enough.• Push temperature setting button to the coolest temperature setting 60. p.18
Air conditioner does not cool as it shouldI The air filter is dirty.• Clean the filter at least every 2 weeks. See the operating instructions section. p.18
Air conditioner does not cool as it shouldI The room may have been hot.• When the air conditioner is first turned on, you need to allow time for the room to cool down. p.18
Air conditioner does not cool as it shouldI Cold air is escaping.• Check for open furnace floor registers and cold air returns. • Set the air conditioner's vent to the closed position. p.18
Air conditioner does not cool as it shouldI Cooling coils have iced up.• See Air Conditioner Freezing Up below. p.18
Air conditioner freezing upI Ice blocks the air flow and stops the air conditioner from cooling the room.• Set the mode control at Med Fan or High Cool with the thermostat towards the left. p.18

Poser une question sur : Friedrich US10

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Friedrich US10

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Friedrich US10 manuel PDF

60 pages·3.1 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…